Tripping Overvoltages in HV Transmission Networks Equipped with Shunt Reactors

被引:0
|
作者
Ciontu, M. [1 ]
Rusinaru, D. [1 ]
Mircea, I. [1 ]
机构
[1] Univ Craiova, Dept Energy, RO-200440 Craiova, Romania
关键词
compensation reactor; current chopping; high-voltage networks; transitory overvoltages;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Last years meant for Romanian power system huge efforts for increasing of its reliability and stability. A national program sustained financially a large-scale upgrading process of power system components. In this paper the authors present the results of an analysis regarding operation of different versions of equipments included in a RV substation. The performed tests outlined the dependency between the chopping current and the overvoltages rising due to switching-off operation of a shunt reactor in the presence of different types of circuit breakers. Further decisions about upgrading the substation components were based on these test results.
引用
收藏
页码:1046 / 1050
页数:5
相关论文
共 50 条
  • [31] Power systems and electric networks: The speed of response of controlled shunt reactors
    Belyaev A.N.
    Smolovik S.V.
    Power Technology and Engineering, 2014, 48 (02) : 153 - 156
  • [32] Analysis of Leakage Inductances in Shunt Reactors: Application to High Voltage Transmission Lines
    Tu Pham Minh
    Hung Bui Duc
    Vuong Dang Quoc
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2022, 12 (03) : 8488 - 8491
  • [33] A novel adaptive auto-reclosing scheme for transmission lines with shunt reactors
    Xie, Xing
    Huang, Chun
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 171 : 47 - 53
  • [34] Analysis of Natural-frequency Components in Parallel Transmission Lines with Shunt Reactors
    Chen, Wenzhe
    Hao, Zhiguo
    Dang, Yiqi
    Liu, Chang
    Zhou, Zexin
    Du, Dingxing
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 1480 - 1485
  • [35] Identification of permanent fault at transmission lines with shunt reactors based on waveform correlation
    Wang, H. (huifangwang@zju.edu.cn), 2013, Automation of Electric Power Systems Press (37):
  • [36] NOVEL DESIGNS IN DISTANCE PROTECTION FOR HV TRANSMISSION NETWORKS - THE MICROMHO SCHEME
    WELLER, GC
    CHEETHAM, WJ
    GEC-JOURNAL OF SCIENCE & TECHNOLOGY, 1983, 49 (01): : 3 - 12
  • [37] Identification of three-phase permanent or temporary fault at transmission lines with shunt reactors
    Li, Yong-Li
    Li, Bo-Tong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (01): : 82 - 90
  • [38] Transient analysis model for incomplete phase operation of EHV transmission line with shunt reactors
    Lin, Jun
    Xiong, Qixin
    Zhu, Jing
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (02): : 48 - 52
  • [39] Fundamentals of Intelligent Automatic Reclosing of Long-Distance Transmission Lines with Shunt Reactors
    Ivanov N.G.
    Naumov V.A.
    Antonov V.I.
    Kadyshev E.N.
    Russian Electrical Engineering, 2019, 90 (08): : 558 - 564
  • [40] Single-phase Adaptive Reclosure for EHV and UHV Transmission Lines with Shunt Reactors
    Shao Wenquan
    Song Guobing
    Jiale, Suonan
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,