Experimental evaluation on thermal performance of an air-cooled absorption refrigeration cycle with NH3-LiNO3 and NH3-NaSCN refrigerant solutions

被引:58
|
作者
Cai, Dehua [1 ]
Jiang, Jingkai [1 ]
He, Guogeng [1 ]
Li, Keqiao [1 ]
Niu, Lijuan [1 ]
Xiao, Ruxi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Absorption refrigeration; Air cooled; Single effect; Ammonia-sodium thiocyanate; Ammonia-lithium nitrate; Experimental results; AMMONIA/LITHIUM NITRATE; CONCENTRATED SOLUTIONS; COOLING SYSTEM; LIQUID AMMONIA; DRIVEN; TECHNOLOGIES; SOLUBILITY; CHILLERS; MIXTURE; HEAT;
D O I
10.1016/j.enconman.2016.04.089
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper experimentally analyzes thermal performance of an air-cooled type single effect absorption refrigeration cycle with ammonia-lithium nitrate and ammonia-sodium thiocyanate solutions as working pairs. Ammonia/salt system has simple construction, low evaporating temperature (<0 degrees C) and high working efficiency. Ammonia is one kind of environment-friendly refrigerants. Hence, ammonia/salt absorption refrigeration cycles are considered to be the most possible ones for practical application in small capacity refrigeration units. An experimental apparatus has been designed and built in Wuhan, China, to evaluate the cycle thermal performance of air-cooled type single effect ammonia/salts absorption refrigeration system. The experimental apparatus operates steadily under different working conditions. A set of tests have been conducted and the corresponding experimental data are measured and recorded to show the variation of the system performances with different system working parameters. For the NH3-LiNO3 system, the measured lowest evaporation temperature reaches -13.1 degrees C with corresponding average system COP of 0.15, and the average refrigerating capacity is about 670 W. For the NH3-NaSCN system, with a measured evaporation temperature of -7.5 degrees C, the corresponding average COP is 0.20, and the average refrigerating capacity was about 590 W. According to the experimental results, the actual measured COP of NH3-NaSCN system are in the range of 0.20-0.35, which are a little higher than that of NH3-LiNO3 system (actual measured COP ranging from 0.15 to 0.29). Under similar working condition, NH3-LiNO3 system can reach a lower evaporation temperature than that of NH3-NaSCN system. The experimental results of the present study demonstrate the feasibility and capability of ammonia/salt absorption refrigeration cycle for freezing purpose under air cooling conditions. Although the coefficient of performance of the experimental apparatus is below expectation while comparing with the theoretical results, optimization methods are put forward by the present paper for further research. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:32 / 43
页数:12
相关论文
共 50 条
  • [41] Convective Heat Transfer Characteristics of Plate Heat Exchanger Used as Solution Cooler in LiNO3-NH3 Diffusion Absorption Refrigeration System
    Wang, Handong
    PROCEEDINGS OF ISHTEC2012, 4TH INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER AND ENERGY CONSERVATION, 2011, : 106 - 110
  • [42] Comparison of the performance of single-effect, half-effect, double-effect in series and inverse and triple-effect absorption cooling systems operating with the NH3-LiNO3 mixture
    Dominguez-Inzunza, L. A.
    Hernandez-Magallanes, J. A.
    Sandoval-Reyes, M.
    Rivera, W.
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 612 - 620
  • [43] Energetic and exergetic performance of NH3-H2O-based absorption refrigeration cycle: effect of operating factor
    Takalkar, Gorakshnath Dadabhau
    Bhosale, Rahul R.
    Mali, Nilesh A.
    Bhagwat, Sunil S.
    INTERNATIONAL JOURNAL OF EXERGY, 2020, 31 (04) : 352 - 369
  • [44] Experimental study on absorption characteristics of a falling film absorber with micro-scale NH3/LiNO3 liquid film
    Liang, Xiao
    He, Guogeng
    Wang, Jinyu
    Zhou, Sai
    Hao, Zian
    Cai, Dehua
    APPLIED THERMAL ENGINEERING, 2022, 200
  • [45] Thermal performance of an absorption-refrigeration system with [emim]Cu2Cl5/NH3 as working fluid
    Chen, Wei
    Bai, Yang
    ENERGY, 2016, 112 : 332 - 341
  • [46] THERMODYNAMIC STUDY OF A 2-STAGE VAPOR ABSORPTION REFRIGERATION SYSTEM USING NH3 REFRIGERANT WITH LIQUID SOLID ABSORBENTS
    KAUSHIK, SC
    KUMAR, R
    ENERGY CONVERSION AND MANAGEMENT, 1985, 25 (04) : 427 - 431
  • [47] Performance of double-effect NH3-H2O absorption cycle
    Department of Power Engineering, Southeast University, Nanjing 210096, China
    Huagong Xuebao, 2007, 4 (829-834):
  • [48] PERFORMANCE OF A LOW-TEMPERATURE NH3-H2O ABSORPTION-REFRIGERATION SYSTEM
    ROGDAKIS, ED
    ANTONOPOULOS, KA
    ENERGY, 1992, 17 (05) : 477 - 484
  • [49] Performance evaluation of NH3/CO2 cascade refrigeration system with ejector subcooling for low-temperature cycle
    Chi, Weikai
    Yang, Qichao
    Chen, Xiaonan
    Liu, Guangbin
    Zhao, Yuanyang
    Li, Liansheng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 136 : 162 - 171
  • [50] A COMPARATIVE-STUDY OF AN ABSORBER HEAT-RECOVERY CYCLE FOR SOLAR REFRIGERATION USING NH3-REFRIGERANT WITH LIQUID SOLID ABSORBENTS
    KAUSHIK, SC
    KUMAR, R
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1987, 11 (01) : 123 - 132