Experience with Real-Time Continuous Glucose Monitoring in Newborns with Congenital Hyperinsulinemic Hypoglycemia

被引:1
|
作者
Anik, Ayse [1 ]
Turkmen, Munevver Kaynak [1 ]
Akcan, Abdullah Baris [1 ]
Unuvar, Tolga [2 ]
Ozturk, Sercan [3 ]
Anik, Ahmet [2 ]
机构
[1] Adnan Menderes Univ, Sch Med, Div Neonatol, Pediat, Aydin, Turkey
[2] Adnan Menderes Univ, Sch Med, Div Pediat Endocrinol, Pediat, TR-09100 Aydin, Turkey
[3] Celal Bayar Univ, Sch Med, Pediat, Manisa, Turkey
来源
关键词
morbidity; neonates; neonatology; NEURODEVELOPMENTAL OUTCOMES; NEONATAL GLYCEMIA;
D O I
10.1055/a-1209-3861
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background Effective treatment and close monitoring of hypoglycemia in children with congenital hyperinsulinemic hypoglycemia (CHH) is vital to prevent brain damage. The current use of capillary sampling schedules does not provide a comprehensive assessment of glycemic status and fails to detect asymptomatic hypoglycemia episodes. Aim To investigate the efficacy and accuracy of a real-time continuous glucose monitoring system (RT-CGMS) in neonates with CHH. Methods A sensor connected to RT-CGMS was inserted into the newborn patients and maintained for at least 6 days during their stay in the hospital. We compared the readings of CGMS with capillary blood glucose values using Bland-Altman analysis. Results A total of 110 blood glucose values were compared to readings from the CGMS. All results were calculated and plotted for CGMS values at 0- 4, 5-9, 10-14, 15-19, 20-24, and 25-29 min after capillary blood glucose sampling. CGMS readings were highly correlated with blood glucose values, especially during normoglycemia. In case of hypoglycemia, the mean difference between the CGMS and capillary glucose values was higher. Although the false positive rate for hypoglycemia was relatively high in CGMS, RT-CGMS may show some episodes of hypoglycemia earlier than blood measurement. Conclusion RT-CGMS is accurate during normoglycemia, and it can reduce the number of capillary blood samples in children with CHH.
引用
收藏
页码:155 / 160
页数:6
相关论文
共 50 条
  • [41] Reduced Glycemic Variability with the Use of Real-Time Continuous Glucose Monitoring
    Rodbard, David
    Jovanovic, Lois
    Garg, Satish K.
    Matsubara, Bradley S.
    Nakamura, Katherine
    Bailey, Timothy
    Zisser, Howard
    Kaplan, Roy
    [J]. DIABETES, 2009, 58 : A55 - A55
  • [42] Real-Time Sharing and Following of Continuous Glucose Monitoring Data in Youth
    Welsh, John B.
    Derdzinski, Mark
    Parker, Andrew Scott
    Puhr, Sarah
    Jimenez, Annika
    Walker, Tomas
    [J]. DIABETES THERAPY, 2019, 10 (02) : 751 - 755
  • [43] Real-Time Continuous Glucose Monitoring Systems in the Classroom/School Environment
    Benassi, Kari
    Drobny, Jessica
    Aye, Tandy
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (05) : 409 - 412
  • [44] A Randomized Trial of Real-Time Continuous Glucose Monitoring in Gestational Diabetes
    Ehrhardt, Nicole M.
    Fay, Emily
    Abdalla, Ghada
    Mandava, Patali
    Fonda, Stephanie J.
    [J]. DIABETES, 2024, 73
  • [45] A real-time continuous glucose monitoring for diabetic women during the delivery
    Ghio, A.
    Lencioni, C.
    Romero, F.
    Pancani, F.
    Bertolotto, A.
    Aragona, M.
    Del Prato, S.
    Volpe, L.
    Di Cianni, G.
    [J]. DIABETOLOGIA, 2009, 52 : S462 - S462
  • [46] Continuous Glucose Monitoring in the Management of Neonates With Persistent Hypoglycemia and Congenital Hyperinsulinism
    Win, Myat
    Beckett, Rowan
    Thomson, Lynn
    Thankamony, Ajay
    Beardsall, Kathryn
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2022, 107 (01): : E246 - E253
  • [47] Impact of real-time continuous glucose monitoring on glucose variability in critically ill patients
    R Brunner
    R Kitzberger
    W Miehsler
    V Fuhrmann
    C Madl
    U Holzinger
    [J]. Critical Care, 14 (Suppl 1):
  • [48] Real-Time Continuous Glucose Monitoring Reduces the Duration of Hypoglycemia Episodes: A Randomized Trial in Very Low Birth Weight Neonates
    Uettwiller, Florence
    Chemin, Aude
    Bonnemaison, Elisabeth
    Favrais, Geraldine
    Saliba, Elie
    Labarthe, Francois
    [J]. PLOS ONE, 2015, 10 (01):
  • [49] Glycemic Variability Associated with Time Spent in Hypoglycemia in Type 1 Diabetes-Explorative Data in Real-World, Real-Time Continuous Glucose Monitoring
    Hachmann-Nielsen, Elise
    Bartholdy, Trine
    Djurhuus, Christian Born
    Kvist, Kajsa
    [J]. DIABETES, 2018, 67
  • [50] The Role of Real-Time Glucose Monitoring
    Bernot, John
    Patel, Manali
    Kirk, Julienne K.
    [J]. JOURNAL OF DIABETES & METABOLISM, 2016, 7 (04)