Fast 3D kernel computation method for positron range correction in PET

被引:1
|
作者
Li, Chong [1 ,2 ]
Scheins, Juergen [1 ]
Tellmann, Lutz [1 ]
Issa, Ahlam [1 ,4 ,5 ]
Wei, Long [2 ]
Shah, N. Jon [1 ,3 ,4 ,5 ]
Lerche, Christoph [1 ]
机构
[1] Forschungszentrum Julich GmbH, Inst Neurosci & Med, INM 4, Julich, Germany
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China
[3] Forschungszentrum Julich GmbH, Inst Neurosci & Med, INM 11, Julich, Germany
[4] Rhein Westfal TH Aachen, Dept Neurol, Aachen, Germany
[5] Rhein Westfal TH Aachen, JARA BRAIN Translat Med, Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 02期
关键词
PET; spatial resolution; positron range; range correction; IMAGE-RECONSTRUCTION; RESOLUTION; MODEL;
D O I
10.1088/1361-6560/acaa84
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The positron range is a fundamental, detector-independent physical limitation to spatial resolution in positron emission tomography (PET) as it causes a significant blurring of underlying activity distribution in the reconstructed images. A major challenge for positron range correction methods is to provide accurate range kernels that inherently incorporate the generally inhomogeneous stopping power, especially at tissue boundaries. In this work, we propose a novel approach to generate accurate three-dimensional (3D) blurring kernels both in homogenous and heterogeneous media to improve PET spatial resolution. Approach. In the proposed approach, positron energy deposition was approximately tracked along straight paths, depending on the positron stopping power of the underlying material. The positron stopping power was derived from the attenuation coefficient of 511 keV gamma photons according to the available PET attenuation maps. Thus, the history of energy deposition is taken into account within the range of kernels. Special emphasis was placed on facilitating the very fast computation of the positron annihilation probability in each voxel. Results. Positron path distributions of F-18 in low-density polyurethane were in high agreement with Geant4 simulation at an annihilation probability larger than 10(-2) similar to 10(-3) of the maximum annihilation probability. The Geant4 simulation was further validated with measured F-18 depth profiles in these polyurethane phantoms. The tissue boundary of water with cortical bone and lung was correctly modeled. Residual artifacts from the numerical computations were in the range of 1%. The calculated annihilation probability in voxels shows an overall difference of less than 20% compared to the Geant4 simulation. Significance. The proposed method is expected to significantly improve spatial resolution for non-standard isotopes by providing sufficiently accurate range kernels, even in the case of significant tissue inhomogeneities.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Fast Positron Range Calculation in Heterogeneous Media for 3D PET Reconstruction
    Szirmay-Kalos, Laszlo
    Magdics, Milan
    Toth, Balazs
    Csebfalvi, Balazs
    Umenhoffer, Tamas
    Lantos, Judit
    Patay, Gergely
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2150 - 2155
  • [2] Tissue-Dependent and Spatially-Variant Positron Range Correction in 3D PET
    Cal-Gonzalez, Jacobo
    Perez-Liva, Mailyn
    Herraiz, Joaquin L.
    Vaquero, Juan J.
    Desco, Manuel
    Udias, Jose M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (11) : 2394 - 2403
  • [3] Generalized 3D Kernel Computation Method and Its Application in PET-Insert System
    Pal, Debashish
    O'Sullivan, Joseph A.
    Wu, Heyu
    Tai, Yuan-Chuan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1711 - 1714
  • [4] Study of CT-based positron range correction in high resolution 3D PET imaging
    Cal-Gonzalez, J.
    Herraiz, J. L.
    Espana, S.
    Vicente, E.
    Herranz, E.
    Desco, M.
    Vaquero, J. J.
    Udias, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S172 - S175
  • [5] Positron Range Effects in High Resolution 3D PET Imaging
    Cal-Gonzalez, J.
    Herraiz, J. L.
    Espana, S.
    Desco, M.
    Vaquero, J. J.
    Udias, J. M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2788 - +
  • [6] Evaluation of MAP image reconstruction with positron range modeling for 3D PET
    Bai, Bing
    Laforest, Richard
    Smith, Anne M.
    Leahy, Richard M.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2686 - 2689
  • [7] A Computation Effective Range-Based 3D Mapping Aided GNSS with NLOS Correction Method
    Ng, Hoi-Fung
    Zhang, Guohao
    Hsu, Li-Ta
    JOURNAL OF NAVIGATION, 2020, 73 (06): : 1202 - 1222
  • [8] A method for calibrating 3D PET without scatter correction
    Bailey, DL
    Jones, T
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1046 - 1049
  • [9] PET iterative reconstruction incorporating an efficient positron range correction method
    Bertolli, Ottavia
    Eleftheriou, Afroditi
    Cecchetti, Matteo
    Camarlinghi, Niccol
    Belcari, Nicola
    Tsoumpas, Charalampos
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 323 - 330
  • [10] 3D attenuation correction in PET
    Campbell, C
    Welch, A
    Mikecz, P
    Evans, N
    Chaloner, F
    Chilcott, F
    Sharp, P
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1542 - 1545