A new measurement method of coatings thickness based on lock-in thermography

被引:31
|
作者
Zhang, Jin-Yu [1 ]
Meng, Xiang-bin [1 ]
Ma, Yong-chao [1 ]
机构
[1] Xian Res Inst Hightech, 2 Tongxin Rd, Xian 710025, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Functional coatings; Coatings thickness measurement; Lock-in thermography; Infrared thermal wave non-destructive testing; INSPECTION;
D O I
10.1016/j.infrared.2016.04.028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Coatings have been widely used in modern industry and it plays an important role. Coatings thickness is directly related to the performance of the functional coatings, therefore, rapid and accurate coatings thickness inspection has great significance. Existing coatings thickness measurement method is difficult to achieve fast and accurate on-site non-destructive coatings inspection due to cost, accuracy, destruction during inspection and other reasons. This paper starts from the introduction of the principle of lock-in thermography, and then performs an in-depth study on the application of lock-in thermography in coatings inspection through numerical modeling and analysis. The numerical analysis helps explore the relationship between coatings thickness and phase, and the relationship lays the foundation for accurate calculation of coatings thickness. The author sets up a lock-in thermography inspection system and uses thermal barrier coatings specimens to conduct an experiment. The specimen coatings thickness is measured and calibrated to verify the quantitative inspection. Experiment results show that the lock-in thermography method can perform fast coatings inspection and the inspection accuracy is about 95%. Therefore, the method can meet the field testing requirements for engineering projects. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 50 条
  • [21] Measurement of the thermal conductivity of fluids using laser spot lock-in thermography
    Bedoya, A.
    Colom, M.
    Mendioroz, A.
    Salazar, A.
    Marin, E.
    MEASUREMENT, 2020, 158 (158)
  • [22] Laser Lock-in Thermography on Dental Inspection
    Yong, Andrew Ngo Chun
    Lu, Ding
    Sivaraja, Vinod Kumar
    45TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 38, 2019, 2102
  • [23] Estimating thermal properties of coatings by using multi-frequency lock-in thermography
    Zito, Rocco
    Ferrarini, Giovanni
    Laureti, Stefano
    Bison, Paolo
    Ricci, Marco
    THERMOSENSE: THERMAL INFRARED APPLICATIONS XLVI, 2024, 13047
  • [24] Parameters in lock-in thermography of CFRP laminates
    Myrach, Philipp
    Maierhofer, Christiane
    Rahammer, Markus
    Kreutzbruck, Marc
    MATERIALS TESTING, 2016, 58 (01) : 31 - 35
  • [25] Lock-in thermography with a focal plane array
    Horny, N
    Lannoy, B
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (04) : 439 - 443
  • [26] Use of lock-in thermography in industrial applications
    Giorleo, Giuseppe
    Meola, Carosena
    Squillace, Antonino
    Nondestructive Testing and Evaluation, 2000, 16 (01) : 15 - 29
  • [27] Lock-in thermography for nondestructive evaluation of materials
    Wu, DT
    Busse, G
    REVUE GENERALE DE THERMIQUE, 1998, 37 (08): : 693 - 703
  • [28] Lock-in thermography for characterization of nuclear materials
    Semerok, Alexandre
    Sang Pham Tu Quoc
    Cheymol, Guy
    Gallou, Catherine
    Maskrot, Hicham
    Moutiers, Gilles
    EPJ NUCLEAR SCIENCES & TECHNOLOGIES, 2016, 2
  • [29] Local efficiency analysis of solar cells based on lock-in thermography
    Breitenstein, Otwin
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2012, 107 : 381 - 389
  • [30] Comparison of Pulsed and Lock-In Thermography Techniques for Debond Detection in Ni-B Coatings
    Sharath, D.
    Menaka, M.
    Venkatraman, B.
    MATERIALS EVALUATION, 2019, 77 (12) : 1450 - 1462