Preparation of 90Y by the 90Sr-90Y generator for medical purpose

被引:27
|
作者
Malja, S [1 ]
Schomacker, K
Malja, E
机构
[1] Inst Nucl Phys, Tirana, Albania
[2] Inst Nucl Med, Cologne, Germany
[3] Univ La Sapienza, Fac Med & Surg, Rome, Italy
关键词
Chemical purity - Injectables - Labelings - Radiochemical purity - Solution pH;
D O I
10.1023/A:1006743428757
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The production of Y-90 by Sr-90-Y-90 generator was studied. Sr-90 was adsorbed on a column with Aminex A-5 resin. The daughter radionuclide Y-90 was eluted with 0.7M alpha-hydroxyisoburyrate (alpha-HIB, pH 5.4). Radionuclidic, radiochemical and chemical purities were >98% and yield >85%. After converting into chloride form (YCl3)-Y-90-solution (pH:1) was used for preparing injectable yttrium citrate and labeling some other radiopharmaceuticals. Furthermore, a fast ITLC-method for the determination of Sr-90 in Y-90-eluate was developed.
引用
收藏
页码:403 / 406
页数:4
相关论文
共 50 条
  • [21] Simple and safe production of yttrium-90 from a new type of 90Sr/90Y generator
    Du, J
    Chinol, M
    Savonen, A
    Hiltunen, J
    RADIOCHIMICA ACTA, 2005, 93 (02) : 111 - 113
  • [22] NEW SR-90-Y-90 RADIOISOTOPE GENERATOR
    SKRABA, WJ
    ARINO, H
    KRAMER, HH
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1978, 29 (02): : 91 - 96
  • [23] PREPARATION OF A SR-90 Y-90 GENERATOR USING ZIRCONIUM ANTIMONATE
    DASH, A
    BHATTACHARYYA, PK
    APPLIED RADIATION AND ISOTOPES, 1994, 45 (04) : 415 - 417
  • [24] 反相柱式色层分离90Sr-90Y
    谢秀君
    孙秀荣
    原子能科学技术, 1981, (02) : 168 - 171+179
  • [25] Detection of bremsstrahlung radiation of 90Sr-90Y for emergency lung counting
    Ho, A.
    Witharana, S. S. Hakmana
    Jonkmans, G.
    Li, L.
    Surette, R. A.
    Dubeau, J.
    Dai, X.
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (03) : 443 - 449
  • [26] Rapid determination of 90Sr from 90Y in seawater
    M. Tayeb
    X. Dai
    E. C. Corcoran
    D. G. Kelly
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 304 : 1043 - 1052
  • [27] BREMSSTRAHLUNG FROM 90SR- 90Y IN THIN ABSORBERS
    BUSTARD, TS
    SILVERMAN, J
    NUCLEAR SCIENCE AND ENGINEERING, 1967, 27 (03) : 586 - +
  • [28] A complete dosimetric characterization of two 90Sr-90Y dermatologic applicators
    Coelho, T. S.
    Fernandes, M. A. R.
    Yoriyaz, H.
    Antonio, P. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 632 (01): : 147 - 151
  • [29] Rapid determination of 90Sr from 90Y in seawater
    Tayeb, M.
    Dai, X.
    Corcoran, E. C.
    Kelly, D. G.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 304 (03) : 1043 - 1052
  • [30] Conjuctival carcinoma treated by brachytherapy with 90SR/90Y
    Jancar, B.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S252 - S253