Detective quantum efficiency [DQE(0)] of CZT semiconductor detectors for digital radiography

被引:1
|
作者
Giakos, GC [1 ]
Suryanarayanan, S
Guntupalli, R
Odogba, J
Shah, N
Vedantham, S
Chowdhury, S
Mehta, K
Sumrain, S
Patnekar, N
Moholkar, A
Kumar, V
Endorf, RE
机构
[1] Univ Akron, Dept Elect & Comp Engn, Imaging Syst Detectors & Sensors Lab, Akron, OH 44325 USA
[2] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
[3] Univ Akron, Div Engn & Appl Math, Akron, OH 44325 USA
[4] Univ Cincinnati, Dept Phys, Cincinnati, OH 45221 USA
关键词
detective quantum efficiency; digital radiography; semiconductor detectors;
D O I
10.1109/TIM.2004.834590
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the detective quantum efficiency (DQE) of cadmium zinc telluride (CZT) detector samples for digital radiography has been measured. Specifically, this study is aimed at investigating the zero-frequency DQE(0) under different X-ray tube and detector parameters. The experimental results of this study indicate that the DQE(0) of the CZT samples is strongly dependent upon the irradiation geometry. This is attributed to the incomplete charge collection process, which can be further improved by controlling the purity of the samples and the contact type.
引用
收藏
页码:1479 / 1484
页数:6
相关论文
共 50 条
  • [21] Assessment of objective image quality in digital radiography - Non-invasive determination of the Detective Quantum Efficiency
    Kamm, KF
    Steiner, R
    Tilkorn, K
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 194 - 205
  • [22] An experimental method for the determination of spatial-frequency-dependent detective quantum efficiency (DQE) of scintillators used in X-ray imaging detectors
    Kandarakis, I
    Cavouras, D
    Panayiotakis, GS
    Triantis, D
    Nomicos, CD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3): : 335 - 342
  • [23] Application of DQE for quantitative assessment of detectors to estimate AEC efficiency in digital mammography
    Fabiszewska, Ewa
    Wysocka-Rabin, Anna
    Dobrzynska, Magdalena
    Skrzynski, Witold
    Pasicz, Katarzyna
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (01): : 51 - 56
  • [24] DETECTIVE QUANTUM EFFICIENCY FOR NON-LINEAR DETECTORS OF RADIATION
    TEREBIZH, VY
    ASTRONOMICHESKII ZHURNAL, 1981, 58 (01): : 221 - 222
  • [25] Detective quantum efficiency of television X-ray detectors
    Kalata, Kenneth
    Stanton, Martin
    Phillips, Walter
    Journal of X-Ray Science and Technology, 1992, 3 (03)
  • [26] Measurement of the Detective Quantum Efficiency (DQE) of digital X-ray imaging devices according to the standard IEC 62220-1
    Illers, H
    Buhr, E
    Bergmann, D
    Hoeschen, C
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 177 - 187
  • [27] Detective quantum efficiency of electron area detectors in electron microscopy
    McMullan, G.
    Chen, S.
    Henderson, R.
    Faruqi, A. R.
    ULTRAMICROSCOPY, 2009, 109 (09) : 1126 - 1143
  • [28] Optimization using detective quantum efficiency (DQE) of the high-resolution parallel-hole collimators with CdTe pixelated semiconductor SPECT system
    Lee, Young-Jin
    Kim, Dae-Hong
    Kim, Ye-seul
    Kim, Hee-Joung
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [29] Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography
    Patrik Sund
    Magnus Båth
    Susanne Kheddache
    Lars Gunnar Månsson
    European Radiology, 2004, 14 : 48 - 58
  • [30] Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography
    Sund, P
    Båth, M
    Kheddache, S
    Månsson, LG
    EUROPEAN RADIOLOGY, 2004, 14 (01) : 48 - 58