129I AMS at 0.5 MV tandem accelerator

被引:26
|
作者
Alfimov, Vasily [1 ]
Synal, Hans-Arno [1 ]
机构
[1] Swiss Fed Inst Technol, Lab Ion Beam Phys, CH-8093 Zurich, Switzerland
关键词
Iodine-129; Accelerator mass spectrometry (AMS); Compact-size AMS; BRINES; CL-36;
D O I
10.1016/j.nimb.2009.10.026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The I-129 measurement program has been established at the 0.5 MV 'Tandy' accelerator of the PSI/ETH Zurich AMS facility. This development was made possible by using a SiN window instead of Mylar one in a gas ionization detector. The setting up of the I-129 measurement at Tandy is simple, the acquired performance is stable and reliable, and the quality of results is equal to or better than at our larger EN-tandem. With this setup, high sample throughput, which is required in many I-129 studies, can be easily achieved. The measurements are performed in the +3 charge state. At this charge state the major difficulty in the I-129(+3) identification is caused by a highly abundant 43(+1) (m = 43, q = +1) molecule interference. This is a positive molecular ion, because its intensity reduces exponentially with an increase in gas stripper pressure. We conclude that this molecule is (AlO+)-Al-27-O-16 (m/q = 43/1 = 129/3) and comes from the break-up of (Al2O3 + Al)(-) (m = 129) precursor at the terminal: (Al2O3 + Al)(-) -> (AlO+)-Al-27-O-16. The expected isobaric interferences Ca-43(+1) and Sr-86(+2), which also originate from the break-up of molecules in the stripper, were found to be low and do not disturb the I-129(+3) measurements. The best repeatable performance with our standard sample material was achieved at 0.14 mu g/cm(2) Ar gas stripper pressure with machine blanks showing similar to 6 x 10(-14) normalized I-129/I ratio and 9% transmission through the accelerator. However, high (AlO+)-Al-27-O-16 molecular rates were observed from the user samples, and in order to destroy these molecules we had to increase the stripper pressure to similar to 0.22 mu g/cm(2). This increase in the stripper pressure degraded the machine blank values to similar to 9 x 10(-14) and reduced transmission to 8%. Nevertheless, the achieved measurement conditions are sufficient for measurement of nearly all I-129 samples that have been submitted to PSI/ETH over the last few years. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:769 / 772
页数:4
相关论文
共 50 条
  • [41] Extraction and AMS measurement of carrier free 129I/127I from seawater
    Yiou, F
    Raisbeck, G
    Imbaud, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 223 : 412 - 415
  • [42] 129I的小型化AMS测量技术研究
    胡畔
    何明
    赵庆章
    庞义俊
    龚杰
    包轶文
    游曲波
    李康宁
    苏胜勇
    胡跃明
    同位素, 2020, 33 (04) : 199 - 206
  • [43] Analysis and environmental application of 129I at the Xi'an Accelerator Mass Spectrometry Center
    Zhou, Weijian
    Chen, Ning
    Hou, Xiaolin
    Zhang, Luyuan
    Liu, Qi
    He, Chaohui
    Fan, Yukun
    Luo, Maoyi
    Zhao, Yaolin
    Wang, Zhiwen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 294 : 147 - 151
  • [44] 129I measurements in lake water for an estimate of regional 129I depositions
    Reithmeier, H.
    Lazarev, V.
    Ruehm, W.
    Nolte, E.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2007, 376 (1-3) : 285 - 293
  • [45] AMS测量海水129I的气载分离制样
    王荣元
    刘广山
    姜山
    谢林波
    邓春梅
    应用海洋学学报, 2020, 39 (01) : 130 - 135
  • [46] 129I的紧凑型AMS测量技术研究
    张文慧
    赵庆章
    何明
    修诚利
    李康宁
    包轶文
    郭巍
    李建良
    苏胜勇
    游曲波
    原子核物理评论, 2023, 40 (04) : 560 - 565
  • [47] Isotope-selective laser photodetachment for 129I accelerator mass spectrometry
    Tone Takahashi
    Hideki Tomita
    Motoi Nakayama
    Yoshitaka Adachi
    Volker Sonnenschein
    Tetsuo Iguchi
    Klaus Wendt
    Hyperfine Interactions, 2013, 216 : 133 - 138
  • [48] Isotope-selective laser photodetachment for 129I accelerator mass spectrometry
    Takahashi, Tone
    Tomita, Hideki
    Nakayama, Motoi
    Adachi, Yoshitaka
    Sonnenschein, Volker
    Iguchi, Tetsuo
    Wendt, Klaus
    HYPERFINE INTERACTIONS, 2013, 216 (1-3): : 133 - 138
  • [49] Extraction of microgram quantities iodine for 129I/127I AMS measurements in marine sediments
    Fitoussi, C
    Raisbeck, G
    Lunney, D
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A718 - A718
  • [50] IODINE EXTRACTION FROM PETROLEUM FOR ANALYSIS OF 129I/127I RATIOS BY AMS.
    Tullai, Sharon
    Tubbs, Laura Ellen
    Fehn, Udo
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1987, B29 (1-2) : 383 - 386