Fast and Unbiased 3D Calibration Method of Arbitrary Scintillator Based PET Detectors

被引:0
|
作者
Schug, David [1 ]
Kiessling, Fabian [2 ]
Schulz, Volkmar [1 ,3 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, Aachen, Germany
[2] Univ Aachen, RWTH, Instr Exper Molecular Img, Aachen, Germany
[3] Philips Res, Dept Mol Img Syst, Aachen, Germany
关键词
PET; DOI; monolithic scintillators; QUASI-MONOLITHIC DETECTOR; DOI CAPABILITY; DEPTH;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In high resolution positron emission tomography (PET) more and more scintillator crystal geometries other than pixelated arrays are being investigated. For pixelated crystal arrays an intrinsic spatial calibration can be used as the crystal bins are separable in a center-of-gravity 2D flood histogram. Monolithic crystals, on the other hand, can not be calibrated without a collimated beam or using a model for the light distribution describing the scintillation position. In this paper we present a method which allows to gather calibration data in a PET crystal without the need for a model of the light distribution. The method uses reference calibration beams from different directions which are electronically collimated. To obtain reference calibration lines we combine a high resolution Na-22 point source with a diameter of 0.25 mm and electronically collimate it using a high resolution preclinical LYSO crystal array with a pitch of 1 mm using a light guide for light sharing between crystals. Interactions of the gammas are known to lie on this calibration line. We use at least two intersecting calibration lines and identify the coincident singles at the point of geometrical intersection. These events are then used as calibration data at the intersection point in the crystal. The method operates on the channel space defined by the 64 readout channels of the digital silicon photomultiplier (dSiPM) PDPC DLS 3200-22 sensor. We use the eucledian distance in the channel space to compare two singles. A k-nearest neighbors (k-NN) algorithm is employed to identify the events which define to the point-of-intersection of two calibration lines. This corresponds to finding the point in channel space with the highest value for the multiplied single density. We show, as a proof of concept, that we can calibrate a traditional preclinical crystal array without the use of a clustering algorithm operating on a center-of-gravity position histogram.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] 3D in-system calibration method for PET detectors
    Kuhl, Yannick
    Mueller, Florian
    Thull, Julian
    Naunheim, Stephan
    Schug, David
    Schulz, Volkmar
    MEDICAL PHYSICS, 2024,
  • [2] 3D printing of inorganic scintillator-based particle detectors
    Sibilieva, T.
    Alekseev, V.
    Barsuk, S.
    Berns, S.
    Boillat, E.
    Boiaryntseya, I
    Boyarintsev, A.
    Carbone, A.
    De Roeck, A.
    Dolan, S.
    Driuk, T.
    Gendotti, A.
    Gerasymov, I.
    Grynyov, B.
    Hugon, S.
    Kose, U.
    Opolonin, O.
    Rubbia, A.
    Sgalaberna, D.
    Sibilyev, M.
    Tretyak, S.
    Weber, T.
    Wuthrich, J.
    Zhao, X. Y.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (03)
  • [3] A Fast Calibration Method for 3D Printing Robot Based on Distance Constraint
    Ma, Kaiwei
    Zhao, Tianzheng
    Li, Lan
    Adewale, Orelaja Oluseyi
    Xia, Dan
    Wang, Xingsong
    2019 7TH INTERNATIONAL CONFERENCE ON ROBOT INTELLIGENCE TECHNOLOGY AND APPLICATIONS (RITA), 2019, : 106 - 111
  • [4] Influence of sensor arrangements and scintillator crystal properties on the 3D precision of monolithic scintillation detectors in PET
    Ojala, Peter
    Bousselham, Abdelkader
    Eriksson, Lars
    Brahme, Anders
    Bohm, Christian
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 3018 - 3021
  • [5] A method for precise absolute calibration of scintillator/photodiode detectors
    Avdeichikov, VV
    Jakobsson, B
    van Veldhuizen, EJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3): : 522 - 525
  • [6] Energy calibration using scintillator background radiation for high -resolution PET detectors
    Wang, Liwei
    Wang, Yonggang
    Wang, Mingchen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 974
  • [7] Joint calibration method of camera and lidar based on 3D calibration plate
    Wang Q.
    Tan R.
    Feng Y.
    Yan C.
    Sun Y.
    Zhongguo Guanxing Jishu Xuebao/Journal of Chinese Inertial Technology, 2023, 31 (01): : 100 - 106
  • [8] 3D Simulation and Modeling of Ultra-fast 3D Silicon Detectors
    Liu, Manwen
    Li, Zheng
    Feng, Mingfu
    2017 INTERNATIONAL CONFERENCE ON MECHANICAL, AERONAUTICAL AND AUTOMOTIVE ENGINEERING (ICMAA 2017), 2017, 108
  • [9] Fast 3D kernel computation method for positron range correction in PET
    Li, Chong
    Scheins, Juergen
    Tellmann, Lutz
    Issa, Ahlam
    Wei, Long
    Shah, N. Jon
    Lerche, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (02):
  • [10] Design and calibration of a fast 3D scanning LADAR
    Xiang, Zhiyu
    Wu, Eryong
    IEEE ICMA 2006: PROCEEDING OF THE 2006 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-3, PROCEEDINGS, 2006, : 211 - +