Improved performances of electrodes based on Cu2+-loaded copper hexacyanoferrate for hydrogen peroxide detection

被引:35
|
作者
Guadagnini, Lorella [1 ]
Tonelli, Domenica [1 ]
Giorgetti, Marco [1 ]
机构
[1] Univ Bologna, Dept Phys & Inorgan Chem, INSTM, UdR Bologna, I-40136 Bologna, Italy
关键词
Hydrogen peroxide; Copper hexacyanoferrate; Copper intercalation; Chronoamperometry; GC electrode; PHOTOINDUCED MAGNETIZATION; SOLID-STATE; IRON; NANOPARTICLES; STABILITY; IDENTITY; SENSOR; FILMS;
D O I
10.1016/j.electacta.2010.04.019
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Copper hexacyanoferrate thin films were potentiodynamically deposited on glassy carbon electrodes and employed for the chronoamperometric detection of hydrogen peroxide at 0.0 V vs. SCE. A new experimental procedure based on the intercalation of copper ions inside the structure of the films led to sensors with improved performances. The modified electrode displayed an increased sensitivity to hydrogen peroxide detection together with a wider linear response range and a lower detection limit. Furthermore, even if the electrode response decreased with use, the initial activity could be restored by performing a new intercalation procedure. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5036 / 5039
页数:4
相关论文
共 50 条
  • [41] Catalytic hydroxylation of 2,3,6-trimethylphenol with hydrogen peroxide over copper hydroxyphosphate(Cu2(OH)PO4)
    Meng, XJ
    Sun, ZH
    Lin, S
    Yang, M
    Yang, XY
    Sun, JM
    Jiang, DZ
    Xiao, FS
    Chen, SY
    [J]. APPLIED CATALYSIS A-GENERAL, 2002, 236 (1-2) : 17 - 22
  • [42] Cu/Cu2O nanoparticles modified Ti3C2 MXene with in-situ formed TiO2-X for detection of hydrogen peroxide
    Li, Quan
    Wang, Xing
    Chen, Lei
    Liu, Xin
    Ma, Jingjing
    Wang, Liang
    Wang, Wentai
    [J]. CERAMICS INTERNATIONAL, 2023, 49 (06) : 9632 - 9641
  • [43] Accumulation of Cu(II) cations in poly(3,4-ethylenedioxythiophene) films doped by hexacyanoferrate anions and its application in Cu2+-selective electrodes with PVC based membranes
    Ocypa, M
    Michalska, A
    Maksymiuk, K
    [J]. ELECTROCHIMICA ACTA, 2006, 51 (11) : 2298 - 2305
  • [44] Electrochemical Sensor for Detection of Hydrogen Peroxide Based on Cu-doped ZIF-8 material modified with Chitosan and Cytochrome C
    Yao, Hui
    Zhang, Wan-ting
    Yan, Ting-yu
    Li, Xiao-qin
    Wang, Xiao-feng
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (05):
  • [45] Non-enzymatic detection of hydrogen peroxide based on Fenton-type reaction on poly(azure A)-chitosan/Cu modified electrode
    Liu, Tong
    Luo, Yiqun
    Wang, Wen
    Kong, Liyan
    Zhu, Jiaming
    Tan, Liang
    [J]. ELECTROCHIMICA ACTA, 2015, 182 : 742 - 750
  • [46] Hydrothermal deposition of CuO/rGO/Cu2O nanocomposite on copper foil for sensitive nonenzymatic voltammetric determination of glucose and hydrogen peroxide
    Chongjun Zhao
    Xian Wu
    Pengwei Li
    Chunhua Zhao
    Xiuzhen Qian
    [J]. Microchimica Acta, 2017, 184 : 2341 - 2348
  • [47] Highly improved electrochemical hydrogen storage performances of the Nd-Cu-added Mg2Ni-type alloys by melt spinning
    Zhang, Yanghuan
    Li, Can
    Cai, Ying
    Hu, Feng
    Liu, Zhuocheng
    Guo, Shihai
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2014, 584 : 81 - 86
  • [48] Hydrothermal deposition of CuO/rGO/Cu2O nanocomposite on copper foil for sensitive nonenzymatic voltammetric determination of glucose and hydrogen peroxide
    Zhao, Chongjun
    Wu, Xian
    Li, Pengwei
    Zhao, Chunhua
    Qian, Xiuzhen
    [J]. MICROCHIMICA ACTA, 2017, 184 (07) : 2341 - 2348
  • [49] Impact of gas diffusion layer architecture on the performances of Cu-based electrodes for CO2 electroreduction to ethylene in flow reactors
    Etzi, Marco
    Dangbegnon, Julien
    Chiodoni, Angelica
    Pirri, Candido F.
    [J]. JOURNAL OF CO2 UTILIZATION, 2024, 83
  • [50] Highly sensitive detection of hydrogen peroxide based on nanoporous Fe2O3/CoO composites
    Wang, Jinping
    Gao, Hua
    Sun, Fenglei
    Hao, Qin
    Xu, Caixia
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 42 : 550 - 555