Dosimetric characterization of a brachytherapy applicator using MCNP5 modelisation and in-phantom measurements

被引:4
|
作者
Gerardy, I. [1 ]
Rodenas, J. [2 ]
van Dycke, M. [3 ]
Gallardo, S. [2 ]
Ceccolini, Elisa [4 ]
机构
[1] Inst Super Ind Bruxelles, B-1000 Brussels, Belgium
[2] Univ Politecn Valencia, Dept Ingn Quim & Nucl, E-46071 Valencia, Spain
[3] Clin St Jean, B-1000 Brussels, Belgium
[4] Alma Mater Studiorum Univ Bologna, Fac Ingn, Bologna, Italy
关键词
Brachytherapy; MCNP5; Dosimetry; Radiochromic films; Pinpoint chamber;
D O I
10.1016/j.apradiso.2009.10.018
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A gynaecological applicator consisting of a metallic intra-uterine tube with a plastic vaginal applicator and an HDR Ir-192 source have been simulated with MCNP5 (Monte Carlo code). A solid phantom has been designed to perform measurements around the applicator with radiochromic films. The isodose curves obtained are compared with curves calculated with the F4MESH tally of MCNP5 with a good agreement. A pinpoint ionization chamber has been used to evaluate dose at some reference points. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:735 / 737
页数:3
相关论文
共 50 条
  • [1] In-phantom dosimetric measurements as quality control for brachytherapy: System check and constancy check
    Kollefrath, Michael
    Bruggmoser, Gregor
    Nanko, Norbert
    Gainey, Mark
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (02): : 176 - 185
  • [2] EchoSeed Model 6733 Iodine-125 brachytherapy source: Improved dosimetric characterization using the MCNP5 Monte Carlo code
    Mosleh-Shirazi, M. A.
    Hadad, K.
    Faghihi, R.
    Baradaran-Ghahfarokhi, M.
    Naghshnezhad, Z.
    Meigooni, A. S.
    MEDICAL PHYSICS, 2012, 39 (08) : 4653 - 4659
  • [3] Uncertainty analysis in MCNP5 calculations for brachytherapy treatment
    Gerardy, I.
    Rodenas, J.
    Gallardo, S.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (08) : 1108 - 1111
  • [4] Monte Carlo study of an electronic brachytherapy source using MCNP5 and EGSnrc
    Davis, S.
    DeWerd, L.
    MEDICAL PHYSICS, 2007, 34 (06) : 2472 - 2473
  • [5] Using MCNP5 to evaluate radiation doses in prostate brachytherapy with cesium-131
    Orabi, M.
    PRAMANA-JOURNAL OF PHYSICS, 2022, 96 (03):
  • [6] Using MCNP5 to evaluate radiation doses in prostate brachytherapy with cesium-131
    M Orabi
    Pramana, 96
  • [7] Dosimetric capabilities of the Iview GT portal imager using MCNP5 Monte Carlo simulations
    Juste, B.
    Miro, R.
    Diez, S.
    Campayo, J. M.
    Verdu, G.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3743 - +
  • [8] An active matrix flat panel dosimeter (AMFPD) for in-phantom dosimetric measurements
    Moran, JM
    Roberts, DA
    Nurushev, TS
    Antonuk, LE
    El-Mohri, Y
    Fraass, BA
    MEDICAL PHYSICS, 2005, 32 (02) : 466 - 472
  • [9] Calculating the Dosimetry Distribution of Leksell Gamma Knife in Phantom Zubal Head by Using MCNP5
    Dang Truong Ka My
    Dang Nguyen Phuong
    Truong Thi Hong Loan
    Mai Van Nhon
    THIRD INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM, 2010, 27 : 106 - +
  • [10] Uncertainty analysis in environmental radioactivity measurements using the Monte Carlo code MCNP5
    Gallardo, S.
    Querol, A.
    Ortiz, J.
    Rodenas, J.
    Verdu, G.
    Villanueva, J. F.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 214 - 218