A 3D printed phantom to assess MRI geometric distortion

被引:2
|
作者
Ramachandran, Prabhakar [1 ,2 ]
Noble, Christopher [1 ]
Langton, Christian [3 ,4 ]
Perrett, Ben [1 ]
Cox, Joshua [4 ]
Chapman, Mike [4 ]
McGill, George [5 ]
机构
[1] Princess Alexandra Hosp, Dept Radiat Oncol, Woolloongabba, Qld 4102, Australia
[2] Queensland Univ Technol, Sci & Engn Fac, Brisbane, Qld 4000, Australia
[3] Queensland Univ Technol, Fac Hlth, Clin Sci, Kelvin Grove, Qld 4059, Australia
[4] 3D One Australia Pty Ltd, Salisbury, Qld 41076, Australia
[5] Princess Alexandra Hosp, Biomed Tech Serv, Woolloongabba, Qld 4102, Australia
来源
关键词
magnetic resonance imaging; distortion; 3D-printing;
D O I
10.1088/2057-1976/abeb7e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Geometric distortions in magnetic resonance can introduce significant uncertainties into applications such as radiotherapy treatment planning and need to be assessed as part of a comprehensive quality assurance program. We report the design, fabrication, and imaging of a custom 3D printed unibody MR distortion phantom along with quantitative image analysis. Methods: The internal cavity of the phantom is an orthogonal three-dimensional planar lattice, composed of 3 mm diameter rods spaced equidistantly at a 20 mm centre-centre offset repeating along the X, Y, and Z axes. The phantom featured an overall length of 308.5 mm, a width of 246 mm, and a height of 264 mm with lines on the external surface for phantom positioning matched to external lasers. The MR phantom was 3D printed in Nylon-12 using an advancement on traditional selective laser sintering (SLS) (HP Jet Fusion 3D-4200 machine). The phantom was scanned on a Toshiba Aquilion CT scanner to check the integrity of the 3D print and correct for any resultant issues. The phantom was then filled with NiSO4 solution and scanned on a 3T PET-MR Siemens scanner for selected T1 and T2 sequences, from which distortion vectors were generated and analysed using in-house software written in Python. Results: All deviations of the node positions from the print design were less than 1 mm, with an average displacement of 0.228 mm. The majority of the deviations were smaller than the 0.692 mm pixel size for this dataset. Conclusion: A customised 3D printed MRI-phantom was successfully printed and tested for assessing geometric distortion on MRI scanners. 3D printed phantoms can be considered for clinics wishing to assess geometric distortions under specific conditions, but require resources for design, fabrication, commissioning, and verification.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Multiscale Geometric Design Principles Applied to 3D Printed Schwarzites
    Sajadi, Seyed Mohammad
    Owuor, Peter Samora
    Schara, Steven
    Woellner, Cristiano F.
    Rodrigues, Varlei
    Vajtai, Robert
    Lou, Jun
    Galvao, Douglas S.
    Tiwary, Chandra Sekhar
    Ajayan, Pulickel M.
    ADVANCED MATERIALS, 2018, 30 (01)
  • [42] A robotically assisted 3D printed quality assurance lung phantom for Calypso
    Capaldi, Dante P., I
    Skinner, Lawrie B.
    Dubrowski, Piotr
    Zhang, Hao
    Xing, Lei
    Chuang, Cynthia F.
    Loo, Billy W.
    Bush, Karl K.
    Fahimian, Benjamin P.
    Yu, Amy S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [43] Fast and Simple Automatic 3D Ultrasound Probe Calibration Based on 3D Printed Phantom and an Untracked Marker
    Shen, Jun
    Zemiti, Nabil
    Dillenseger, Jean-Louis
    Poignet, Philippe
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 878 - 882
  • [44] Improving Geometric Accuracy of 3D Printed Parts Using 3D Metrology Feedback and Mesh Morphing
    Jadayel, Moustapha
    Khameneifar, Farbod
    JOURNAL OF MANUFACTURING AND MATERIALS PROCESSING, 2020, 4 (04):
  • [45] Development of a 3D Printed Motion Mechanism for a 4D Respiratory Motion Phantom
    Ahmad, Muhammad Akmal
    Mustaza, Seri Mastura
    Mokri, Siti Salasiah
    Azmi, Nor Aniza
    Ahmad, Rozilawati
    Ramli, Rizauddin
    Rahman, Wan Nordiana Wan Abdul
    Abd Rahni, Ashrani Aizzuddin
    2020 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES 2020): LEADING MODERN HEALTHCARE TECHNOLOGY ENHANCING WELLNESS, 2021, : 132 - 135
  • [46] 2D & 3D Shepp-Logan phantom standards for MRI
    Gach, H. Michael
    Tanase, Costin
    Boada, Femando
    ICSENG 2008: INTERNATIONAL CONFERENCE ON SYSTEMS ENGINEERING, 2008, : 521 - +
  • [47] Source identification of 3D printed objects based on inherent equipment distortion
    Peng, Fei
    Yang, Jing
    Lin, Zi-Xing
    Long, Min
    COMPUTERS & SECURITY, 2019, 82 : 173 - 183
  • [48] Design and characterization of a 3D-printed axon-mimetic phantom for diffusion MRI
    Mushtaha, Farah N.
    Kuehn, Tristan K.
    El-Deeb, Omar
    Rohani, Seyed A.
    Helpard, Luke W.
    Moore, John
    Ladak, Hanif
    Moehring, Amanda
    Baron, Corey A.
    Khan, Ali R.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (05) : 2482 - 2496
  • [49] 3D-printed biological cell phantom for testing 3D quantitative phase imaging systems
    Ziemczonok, Michal
    Kus, Arkadiusz
    Wasylczyk, Piotr
    Kujawinska, Malgorzata
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [50] 3D-printed biological cell phantom for testing 3D quantitative phase imaging systems
    Michał Ziemczonok
    Arkadiusz Kuś
    Piotr Wasylczyk
    Małgorzata Kujawińska
    Scientific Reports, 9