Experimental evaluation on thermal performance of an air-cooled absorption refrigeration cycle with NH3-LiNO3 and NH3-NaSCN refrigerant solutions

被引:58
|
作者
Cai, Dehua [1 ]
Jiang, Jingkai [1 ]
He, Guogeng [1 ]
Li, Keqiao [1 ]
Niu, Lijuan [1 ]
Xiao, Ruxi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Absorption refrigeration; Air cooled; Single effect; Ammonia-sodium thiocyanate; Ammonia-lithium nitrate; Experimental results; AMMONIA/LITHIUM NITRATE; CONCENTRATED SOLUTIONS; COOLING SYSTEM; LIQUID AMMONIA; DRIVEN; TECHNOLOGIES; SOLUBILITY; CHILLERS; MIXTURE; HEAT;
D O I
10.1016/j.enconman.2016.04.089
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper experimentally analyzes thermal performance of an air-cooled type single effect absorption refrigeration cycle with ammonia-lithium nitrate and ammonia-sodium thiocyanate solutions as working pairs. Ammonia/salt system has simple construction, low evaporating temperature (<0 degrees C) and high working efficiency. Ammonia is one kind of environment-friendly refrigerants. Hence, ammonia/salt absorption refrigeration cycles are considered to be the most possible ones for practical application in small capacity refrigeration units. An experimental apparatus has been designed and built in Wuhan, China, to evaluate the cycle thermal performance of air-cooled type single effect ammonia/salts absorption refrigeration system. The experimental apparatus operates steadily under different working conditions. A set of tests have been conducted and the corresponding experimental data are measured and recorded to show the variation of the system performances with different system working parameters. For the NH3-LiNO3 system, the measured lowest evaporation temperature reaches -13.1 degrees C with corresponding average system COP of 0.15, and the average refrigerating capacity is about 670 W. For the NH3-NaSCN system, with a measured evaporation temperature of -7.5 degrees C, the corresponding average COP is 0.20, and the average refrigerating capacity was about 590 W. According to the experimental results, the actual measured COP of NH3-NaSCN system are in the range of 0.20-0.35, which are a little higher than that of NH3-LiNO3 system (actual measured COP ranging from 0.15 to 0.29). Under similar working condition, NH3-LiNO3 system can reach a lower evaporation temperature than that of NH3-NaSCN system. The experimental results of the present study demonstrate the feasibility and capability of ammonia/salt absorption refrigeration cycle for freezing purpose under air cooling conditions. Although the coefficient of performance of the experimental apparatus is below expectation while comparing with the theoretical results, optimization methods are put forward by the present paper for further research. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:32 / 43
页数:12
相关论文
共 50 条
  • [31] Comparison of the experimental evaluation of a solar intermittent refrigeration system for ice production operating with the mixtures NH3/LiNO3 and NH3/LiNO3/H2O
    Moreno-Quintanar, G.
    Rivera, W.
    Best, R.
    RENEWABLE ENERGY, 2012, 38 (01) : 62 - 68
  • [32] Exergoeconomic assessment of two novel absorption-ejection heat pumps for the purposes of supermarkets simultaneous heating and refrigeration using NaSCN/NH3, LiNO3/NH3 and H2O/NH3 as working pairs
    Salehi, S.
    Yari, M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 101 : 178 - 195
  • [33] Experimental studies on air-cooled NH3-H2O based modified gax absorption cooling system
    Jawahar, C. P.
    Saravanan, R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (03): : 658 - 666
  • [34] Experimental studies on an air-cooled two-stage NH3-H2O solar absorption air-conditioning prototype
    Du, S.
    Wang, R. Z.
    Lin, P.
    Xu, Z. Z.
    Pan, Q. W.
    Xu, S. C.
    ENERGY, 2012, 45 (01) : 581 - 587
  • [35] Dynamic Performance Investigation of Single-Effect NH3 + LiNO3 and NH3 + NaSCN Solar Cooling Cycles: A Case Study for Western Indian Climate
    Modi, Nishant
    Pandya, Bhargav
    Kumar, Vinay
    Patel, Jatin
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (05):
  • [36] Performance evaluation of solar absorption-compression cascade refrigeration system with an integrated air-cooled compression cycle
    He, Hui
    Wang, Lin
    Yuan, Junfei
    Wang, Zhanwei
    Fu, Wenxuan
    Liang, Kunfeng
    ENERGY CONVERSION AND MANAGEMENT, 2019, 201
  • [37] Performance of air-cooled absorption air-conditioning systems working with water-(LiBr plus LiI+LiNO3+LiCl)
    Bourouis, M
    Vallès, M
    Medrano, M
    Coronas, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2005, 219 (E2) : 205 - 213
  • [38] Flow boiling heat transfer characteristic of NH3/LiNO3+H2O absorption refrigeration working fluid in horizontal tubes: A comprehensive experimental evaluation and comparison
    Zhou, Sai
    He, Guogeng
    Sun, Wei
    Fan, Mingjing
    Wang, Dechang
    Song, Qinglu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2025, 245
  • [39] PERFORMANCE TEST OF ABSORPTION AIR-COOLING UNIT USING NH4Br-NH3 AND NH4I-NH3 SYSTEMS.
    Yamamoto, Hideki
    Sanga, Seiji
    Tokunaga, Junji
    Industrial and Engineering Chemistry Research, 1987, 26 (11): : 2389 - 2393
  • [40] PERFORMANCE-TEST OF ABSORPTION AIR-COOLING UNIT USING NH4BR-NH3 AND NH4I-NH3 SYSTEMS
    YAMAMOTO, H
    SANGA, S
    TOKUNAGA, J
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1987, 26 (11) : 2389 - 2393