Reconstruction of attenuation map using discrete consistency conditions

被引:62
|
作者
Bronnikov, AV [1 ]
机构
[1] KEMA, NL-6800 ET Arnhem, Netherlands
关键词
attenuation correction; positron emission tomography (PET); single-photon emission computed tomography; (SPECT);
D O I
10.1109/42.870255
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Methods of quantitative emission computed tomography require compensation for linear photon attenuation. A current trend in single-photon emission computed tomography (SPECT) and positron emission tomography (PET) is to employ transmission scanning to reconstruct the attenuation map. Such an approach, however, considerably complicates both the scanner design and the data acquisition protocol. A dramatic simplification could be made if the attenuation map could be obtained directly from the emission projections, without the use of a transmission scan. This can be done by applying the consistency conditions that enable us to identify the operator of the problem and, thus, to reconstruct the attenuation map. In this paper, we propose a new approach based on the discrete consistency conditions. One of the main advantages of the suggested method over previously used continuous conditions is that it can easily be applied in various scanning configurations, including fully three-dimensional (3-D) data acquisition protocols. Also, it provides a stable numerical implementation, allowing us to avoid the crosstalk between the attenuation map and the source function. A computationally efficient algorithm is implemented by using the QR and Cholesky decompositions. Application of the algorithm to computer-generated and experimentally measured SPECT data is considered.
引用
收藏
页码:451 / 462
页数:12
相关论文
共 50 条
  • [21] Attenuation correction for dedicated breast PET using only emission data based on consistency conditions
    王璐
    柴培
    武丽伟
    贠明凯
    周小林
    刘双全
    张玉包
    单保慈
    魏龙
    [J]. Chinese Physics C, 2013, (01) : 138 - 143
  • [22] Attenuation correction for dedicated breast PET using only emission data based on consistency conditions
    王璐
    柴培
    武丽伟
    贠明凯
    周小林
    刘双全
    张玉包
    单保慈
    魏龙
    [J]. Chinese Physics C., 2013, 37 (01) - 143
  • [23] SPECT attenuation correction based on combined transmission-emission reconstruction of the attenuation map
    Bronnikov, AV
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3484 - 3486
  • [24] Attenuation correction in PET using consistency information
    Welch, A
    Campbell, C
    Clackdoyle, R
    Natterer, F
    Hudson, M
    Bromiley, A
    Mikecz, P
    Chillcot, F
    Dodd, M
    Hopwood, P
    Craib, S
    Gullberg, GT
    Sharp, P
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3134 - 3141
  • [25] CONDITIONS OF SIGNAL RECONSTRUCTION BY DISCRETE VALUES
    KLOSOV, OI
    [J]. DOPOVIDI AKADEMII NAUK UKRAINSKOI RSR SERIYA A-FIZIKO-MATEMATICHNI TA TECHNICHNI NAUKI, 1983, (11): : 15 - 16
  • [26] Attenuation map segmentation without reconstruction using a level set method in nuclear medicine imaging
    Debreuve, E
    Barlaud, M
    Aubert, G
    Darcourt, J
    [J]. 1998 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING - PROCEEDINGS, VOL 1, 1998, : 34 - 38
  • [27] Attenuation map reconstruction from emission and transmission SPECT data
    Erlandsson, K
    Waddington, WA
    Cullum, ID
    Davies, G
    Pilowsky, LS
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1251 - 1254
  • [28] Spline approximation application to reconstruction of discrete map functions
    Tomashevskaya, Maria
    [J]. INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 2007, 17 (10): : 3663 - 3667
  • [29] Ekg-less cardiac reconstruction using Helgason-Ludwig consistency conditions
    Cesmeli, E
    Hsieh, J
    Edic, PM
    Iatrou, M
    Pfoh, AH
    Gupta, R
    [J]. RADIOLOGY, 2002, 225 : 309 - 309
  • [30] Consistency conditions and linear reconstruction methods in diffraction tomography
    Pan, XC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (01) : 51 - 54