A 3D printed phantom to assess MRI geometric distortion

被引:2
|
作者
Ramachandran, Prabhakar [1 ,2 ]
Noble, Christopher [1 ]
Langton, Christian [3 ,4 ]
Perrett, Ben [1 ]
Cox, Joshua [4 ]
Chapman, Mike [4 ]
McGill, George [5 ]
机构
[1] Princess Alexandra Hosp, Dept Radiat Oncol, Woolloongabba, Qld 4102, Australia
[2] Queensland Univ Technol, Sci & Engn Fac, Brisbane, Qld 4000, Australia
[3] Queensland Univ Technol, Fac Hlth, Clin Sci, Kelvin Grove, Qld 4059, Australia
[4] 3D One Australia Pty Ltd, Salisbury, Qld 41076, Australia
[5] Princess Alexandra Hosp, Biomed Tech Serv, Woolloongabba, Qld 4102, Australia
来源
关键词
magnetic resonance imaging; distortion; 3D-printing;
D O I
10.1088/2057-1976/abeb7e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Geometric distortions in magnetic resonance can introduce significant uncertainties into applications such as radiotherapy treatment planning and need to be assessed as part of a comprehensive quality assurance program. We report the design, fabrication, and imaging of a custom 3D printed unibody MR distortion phantom along with quantitative image analysis. Methods: The internal cavity of the phantom is an orthogonal three-dimensional planar lattice, composed of 3 mm diameter rods spaced equidistantly at a 20 mm centre-centre offset repeating along the X, Y, and Z axes. The phantom featured an overall length of 308.5 mm, a width of 246 mm, and a height of 264 mm with lines on the external surface for phantom positioning matched to external lasers. The MR phantom was 3D printed in Nylon-12 using an advancement on traditional selective laser sintering (SLS) (HP Jet Fusion 3D-4200 machine). The phantom was scanned on a Toshiba Aquilion CT scanner to check the integrity of the 3D print and correct for any resultant issues. The phantom was then filled with NiSO4 solution and scanned on a 3T PET-MR Siemens scanner for selected T1 and T2 sequences, from which distortion vectors were generated and analysed using in-house software written in Python. Results: All deviations of the node positions from the print design were less than 1 mm, with an average displacement of 0.228 mm. The majority of the deviations were smaller than the 0.692 mm pixel size for this dataset. Conclusion: A customised 3D printed MRI-phantom was successfully printed and tested for assessing geometric distortion on MRI scanners. 3D printed phantoms can be considered for clinics wishing to assess geometric distortions under specific conditions, but require resources for design, fabrication, commissioning, and verification.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Detection and correction of geometric distortion in 3D MR images
    Breeuwer, M
    Holden, M
    Zylka, W
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1110 - 1120
  • [22] Geometric distortion in mechanically scanned 3D ultrasound images
    Cardinal, H
    Tong, S
    Gill, JD
    Downey, DB
    Fenster, A
    RADIOLOGY, 2000, 217 : 165 - 166
  • [23] A phantom based framework for MR distortion detection and correction in 3D
    Alasti, H.
    Qiu, J.
    Near, J.
    Kirilova, A.
    Affray, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S95 - S95
  • [24] An open source, 3D printed preclinical MRI phantom for repeated measures of contrast agents and reference standards
    Cox, B. L.
    Ludwig, K. D.
    Adamson, E. B.
    Eliceiri, K. W.
    Fain, S. B.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (02):
  • [25] Geometric Evaluation of Biomimetic 3D Printed Rat Femur
    Kim, Dong Hwi
    Byun, Jae Yong
    Kim, Daeok
    Kim, Bosun
    Lim, Wonbong
    JOURNAL OF HARD TISSUE BIOLOGY, 2023, 32 (02) : 133 - 138
  • [26] UWB Antenna on 3D Printed Flexible Substrate and Foot Phantom
    Jun, S.
    Sanz-Izquierdo, B.
    Summerfield, M.
    2015 LOUGHBOROUGH ANTENNAS & PROPAGATION CONFERENCE (LAPC), 2015,
  • [27] 3D printed inhomogeneity phantom for radiotherapy commissioning and QA measurements
    Banjade, D.
    How, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1514 - S1514
  • [28] Patient specific 3D printed phantom for IMRT quality assurance
    Ehler, Eric D.
    Barney, Brett M.
    Higgins, Patrick D.
    Dusenbery, Kathryn E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : 5763 - 5773
  • [29] Design and manufacture of a 3D printed phantom for PET quality control
    Robinson, J.
    Rushforth, D.
    Murray, I.
    Flux, G.
    Gear, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S14 - S14
  • [30] Validation of spine SBRT using a 3D printed Anthropomorphic phantom
    Dekker, K. H.
    Alexander, K. M.
    de Moraes, F. Ynoe
    Olding, T.
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167