A new measurement method of coatings thickness based on lock-in thermography

被引:31
|
作者
Zhang, Jin-Yu [1 ]
Meng, Xiang-bin [1 ]
Ma, Yong-chao [1 ]
机构
[1] Xian Res Inst Hightech, 2 Tongxin Rd, Xian 710025, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Functional coatings; Coatings thickness measurement; Lock-in thermography; Infrared thermal wave non-destructive testing; INSPECTION;
D O I
10.1016/j.infrared.2016.04.028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Coatings have been widely used in modern industry and it plays an important role. Coatings thickness is directly related to the performance of the functional coatings, therefore, rapid and accurate coatings thickness inspection has great significance. Existing coatings thickness measurement method is difficult to achieve fast and accurate on-site non-destructive coatings inspection due to cost, accuracy, destruction during inspection and other reasons. This paper starts from the introduction of the principle of lock-in thermography, and then performs an in-depth study on the application of lock-in thermography in coatings inspection through numerical modeling and analysis. The numerical analysis helps explore the relationship between coatings thickness and phase, and the relationship lays the foundation for accurate calculation of coatings thickness. The author sets up a lock-in thermography inspection system and uses thermal barrier coatings specimens to conduct an experiment. The specimen coatings thickness is measured and calibrated to verify the quantitative inspection. Experiment results show that the lock-in thermography method can perform fast coatings inspection and the inspection accuracy is about 95%. Therefore, the method can meet the field testing requirements for engineering projects. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 50 条
  • [11] Measurement of defect thickness of the wall thinning defect pipes by lock-in infrared thermography technique
    Kim, Kyeongsuk
    Kim, Kyungsu
    Jung, Hyunchul
    Chang, Hosub
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522
  • [12] Multiplexed lock-in thermography
    Kopera, Bernd A. F.
    Retsch, Markus
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (01):
  • [13] Direct measurement of electrocaloric effect based on multi-harmonic lock-in thermography
    Iguchi, Ryo
    Fukuda, Daisuke
    Kano, Jun
    Teranishi, Takashi
    Uchida, Ken-ichi
    APPLIED PHYSICS LETTERS, 2023, 122 (08)
  • [14] GLUED STRUCTURES INSPECTION BASED ON LOCK-IN THERMOGRAPHY
    Perez, Laetitia
    Autrique, Laurent
    TWELFTH INTERNATIONAL CONFERENCE ON QUALITY CONTROL BY ARTIFICIAL VISION, 2015, 9534
  • [15] High-throughput direct measurement of magnetocaloric effect based on lock-in thermography technique
    Hirayama, Yusuke
    Iguchi, Ryo
    Miao, Xue-Fei
    Hono, Kazuhiro
    Uchida, Ken-ichi
    APPLIED PHYSICS LETTERS, 2017, 111 (16)
  • [16] Defect detectability based on square wave lock-in thermography
    Zhu, Pengfei
    Wu, Dan
    Wang, Yifan
    Miao, Zhifei
    APPLIED OPTICS, 2022, 61 (21) : 6134 - 6143
  • [17] Simple Lock-In Technique for Thickness Measurement of Metallic Plates
    Pinotti, Ermanno
    Puppin, Ezio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (02) : 479 - 484
  • [18] Measurement of local thermal contact resistance with a periodic heating method using microscale lock-in thermography
    Ishizaki, Takuya
    Igami, Taichi
    Nagano, Hosei
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (06):
  • [19] Applicability and practical concerns of lock-in thermography for measurement of heat transfer coefficients
    Shi, Zhongyuan
    Dong, Tao
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 126
  • [20] FAST ILLUMINATED LOCK-IN THERMOGRAPHY: AN INLINE SHUNT DETECTION MEASUREMENT TOOL
    Seren, S.
    Hahn, G.
    Demberger, C.
    Nagel, H.
    PVSC: 2008 33RD IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE, VOLS 1-4, 2008, : 1360 - +