Fracture force of CAD/CAM resin composite crowns after in vitro aging

被引:23
|
作者
Rosentritt, Martin [1 ]
Krifka, Stefanie [1 ]
Strasser, Thomas [1 ]
Preis, Verena [1 ]
机构
[1] UKR Univ Hosp Regensburg, Dept Prosthet Dent, D-93042 Regensburg, Germany
关键词
CAD; CAM; Resin composite; Resin-based material; Preparation; Fit; CAM bloc; Dental material; TCML; Aging; Storage; MECHANICAL-PROPERTIES; BOND STRENGTH; RESISTANCE; BLOCKS; RESTORATIONS; PERFORMANCE; FATIGUE; SURFACE; TOOTH; WEAR;
D O I
10.1007/s00784-019-03099-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this in vitro study was to investigate the influence of material, preparation, and pre-treatment on the aging and fracture force of CAD/CAM resin composite molar crowns. Materials and methods CAD/CAM molar crowns (n = 80) were milled from four resin composites (Block HC, Shofu; Lava Ultimate, 3 M; Grandio Blocs, Voco; and Tetric CAD, Ivoclar Vivadent, with/without sandblasting). Extracted human teeth were prepared with optimal preparation (height 6-8 mm, angle 6-8 degrees) or worst-case preparation (height 3.5-4 mm, angle 10-15 degrees). Both groups were prepared with a 1-mm deep cervical circular shoulder. Crowns were adhesively bonded after corresponding tooth treatment required for the individual adhesive systems (Table 1). Specimens were aged for 90 days in water storage (37 degrees C) and subsequently subjected to thermal cycling and mechanical loading (TCML 3000 x 5 degrees C/3000 x 55 degrees C, 2 min each cycle, H20 distilled; 1.2 x 10(6) cycles a 50 N, 1.6 Hz). De-bonding and fracture force was determined. Statistics: one-way-ANOVA; post hoc Bonferroni, alpha = 0.05. Results Four crowns of Lava Ultimate with worst-case preparation de-bonded during TCML. Individual crowns without sandblasting treatment (3x Tetric CAD with optimal preparation; 1x Tetric CAD with worst-case preparation) de-bonded during water storage. One crown of Grandio Blocs with optimal preparation showed a small chipping during TCML. All other crowns survived TCML and water storage without failure. Fracture forces differed between 1272 +/- 211 N (Lava Ultimate) and 3061 +/- 521 N (Tetric CAD). All Grandio Blocs and Tetric CAD crowns revealed significantly (p <= 0.023) higher fracture forces than Block HC or Lava Ultimate crowns. No significantly different (p > 0.05) fracture forces were found between optimal or worst-case preparation/fit groups. Conclusions De-bonding during water storage and TCML was dependent on material and crown pre-treatment. Therefore, surface roughening seems strongly required. Fracture forces were not influenced by preparation but by the type of material.
引用
收藏
页码:2395 / 2401
页数:7
相关论文
共 50 条
  • [1] Fracture force of CAD/CAM resin composite crowns after in vitro aging
    Martin Rosentritt
    Stefanie Krifka
    Thomas Strasser
    Verena Preis
    [J]. Clinical Oral Investigations, 2020, 24 : 2395 - 2401
  • [2] Aging and Fracture Resistance of Implant-Supported Molar Crowns with a CAD/CAM Resin Composite Veneer Structure
    Rauch, Angelika
    Heinzmann, Wendy
    Rosentritt, Martin
    Hahnel, Sebastian
    Schmidt, Michael Benno
    Fuchs, Florian
    Koenig, Andreas
    [J]. JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [3] Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns
    Attia, A
    Abdelaziz, KM
    Freitag, S
    Kern, M
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02): : 117 - 123
  • [4] Predicting the Debonding of CAD/CAM Composite Resin Crowns with AI
    Yamaguchi, S.
    Lee, C.
    Karaer, O.
    Ban, S.
    Mine, A.
    Imazato, S.
    [J]. JOURNAL OF DENTAL RESEARCH, 2019, 98 (11) : 1234 - 1238
  • [5] Fatigue resistance of CAD/CAM resin composite molar crowns
    Shembish, Fatma A.
    Tong, Hui
    Kaizer, Marina
    Janal, Malvin N.
    Thompson, Van P.
    Opdam, Niek J.
    Zhang, Yu
    [J]. DENTAL MATERIALS, 2016, 32 (04) : 499 - 509
  • [6] Fracture Resistance of Two Different Composite Resin CAD/CAM Crowns Bonded to Titanium Abutments
    Fernandez-Villar, Sandra
    Cano-Batalla, Jordi
    Cabratosa-Termes, Josep
    Canto-Naves, Oriol
    Arregui, Maria
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (06) : 648 - 655
  • [7] Dimensional changes of CAD/CAM polymer crowns after water aging - An in vitro experiment
    Schepke, U.
    Filius, D.
    Lohbauer, U.
    la Bastide-van Gemert, S.
    Gresnigt, M. M. M.
    Cune, S.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 128
  • [8] Effects of Cuspal Inclination and Luting Agent on Fracture Load Values in Composite Resin CAD/CAM Crowns
    Kuroishi, Gen
    Yotsuya, Mamoru
    Nomoto, Syuntaro
    Hisanaga, Ryuichi
    Sato, Toru
    [J]. BULLETIN OF TOKYO DENTAL COLLEGE, 2022, 63 (02): : 55 - 66
  • [9] Effect of Differences in Axial Thickness and Type of Cement on Fracture Resistance in Composite Resin CAD/CAM Crowns
    Masuda, Tomotoshi
    Nomoto, Syuntaro
    Sato, Toru
    Kanda, Yuuhei
    Sakai, Takanori
    Tsuyuki, Yu
    [J]. BULLETIN OF TOKYO DENTAL COLLEGE, 2019, 60 (01): : 17 - 27
  • [10] Fracture origin and crack propagation of CAD/CAM composite crowns by combining of in vitro and in silico approaches
    Yamaguchi, Satoshi
    Katsumoto, Yu
    Hayashi, Kimiko
    Aoki, Maika
    Kunikata, Miwa
    Nakase, Yutaro
    Lee, Chunwoo
    Imazato, Satoshi
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 112