Optimizing Atrial Electrogram Classification Based on Local Ablation Outcome in Human Atrial Fibrillation

被引:3
|
作者
Bezerra, Arthur S. [1 ]
Yoneyama, Takashi [1 ]
Soriano, Diogo C. [2 ]
Luongo, Giorgio [3 ]
Li, Xin [4 ]
Ravelli, Flavia [5 ]
Mase, Michela [6 ]
Chu, Gavin S. [4 ]
Stafford, Peter J. [4 ]
Schlindwein, Fernando S. [4 ]
Ng, G. Andre [4 ]
de Almeida, Tiago P. [1 ,4 ]
机构
[1] Aeronaut Inst Technol, Praca Marechal Eduardo Gomes 50, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[2] Fed ABC Univ, Santo Andre, SP, Brazil
[3] Karlsruhe Inst Technol, Karlsruhe, Germany
[4] Univ Leicester, Leicester, Leics, England
[5] Univ Trento, Trento, Italy
[6] Eurac Res, Bolzano, Italy
来源
2020 COMPUTING IN CARDIOLOGY | 2020年
基金
巴西圣保罗研究基金会; 英国医学研究理事会;
关键词
CATHETER; LENGTH;
D O I
10.22489/CinC.2020.131
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Changes in atrial fibrillation cycle length (AF-CL) are broadly used as a 'ground truth' to assess the effect of substrate modification during AF ablation. This work sought to optimize thresholds for changes in coronary sinus CL (CS-CL) after local ablation using different atrial electrogram (AEG)-derived markers. 834 AEGs were collected from 11 patients undergoing persAF ablation. CS-CL was measured before and after each ablation point. Five AEG-derived markers were tested as classifiers for CS-CL changes: ICL (Biosense Webster), CFE-Mean (St. Jude Medical), Wave Similarity, Shannon Entropy and AEG-CL. The area under the receiver operating characteristic (AUROC) curve was used to assess the quality of classification for each marker. Maximum AUROC was found at threshold values between 9 and 14 ms in all markers, except for Shannon Entropy. The average AUROC of the five markers reached a maximum of 0.60 at a threshold value of 10 ms. The 10 ms threshold is suggested as a starting setpoint for future studies seeking to identify AF ablation targets based on an objective 'ground truth'.
引用
收藏
页数:4
相关论文
共 50 条
  • [11] Right atrial diameter and outcome of catheter ablation of atrial fibrillation
    Wen, Song-Nan
    Liu, Nian
    Bai, Rong
    Tang, Ri-Bo
    Yu, Rong-Hui
    Long, De-Yong
    Sang, Cai-Hua
    Jiang, Chen-Xi
    Li, Song-Nan
    Wu, Jia-Hui
    Ruan, Yan-Fei
    Hu, Rong
    Du, Xin
    Liu, Xiao-Hui
    Dong, Jian-Zeng
    Ma, Chang-Sheng
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (02) : 157 - 164
  • [12] Frequency-domain versus time-domain analysis: Optimizing complex fractionated atrial electrogram identification for atrial fibrillation ablation
    Nattel, Stanley
    HEART RHYTHM, 2009, 6 (10) : 1483 - 1484
  • [13] Distribution of atrial electrogram types during atrial fibrillation: Effect of rapid atrial pacing and intercaval junction ablation
    Li, HG
    Hare, J
    Mughal, K
    Krum, D
    Biehl, M
    Deshpande, S
    Dhala, A
    Blanck, Z
    Sra, J
    Jazayeri, M
    Akhtar, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (07) : 1713 - 1721
  • [14] Modification of the Unipolar Atrial Electrogram as a Local Endpoint During Common Atrial Flutter Ablation
    Pambrun, Thomas
    Roig, Jeremie
    Bouzeman, Abdeslam
    Maupas, Eric
    Ciobotaru, Vlad
    Boulenc, Jean-Marc
    Appetiti, Anthony
    Pujadas-Berthault, Penelope
    Rioux, Philippe
    Bortone, Agustin
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (11) : 1196 - 1203
  • [15] Effective Modification to Complex Fractionated Atrial Electrogram by Ablation for Ganglionated Plexus in Patients With Atrial Fibrillation
    Naito, Masaki
    Dote, Yoko
    Hashimoto, Yukihiro
    Fujimoto, Hajime
    Goryo, Yutaka
    Isojima, Takuya
    Suzuki, Megumi
    Iwama, Hajime
    Nakai, Takehito
    Doi, Naofumi
    Hashimoto, Toshio
    CIRCULATION, 2012, 126 (21)
  • [16] Small solitary atrial fractionated electrogram zone as a novel ablation target for persistent atrial fibrillation
    Yamaji, Hirosuke
    Kawafuji, Souhei
    Sano, Masaya
    Higashiya, Shunichi
    Murakami, Takashi
    Kawamura, Hiroshi
    Murakami, Masaaki
    Kamikawa, Shigeshi
    Kusachi, Shozo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (05) : 1130 - 1140
  • [17] Trials and travails of electrogram-guided ablation of chronic atrial fibrillation
    Nademanee, Koonlawee
    CIRCULATION, 2007, 115 (20) : 2592 - 2594
  • [18] Electrogram Coupling as a Measure of Local Conduction during Atrial Fibrillation
    Zeemering, Stef
    Podziemski, Piotr
    van Hunnik, Arne
    Maesen, Bart
    Bonizzi, Pietro
    Schotten, Ulrich
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 813 - 816
  • [19] Evaluating the Effectiveness of Atrial Fibrillation Ablation Guided by Spatiotemporal Electrogram Dispersion
    Liu, Brian
    Nunez-Garcia, Arismendy
    Cao Tran
    Wu, Michael
    CIRCULATION, 2020, 142
  • [20] Autonomic innervation, atrial electrogram morphology, and atrial fibrillation
    Oral, Hakan
    Morady, Fred
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (14) : 1332 - 1334