Tripping Overvoltages in HV Transmission Networks Equipped with Shunt Reactors

被引:0
|
作者
Ciontu, M. [1 ]
Rusinaru, D. [1 ]
Mircea, I. [1 ]
机构
[1] Univ Craiova, Dept Energy, RO-200440 Craiova, Romania
来源
2009 IEEE BUCHAREST POWERTECH, VOLS 1-5 | 2009年
关键词
compensation reactor; current chopping; high-voltage networks; transitory overvoltages;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Last years meant for Romanian power system huge efforts for increasing of its reliability and stability. A national program sustained financially a large-scale upgrading process of power system components. In this paper the authors present the results of an analysis regarding operation of different versions of equipments included in a RV substation. The performed tests outlined the dependency between the chopping current and the overvoltages rising due to switching-off operation of a shunt reactor in the presence of different types of circuit breakers. Further decisions about upgrading the substation components were based on these test results.
引用
收藏
页码:1046 / 1050
页数:5
相关论文
共 50 条
  • [21] Static stability of long transmission lines with controllable shunt reactors
    Maslennikov, V.A.
    Ustinov, S.M.
    Izvestiya Akademii Nauk. Energetika, 1995, (01): : 58 - 65
  • [22] An Adaptive Reclosure Scheme for Parallel Transmission Lines With Shunt Reactors
    Lin, Da
    Wang, Huifang
    Lin, Dongyang
    He, Benteng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (06) : 2581 - 2589
  • [23] Design of the Internal Fuse Dimension for HV Shunt Capacitor in UHV Transmission Projects
    Wang, Zijian
    Wei, Liqiang
    Yan, Fei
    Wu, Yongli
    Wang, Zichen
    Ma, Yanfeng
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (06) : 2229 - 2240
  • [24] Study of Overvoltages Due to Single Phase Defects in Networks With Insulated Neutral and Shunt Breaker
    Marin, Ion
    Ursu, Doru
    Mircea, Paul-Mihai
    Ciontu, Marian
    Mircea, Ion
    2022 IEEE 20TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, PEMC, 2022, : 143 - 149
  • [25] Simulation and Analysis of the Effect of Single-Pole Auto-reclosing on HV Transmission Lines Switching Overvoltages
    Abbasi, Ehsan
    Seyedi, Heresh
    Strunz, Kai
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1292 - +
  • [26] RELATION BETWEEEN ANODE REACTORS AND OVERVOLTAGES OF HIGH-VOLTAGE THYRISTOR VALVES FOR HVDC TRANSMISSION
    SOGAWA, T
    OHNO, Y
    HORIGOME, T
    ELECTRICAL ENGINEERING IN JAPAN, 1970, 90 (05) : 25 - &
  • [27] Utility Experience of Commissioning Controlled Switching Devices on Transmission Shunt Reactors
    Cowhey, Eoin
    Kearns, Niall
    O'Donovan, Michael
    Connell, Joe
    2017 52ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2017,
  • [28] Improved digital algorithm for adaptive reclosing for transmission lines with shunt reactors
    Luo, Xunhua
    Huang, Chun
    Jiang, Yaqun
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (09) : 2066 - 2070
  • [29] Phenomena and Mechanism Analysis on Overvoltages Caused by 40.5-kV Vacuum Circuit Breakers Switching Off Shunt Reactors
    Du, Ning
    Guan, Yonggang
    Zhang, Jingsheng
    Niu, Jirong
    Yao, Shuhua
    Xu, Guozheng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2102 - 2110
  • [30] Transient power frequency overvoltages transferred to low voltage networks from the EPR of HV and MV transformer stations
    Varju, Gyoergy
    Ladanyi, Jozsef
    7TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND ELECTROMAGNETIC ECOLOGY, PROCEEDINGS, 2007, : 32 - 35