Predicting transmitted irradiance through CAD/CAM resin composite crowns in a simulated clinical model

被引:5
|
作者
Butterhof, Maximilian [1 ]
Ilie, Nicoleta [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Operat Restorat Dent Periodontol & Pedodont, Goethestr 70, D-80336 Munich, Germany
关键词
CAD/CAM; Composite crown; Resin-based composite; Correction model; Light curing; Irradiance; Transmission; LIGHT-CURING UNITS; PATIENT SIMULATOR; CONVERSION; RESTORATION; DENTISTRY; ENERGY; CEMENT;
D O I
10.1016/j.dental.2021.03.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To predict the clinically relevant transmitted irradiance that is available for luting when a CAD/CAM restoration is inserted. The influence of irradiance, exposure distance, light curing unit (LCU) angulation and direction of polymerization is analyzed when curing through crowns of different thicknesses. Methods. Three modern CAD/CAM resin-based composites (RBCs) were used to produce 45 crown-shaped specimens. The distance between fissure and crown base was set at 1.0, 1.5 and 2.0 mm (n = 5). Transmitted irradiance, while using a violet-blue LCU, was measured with a photo-spectrometer. 180 exposure conditions per specimen were investigated by variation in LCU curing mode, angulation, exposure distance and direction. Data was analyzed using univariate ANOVA followed by Tukey HSD (alpha = 0.05) and comparison of 95% confidence intervals. Results. The CAD/CAM-RBC's decadic absorption coefficient ranges from 0.317 mm(-1) to 0.387 mm(-1) and the reflection correcting factor for crowns ranges from 0.305 to 0.337. Transmitted irradiance decreases significantly with increasing exposure distance and decreasing incident irradiance. For tilt angles greater than 10 degrees, transmitted irradiances are significantly reduced (-11% for 20 degrees, -23% for 30 degrees). Significantly lowest transmitted irradiances were measured for vestibular curing direction (up to -15%). Significance. A calculation model can predict the transmitted irradiance through a CAD/CAM restoration in dependence of restoration thickness and radiant emittance. The practitioner can be supported by this model to adapt material choice of dental restoration and adhesive system to the individual situation. Variation in exposure conditions shows negative effect on the transmission of light and should be limited. (C) 2021 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:998 / 1008
页数:11
相关论文
共 50 条
  • [1] Predicting the Debonding of CAD/CAM Composite Resin Crowns with AI
    Yamaguchi, S.
    Lee, C.
    Karaer, O.
    Ban, S.
    Mine, A.
    Imazato, S.
    [J]. JOURNAL OF DENTAL RESEARCH, 2019, 98 (11) : 1234 - 1238
  • [2] Letter to the Editor: "Predicting the Debonding of CAD/CAM Composite Resin Crowns with AI"
    Zhang, Y. J.
    Shi, J. Y.
    Zhu, Y.
    Lai, H. C.
    [J]. JOURNAL OF DENTAL RESEARCH, 2020, 99 (02) : 233 - 233
  • [3] Response to the Letter to the Editor: "Predicting the Debonding of CAD/CAM Composite Resin Crowns with AI"
    Yamaguchi, S.
    Lee, C.
    Karaer, O.
    Ban, S.
    Mine, A.
    Imazato, S.
    [J]. JOURNAL OF DENTAL RESEARCH, 2020, 99 (02) : 234 - 234
  • [4] Fatigue resistance of CAD/CAM resin composite molar crowns
    Shembish, Fatma A.
    Tong, Hui
    Kaizer, Marina
    Janal, Malvin N.
    Thompson, Van P.
    Opdam, Niek J.
    Zhang, Yu
    [J]. DENTAL MATERIALS, 2016, 32 (04) : 499 - 509
  • [5] Current status and perspective of CAD/CAM-produced resin composite crowns: a review of clinical effectiveness
    Miura, Shoko
    Fujisawa, Masanori
    [J]. JAPANESE DENTAL SCIENCE REVIEW, 2020, 56 (01) : 184 - 189
  • [6] Fracture force of CAD/CAM resin composite crowns after in vitro aging
    Martin Rosentritt
    Stefanie Krifka
    Thomas Strasser
    Verena Preis
    [J]. Clinical Oral Investigations, 2020, 24 : 2395 - 2401
  • [7] Fatigue behavior and crack initiation of CAD/CAM resin composite molar crowns
    Yamaguchi, Satoshi
    Kani, Renshirou
    Kawakami, Kazuma
    Tsuji, Manami
    Inoue, Sayuri
    Lee, Chunwoo
    Kiba, Wakako
    Imazato, Satoshi
    [J]. DENTAL MATERIALS, 2018, 34 (10) : 1578 - 1584
  • [8] Fracture force of CAD/CAM resin composite crowns after in vitro aging
    Rosentritt, Martin
    Krifka, Stefanie
    Strasser, Thomas
    Preis, Verena
    [J]. CLINICAL ORAL INVESTIGATIONS, 2020, 24 (07) : 2395 - 2401
  • [9] Retention of CAD/CAM resin composite crowns following different bonding protocols
    Nejat, Amir H.
    Lee, Jinwhan
    Shah, Shreya
    Lin, Chee Paul
    Kulkarni, Prajakta
    Chavali, Ramakiran
    Lawson, Nathaniel C.
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2018, 31 (02): : 97 - 102
  • [10] Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns
    Attia, A
    Abdelaziz, KM
    Freitag, S
    Kern, M
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02): : 117 - 123