Experience with Real-Time Continuous Glucose Monitoring in Newborns with Congenital Hyperinsulinemic Hypoglycemia

被引:1
|
作者
Anik, Ayse [1 ]
Turkmen, Munevver Kaynak [1 ]
Akcan, Abdullah Baris [1 ]
Unuvar, Tolga [2 ]
Ozturk, Sercan [3 ]
Anik, Ahmet [2 ]
机构
[1] Adnan Menderes Univ, Sch Med, Div Neonatol, Pediat, Aydin, Turkey
[2] Adnan Menderes Univ, Sch Med, Div Pediat Endocrinol, Pediat, TR-09100 Aydin, Turkey
[3] Celal Bayar Univ, Sch Med, Pediat, Manisa, Turkey
来源
关键词
morbidity; neonates; neonatology; NEURODEVELOPMENTAL OUTCOMES; NEONATAL GLYCEMIA;
D O I
10.1055/a-1209-3861
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background Effective treatment and close monitoring of hypoglycemia in children with congenital hyperinsulinemic hypoglycemia (CHH) is vital to prevent brain damage. The current use of capillary sampling schedules does not provide a comprehensive assessment of glycemic status and fails to detect asymptomatic hypoglycemia episodes. Aim To investigate the efficacy and accuracy of a real-time continuous glucose monitoring system (RT-CGMS) in neonates with CHH. Methods A sensor connected to RT-CGMS was inserted into the newborn patients and maintained for at least 6 days during their stay in the hospital. We compared the readings of CGMS with capillary blood glucose values using Bland-Altman analysis. Results A total of 110 blood glucose values were compared to readings from the CGMS. All results were calculated and plotted for CGMS values at 0- 4, 5-9, 10-14, 15-19, 20-24, and 25-29 min after capillary blood glucose sampling. CGMS readings were highly correlated with blood glucose values, especially during normoglycemia. In case of hypoglycemia, the mean difference between the CGMS and capillary glucose values was higher. Although the false positive rate for hypoglycemia was relatively high in CGMS, RT-CGMS may show some episodes of hypoglycemia earlier than blood measurement. Conclusion RT-CGMS is accurate during normoglycemia, and it can reduce the number of capillary blood samples in children with CHH.
引用
收藏
页码:155 / 160
页数:6
相关论文
共 50 条
  • [21] Real-time continuous glucose monitoring decreases the risk of severe hypoglycemia in people with type 1 diabetes and impaired awareness of hypoglycemia
    Lucidi, Paola
    Porcellati, Francesca
    Bolli, Geremia B.
    Fanelli, Carmine G.
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6
  • [22] Switching from Intermittently Scanned Continuous Glucose Monitoring to Real-Time Continuous Glucose Monitoring with a Predictive Urgent Low Soon Alert Reduces Exposure to Hypoglycemia
    Preechasuk, Lukana
    Avari, Parizad
    Oliver, Nick
    Reddy, Monika
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (07) : 498 - 502
  • [23] Improving Epinephrine Responses in Hypoglycemia Unawareness With Real-Time Continuous Glucose Monitoring in Adolescents With Type 1 Diabetes
    Ly, Trang T.
    Hewitt, Jacqueline
    Davey, Raymond J.
    Lim, Ee Mun
    Davis, Elizabeth A.
    Jones, Timothy W.
    [J]. DIABETES CARE, 2011, 34 (01) : 50 - 52
  • [24] A Feasibility Study to Detect Neonatal Hypoglycemia in Infants of Diabetic Mothers Using Real-Time Continuous Glucose Monitoring
    Nally, Laura Marie
    Bondy, Nicholas
    Doiev, Jasmine
    Buckingham, Bruce A.
    Wilson, Darrell M.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (04) : 170 - 176
  • [25] Congenital Hyperinsulinemic Hypoglycemia, our Experience in 34 Patients
    Barreto, T. G.
    Calzada, R.
    Ruiz, M.
    Arguinzoniz, L.
    Altamirano, N.
    Medina, F. A.
    Flanagan, S.
    Aguilar, L.
    Nishimura, E.
    [J]. HORMONE RESEARCH IN PAEDIATRICS, 2019, 92 : 19 - 19
  • [26] New perspectives on real-time continuous glucose monitoring Comment
    Stechova, Katerina
    [J]. LANCET CHILD & ADOLESCENT HEALTH, 2021, 5 (04): : 235 - 236
  • [27] Accuracy of a new real-time continuous glucose monitoring algorithm
    Navas de Solis, M. S.
    [J]. AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 129 - 130
  • [28] Real-time continuous glucose monitoring: proven clinical indiciations
    Gomez Peralta, Fernando
    Abreu Padin, Cristina
    [J]. AVANCES EN DIABETOLOGIA, 2011, 27 (06): : 198 - 203
  • [29] DIABETES Under Control Real-Time Continuous Glucose Monitoring
    Ramchandani, Neesha
    Saadon, Yael
    Jornsay, Donna
    [J]. AMERICAN JOURNAL OF NURSING, 2010, 110 (04) : 60 - 63
  • [30] Is reimbursement for alerts and real-time continuous glucose monitoring needed?
    Norgaard, Kirsten
    Schmidt, Signe
    [J]. LANCET, 2021, 397 (10291): : 2230 - 2232