The I-129 measurement program has been established at the 0.5 MV 'Tandy' accelerator of the PSI/ETH Zurich AMS facility. This development was made possible by using a SiN window instead of Mylar one in a gas ionization detector. The setting up of the I-129 measurement at Tandy is simple, the acquired performance is stable and reliable, and the quality of results is equal to or better than at our larger EN-tandem. With this setup, high sample throughput, which is required in many I-129 studies, can be easily achieved. The measurements are performed in the +3 charge state. At this charge state the major difficulty in the I-129(+3) identification is caused by a highly abundant 43(+1) (m = 43, q = +1) molecule interference. This is a positive molecular ion, because its intensity reduces exponentially with an increase in gas stripper pressure. We conclude that this molecule is (AlO+)-Al-27-O-16 (m/q = 43/1 = 129/3) and comes from the break-up of (Al2O3 + Al)(-) (m = 129) precursor at the terminal: (Al2O3 + Al)(-) -> (AlO+)-Al-27-O-16. The expected isobaric interferences Ca-43(+1) and Sr-86(+2), which also originate from the break-up of molecules in the stripper, were found to be low and do not disturb the I-129(+3) measurements. The best repeatable performance with our standard sample material was achieved at 0.14 mu g/cm(2) Ar gas stripper pressure with machine blanks showing similar to 6 x 10(-14) normalized I-129/I ratio and 9% transmission through the accelerator. However, high (AlO+)-Al-27-O-16 molecular rates were observed from the user samples, and in order to destroy these molecules we had to increase the stripper pressure to similar to 0.22 mu g/cm(2). This increase in the stripper pressure degraded the machine blank values to similar to 9 x 10(-14) and reduced transmission to 8%. Nevertheless, the achieved measurement conditions are sufficient for measurement of nearly all I-129 samples that have been submitted to PSI/ETH over the last few years. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:769 / 772
页数:4
相关论文
共 50 条
  • [31] Transmutation of 129I using an accelerator-driven system
    Nishihara, K
    Takano, H
    NUCLEAR TECHNOLOGY, 2002, 137 (01) : 47 - 59
  • [32] Research on 129I measurement with 300 kV AMS system at CIAE
    Gong Jie
    He Ming
    Zhao Qingzhang
    Hu Pan
    Pang Yijun
    Bao Yiwen
    You Qubo
    Li Kangning
    Su Shengyong
    Hu Yueming
    Wu Shaoyong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 465 : 31 - 36
  • [33] Development of 129I-AMS system at MALT and measurements of 129I concentrations in several Japanese soils
    Matsuzaki, Hiroyuki
    Muramatsu, Yasuyuki
    Kato, Kazuhiro
    Yasumoto, Masaru
    Nakano, Chuichiro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 259 (01): : 721 - 726
  • [34] Accurate determination of 129I concentrations and 129I/137Cs ratios in spent nuclear resins by Accelerator Mass Spectrometry
    Nottoli, Emmanuelle
    Bienvenu, Philippe
    Labet, Alexandre
    Bourles, Didier
    Arnold, Maurice
    Bertaux, Make
    APPLIED RADIATION AND ISOTOPES, 2014, 86 : 90 - 96
  • [35] 36Cl-AMS measurements with 3-MV tandem accelerator
    WANG Huijuan
    GUAN Yongjing
    ZHANG Wei
    JIANG Shan
    Ming He
    NuclearScienceandTechniques, 2013, 24 (01) : 24 - 27
  • [36] 36Cl-AMS measurements with 3-MV tandem accelerator
    Wang Huijuan
    Guan Yongjing
    Zhang Wei
    Jiang Shan
    Ming He
    NUCLEAR SCIENCE AND TECHNIQUES, 2013, 24 (01)
  • [37] Comparison of two methods to determine 129I in charcoal cartridge samples by AMS
    Francisco, B. B. A.
    Bergl, R.
    Zhao, X. -L.
    Cornett, R. J.
    Kieser, W. E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 466 (466): : 47 - 51
  • [38] 环境中人造129I的AMS方法测定
    蒋崧生
    何明
    谢运棉
    姜山
    武绍勇
    质谱学报, 1999, (Z1) : 127 - 128
  • [39] Accelerator mass spectrometry as a powerful tool for the determination of 129I in rainwater
    López-Gutiérrez, JM
    Synal, HA
    Suter, M
    Schnabel, C
    García-León, M
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 81 - 85
  • [40] Accelerator Mass Spectrometry of 129I towards its lower limits
    Vockenhuber, Christof
    Casacuberta, Nuria
    Christl, Marcus
    Synal, Hans-Arno
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 361 : 445 - 449