Enhanced enantioseparation performance in cyclodextrin-electrokinetic chromatography using quinine modified polydopamine coated capillary column

被引:4
|
作者
Yi, Gaoyi [1 ]
Ji, Baian [1 ]
Du, Jianjun [1 ]
Zhou, Jiahao [1 ]
Chen, Zhiyi [1 ]
Mao, Yang [1 ]
Wei, Yiwen [1 ]
Xia, Zhining [2 ]
Fu, Qifeng [1 ]
机构
[1] Southwest Med Univ, Sch Pharm, Luzhou 646000, Peoples R China
[2] Chongqing Univ, Sch Pharmaceut Sci, Chongqing 401331, Peoples R China
关键词
Electrokinetic chromatography; Enantioseparation; Cyclodextrin; Quinine; Polydopamine; STATIONARY-PHASE; ENANTIOMERIC SEPARATION; LIQUID-CHROMATOGRAPHY; CHIRAL SELECTORS; ELECTROCHROMATOGRAPHY; ELECTROPHORESIS; DERIVATIVES; CHEMISTRY; FACILE; DRUGS;
D O I
10.1016/j.microc.2021.106315
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Exploring the innovative strategies for improving the enantioseparation performance of CDs-based electrokinetic chromatography (CD-EKC) has great significance for chiral separation. In this study, a novel quinine (QUI) modified polydopamine (PDA) coated capillary (QUI/PDA@capillary) was firstly fabricated via the chiral alkaloid-inducing co-deposition strategy and applied for enhancing the enantioseparation performance of CDEKC using QUI as the immobilized auxiliary modifiers. With the assistance of solvothermal process, the onepot co-deposition process of QUI/PDA coating was rapidly completed within 60 min, significantly improving the preparation efficiency and simplifying the coating procedure. The successful preparation of the QUI/PDA coated capillary was confirmed by several measurements. Compared with the unmodified, PDA coated and PDA/ branched polyethyleneimine (PEI) co-deposited capillaries, significantly improved enantioseparation performances of eight chiral analytes were observed using QUI/PDA@capillary and baseline separation with high efficiency was all easily obtained. The possible mechanism of the remarkably enhanced enantioseparation obtained using QUI/PDA@capillary was also investigated. The relative standard deviations (RSDs) of the enantiomers' retention times for intra-day, inter-day and column-to-column were all less than 5%. Moreover, the fabricated QUI/PDA coated capillary possessed good stability and long lifetime. These results show the promising prospects of PDA-assisted modification strategy for enhancing the enantioseparation performance and applicability of CD-EKC.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Chiral separation of vinpocetine using cyclodextrin-modified micellar electrokinetic chromatography
    Ibrahim, Wan Aini Wan
    Abd Wahib, Siti Munirah
    Hermawan, Dadan
    Sanagi, Mohd Marsin
    Aboul-Enein, Hassan Y.
    [J]. CHIRALITY, 2012, 24 (03) : 252 - 254
  • [32] Preparation of cyclodextrin-modified monolithic hybrid columns for the fast enantioseparation of hydroxy acids in capillary liquid chromatography
    Szwed, Kamila
    Ou, Junjie
    Huang, Guang
    Lin, Hui
    Liu, Zhongshan
    Wang, Hongwei
    Zou, Hanfa
    [J]. JOURNAL OF SEPARATION SCIENCE, 2016, 39 (06) : 1110 - 1117
  • [33] Chiral separation of sertraline with microemulsion electrokinetic chromatography on a polymer/β-cyclodextrin assembling molecular film modified capillary
    Cheng, Hongying
    He, Baoku
    Zhang, Qianli
    Tu, Yifeng
    [J]. Analytical Sciences, 2010, 26 (10): : 1087 - 1092
  • [34] Chiral Separation of Sertraline with Microemulsion Electrokinetic Chromatography on a Polymer/β-cyclodextrin Assembling Molecular Film Modified Capillary
    Cheng, Hongying
    He, Baoku
    Zhang, Qianli
    Tu, Yifeng
    [J]. ANALYTICAL SCIENCES, 2010, 26 (10) : 1087 - 1092
  • [35] Validation and further optimisation of a cyclodextrin-modified micellar electrokinetic capillary chromatography method for urine profiling
    Guillo, C
    Perrett, D
    Hanna-Brown, M
    [J]. CHROMATOGRAPHIA, 2004, 59 (Suppl 2) : S157 - S164
  • [36] Validation and Further Optimisation of a Cyclodextrin-Modified Micellar Electrokinetic Capillary Chromatography Method for Urine Profiling
    Ch. Guillo
    D. Perrett
    M. Hanna-Brown
    [J]. Chromatographia, 2004, 59 : S157 - S164
  • [37] Chiral Separation of Sertraline with Microemulsion Electrokinetic Chromatography on a Polymer/β-cyclodextrin Assembling Molecular Film Modified Capillary
    Hongying Cheng
    Baoku He
    Qianli Zhang
    Yifeng Tu
    [J]. Analytical Sciences, 2010, 26 : 1087 - 1092
  • [38] Separation of hydrohalocarbons and chlorofluorocarbons using a cyclodextrin gas solid chromatography capillary column
    O'Doherty, SJ
    Nickless, G
    Bassford, M
    Pajot, M
    Simmonds, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) : 253 - 258