Measurement and prediction of the indoor airflow in a room ventilated with a commercial wind tower

被引:67
|
作者
Calautit, John Kaiser [1 ]
Hughes, Ben Richard [1 ]
机构
[1] Univ Leeds, Sch Civil Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
Air change effectiveness; Air change rate; CFD; Indoor air quality; Mean age of air; Wind tower/catcher; Wind tunnel; NATURAL VENTILATION; HEAT-TRANSFER; CFD; LOOP; HOT;
D O I
10.1016/j.enbuild.2014.08.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper introduces a method for a full assessment of the internal air movement characteristics in a room ventilated with a commercial wind tower using scaled wind tunnel and computational fluid dynamics (CFD) analysis. An accurate geometrical representation of the experimental situation was recreated in the CFD simulation. The experimental investigation was carried out using a closed-loop low speed wind tunnel and the indoor air flow distribution was measured and compared with the CFD analysis. Good correlation between the numerical and experimental results was observed (10% average error). Flow visualisation was also conducted to further analyse the airflow structure within the room. The work assessed several ventilation parameters to describe the indoor airflow characteristics such as the mean age of air (MAA), air change rate, and air change effectiveness (ACE). The MAA was calculated using the steady-state method, by solving an additional partial differential equation describing the transport of the scalar "age of air". The numerical analysis of the MAA allowed to detect less or insufficiently ventilated areas. The CFD code could be useful for the calculation of the MAA and ACE, allowing reduction in time and cost in the evaluation of indoor air quality in buildings ventilated with wind tower or similar device. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 377
页数:11
相关论文
共 50 条
  • [31] Airflow assessment in a naturally ventilated greenhouse equipped with wind towers: numerical simulation and wind tunnel experiments
    Pakari, Ali
    Ghani, Saud
    ENERGY AND BUILDINGS, 2019, 199 : 1 - 11
  • [32] Effects of temperature and supply airflow rate on thermal comfort in a stratum-ventilated room
    Cheng, Yong
    Lin, Zhang
    Fong, Alan M. L.
    BUILDING AND ENVIRONMENT, 2015, 92 : 269 - 277
  • [33] Numerical simulation of turbulent airflow in a ventilated room: Inlet turbulence parameters and solution multiplicity
    Pulat, Erhan
    Ersan, Hifzi Arda
    ENERGY AND BUILDINGS, 2015, 93 : 227 - 235
  • [34] A numerical study on the relationship between particle dispersion, accumulation, and indoor airflow in different ventilated rooms
    Wang, Wenchao
    Ooka, Ryozo
    Kikumoto, Hideki
    Oh, Wonseok
    Lin, Chao
    Han, Mengtao
    JAPAN ARCHITECTURAL REVIEW, 2023, 6 (01)
  • [35] MEASUREMENT OF THE EFFICIENCY OF IODINE AND IODINE METHYL VAPORS ABSORPTION FROM THE VENTILATED AIRFLOW
    Kolobrodov, V. G.
    Sokolenko, V. I.
    Khazhmuradov, M. A.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2009, (05): : 54 - 56
  • [36] Prediction of airflow and temperature field in a room with convective heat source
    Lu, WZ
    Howarth, AT
    Jeary, AP
    BUILDING AND ENVIRONMENT, 1997, 32 (06) : 541 - 550
  • [37] Measurement of downburst storm wind field and wind response of transmission tower
    Wang, Zhisong
    Xu, Qinglu
    Fang, Zhiyuan
    Yang, Fei
    Zhendong yu Chongji/Journal of Vibration and Shock, 2024, 43 (24): : 267 - 276
  • [38] A Wind Tunnel Study on Influences of ILS Tower on Wind Speed Measurement
    Choi, Cheol-Min
    Kim, Kye-Hwan
    Kim, Young-Chul
    Kwon, Kybeom
    ATMOSPHERE-KOREA, 2013, 23 (04): : 513 - 517
  • [39] Application of artificial neural networks using sequential prediction approach in indoor airflow prediction
    Kim, MinHo
    Park, Hyung-Jun
    JOURNAL OF BUILDING ENGINEERING, 2023, 69
  • [40] Effect of Design Parameters on Indoor Temperature Distribution in Impinging Jet Ventilated Room
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    Yamanaka, Toshio
    Choi, Narae
    Matsuzaki, Mako
    IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,