Fast and Unbiased 3D Calibration Method of Arbitrary Scintillator Based PET Detectors

被引:0
|
作者
Schug, David [1 ]
Kiessling, Fabian [2 ]
Schulz, Volkmar [1 ,3 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, Aachen, Germany
[2] Univ Aachen, RWTH, Instr Exper Molecular Img, Aachen, Germany
[3] Philips Res, Dept Mol Img Syst, Aachen, Germany
关键词
PET; DOI; monolithic scintillators; QUASI-MONOLITHIC DETECTOR; DOI CAPABILITY; DEPTH;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In high resolution positron emission tomography (PET) more and more scintillator crystal geometries other than pixelated arrays are being investigated. For pixelated crystal arrays an intrinsic spatial calibration can be used as the crystal bins are separable in a center-of-gravity 2D flood histogram. Monolithic crystals, on the other hand, can not be calibrated without a collimated beam or using a model for the light distribution describing the scintillation position. In this paper we present a method which allows to gather calibration data in a PET crystal without the need for a model of the light distribution. The method uses reference calibration beams from different directions which are electronically collimated. To obtain reference calibration lines we combine a high resolution Na-22 point source with a diameter of 0.25 mm and electronically collimate it using a high resolution preclinical LYSO crystal array with a pitch of 1 mm using a light guide for light sharing between crystals. Interactions of the gammas are known to lie on this calibration line. We use at least two intersecting calibration lines and identify the coincident singles at the point of geometrical intersection. These events are then used as calibration data at the intersection point in the crystal. The method operates on the channel space defined by the 64 readout channels of the digital silicon photomultiplier (dSiPM) PDPC DLS 3200-22 sensor. We use the eucledian distance in the channel space to compare two singles. A k-nearest neighbors (k-NN) algorithm is employed to identify the events which define to the point-of-intersection of two calibration lines. This corresponds to finding the point in channel space with the highest value for the multiplied single density. We show, as a proof of concept, that we can calibrate a traditional preclinical crystal array without the use of a clustering algorithm operating on a center-of-gravity position histogram.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] High resolution 3D brain PET with hybrid photon detectors
    Llatas, MC
    Braem, A
    Chesi, E
    Joram, C
    Mathot, S
    Seguinot, J
    Weilhammer, P
    Garibaldi, F
    Nappi, E
    Schoenahl, F
    Zaidi, H
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 391 - 395
  • [32] Investigation of an in situ position calibration method for continuous crystal-based PET detectors
    Bruyndonckx, Peter
    Lemaitre, Cedric
    Schaart, Dennis
    Maas, Marnix
    van der Laan, D. J.
    Krieguer, Magalie
    Devroede, Olivier
    Tavernier, Stefaan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 304 - 307
  • [33] A Fast Dynamic Gesture Recognition Method Based on 3D Trajectory
    He, Wei
    Wang, Yong
    Zhou, Mu
    Xie, Liangbo
    Long, Quan
    Fu, Li
    2022 IEEE 10TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION, APCAP, 2022,
  • [34] Fast method for geometric calibration of detectors and for checking of matching between two detectors
    Petchenova, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (2-3): : 375 - 385
  • [35] An Analytic Calibration Method for Turntable-Based 3D Scanning System
    Zhu, Kai
    Gong, Liang
    Gu, Dajing
    Liu, Chengliang
    2019 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2019, : 495 - 500
  • [36] Self-Calibration Method for a Robotic Based 3D Scanning System
    Wagner, Maximilian
    Hess, Peter
    Reitelshoefer, Sebastian
    Franke, Joerg
    PROCEEDINGS OF 2015 IEEE 20TH CONFERENCE ON EMERGING TECHNOLOGIES & FACTORY AUTOMATION (ETFA), 2015,
  • [37] Portable ultrasonic 3D tag system based on a quick calibration method
    Nishitani, A
    Nishida, Y
    Hori, T
    Mizoguchi, H
    2004 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN & CYBERNETICS, VOLS 1-7, 2004, : 1561 - 1568
  • [38] A Calibration Method of Anamorphic Lens Camera Based on Virtual 3D Target
    Ma, Mengmeng
    Shao, Haiyan
    Zhang, Jinkai
    Wang, Xiaohui
    Li, Guoping
    2019 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2019, : 205 - 210
  • [39] 3-D modeling of scintillator-based X-ray detectors
    Vieira da Rocha, Jose Gerardo
    Lanceros-Mendez, Senentxu
    IEEE SENSORS JOURNAL, 2006, 6 (05) : 1236 - 1242
  • [40] 3D LIDAR-Camera Extrinsic Calibration Using an Arbitrary Trihedron
    Gong, Xiaojin
    Lin, Ying
    Liu, Jilin
    SENSORS, 2013, 13 (02) : 1902 - 1918