Predicting transmitted irradiance through CAD/CAM resin composite crowns in a simulated clinical model

被引:5
|
作者
Butterhof, Maximilian [1 ]
Ilie, Nicoleta [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Operat Restorat Dent Periodontol & Pedodont, Goethestr 70, D-80336 Munich, Germany
关键词
CAD/CAM; Composite crown; Resin-based composite; Correction model; Light curing; Irradiance; Transmission; LIGHT-CURING UNITS; PATIENT SIMULATOR; CONVERSION; RESTORATION; DENTISTRY; ENERGY; CEMENT;
D O I
10.1016/j.dental.2021.03.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To predict the clinically relevant transmitted irradiance that is available for luting when a CAD/CAM restoration is inserted. The influence of irradiance, exposure distance, light curing unit (LCU) angulation and direction of polymerization is analyzed when curing through crowns of different thicknesses. Methods. Three modern CAD/CAM resin-based composites (RBCs) were used to produce 45 crown-shaped specimens. The distance between fissure and crown base was set at 1.0, 1.5 and 2.0 mm (n = 5). Transmitted irradiance, while using a violet-blue LCU, was measured with a photo-spectrometer. 180 exposure conditions per specimen were investigated by variation in LCU curing mode, angulation, exposure distance and direction. Data was analyzed using univariate ANOVA followed by Tukey HSD (alpha = 0.05) and comparison of 95% confidence intervals. Results. The CAD/CAM-RBC's decadic absorption coefficient ranges from 0.317 mm(-1) to 0.387 mm(-1) and the reflection correcting factor for crowns ranges from 0.305 to 0.337. Transmitted irradiance decreases significantly with increasing exposure distance and decreasing incident irradiance. For tilt angles greater than 10 degrees, transmitted irradiances are significantly reduced (-11% for 20 degrees, -23% for 30 degrees). Significantly lowest transmitted irradiances were measured for vestibular curing direction (up to -15%). Significance. A calculation model can predict the transmitted irradiance through a CAD/CAM restoration in dependence of restoration thickness and radiant emittance. The practitioner can be supported by this model to adapt material choice of dental restoration and adhesive system to the individual situation. Variation in exposure conditions shows negative effect on the transmission of light and should be limited. (C) 2021 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:998 / 1008
页数:11
相关论文
共 50 条
  • [31] Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras
    de Paula Silveira, Alessandra C.
    Chaves, Sacha B.
    Hilgert, Leandro A.
    Ribeiro, Ana Paula D.
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (03): : 386 - 392
  • [32] Composite resin CAD-CAM restorations for a midline diastema closure: A clinical report
    Vasques, Wesley F.
    Sa, Thamir A.
    Martins, Felipe, V
    Fonseca, Edgard M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 206 - 209
  • [33] Evaluation of the clinical application of personalized 3D printing and CAD/CAM resin crowns to replace stainless steel crowns in paediatric dentistry
    Huang, Huei-Yu
    Yang, Ya-Ting
    Chuang, Chun-Chao
    Shen, Yung-Kang
    Chen, Mu-Hsiung
    Lin, Wei-Chun
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2024,
  • [34] Light irradiance through novel CAD-CAM block materials and degree of conversion of composite cements
    Lise, Diogo Pedrollo
    Van Ende, Annelies
    De Munck, Jan
    Yoshihara, Kumiko
    Nagaoka, Noriyuki
    Cardoso Vieira, Luiz Clovis
    Van Meerbeek, Bart
    DENTAL MATERIALS, 2018, 34 (02) : 296 - 305
  • [35] Influence of the resin cement thickness on the fatigue failure loads of CAD/CAM feldspathic crowns
    May, Liliana Gressler
    Kelly, J. Robert
    Bottino, Marco Antonio
    Hill, Tom
    DENTAL MATERIALS, 2015, 31 (08) : 895 - 900
  • [36] Resin-composite Blocks for Dental CAD/CAM Applications
    Ruse, N. D.
    Sadoun, M. J.
    JOURNAL OF DENTAL RESEARCH, 2014, 93 (12) : 1232 - 1234
  • [37] Potential complications of CAD/CAM-produced resin composite crowns on molars: A retrospective cohort study over four years
    Inomata, Miyu
    Harada, Akio
    Kasahara, Shin
    Kusama, Taro
    Ozaki, Akane
    Katsuda, Yusuke
    Egusa, Hiroshi
    PLOS ONE, 2022, 17 (04):
  • [38] Simulated fatigue resistance of composite resin versus porcelain CAD/CAM overlay restorations on endodontically treated molars
    Magne, Pascal
    Knezevic, Alena
    QUINTESSENCE INTERNATIONAL, 2009, 40 (02): : 125 - 133
  • [39] The influence of FRCs reinforcement on marginal adaptation of CAD/CAM composite resin endocrowns after simulated fatigue loading
    Rocca, Giovanni Tommaso
    Saratti, Carlo Massimo
    Poncet, Antoine
    Feilzer, Albert J.
    Krejci, Ivo
    ODONTOLOGY, 2016, 104 (02) : 220 - 232
  • [40] The influence of FRCs reinforcement on marginal adaptation of CAD/CAM composite resin endocrowns after simulated fatigue loading
    Giovanni Tommaso Rocca
    Carlo Massimo Saratti
    Antoine Poncet
    Albert J. Feilzer
    Ivo Krejci
    Odontology, 2016, 104 : 220 - 232