Determination of cortisol and cortisone in human saliva by a liquid chromatography-tandem mass spectrometry method

被引:12
|
作者
Henriques Vieira, Jose Gilberto [1 ]
Nakamura, Odete Hirata [1 ]
Carvalho, Valdemir Melechko [1 ]
机构
[1] Steroid Labs, Grp Fleury, Sao Paulo, Brazil
关键词
Salivary cortisol; salivary cortisone; mass spectrometry; radioimmunoassay; hypercortisolism screening; CORTICOSTEROID-BINDING GLOBULIN; FREE HORMONE HYPOTHESIS; URINARY FREE CORTISOL; CUSHINGS-SYNDROME; RADIOIMMUNOASSAY; DEXAMETHASONE; SPECIFICITY; DIAGNOSIS; STEROIDS; PLASMA;
D O I
10.1590/0004-2730000003347
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Salivary cortisol measurement plays an important role in the evaluation of adrenal function. Its high correlation with free serum cortisol, the easy of sampling and the limited presence of interfering steroids, generated multiple recent studies of its application, in special in the screening of adrenal hyperfunction. In this paper we present our experience in the development of a high pressure liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for salivary cortisol and cortisone measurement. Materials and methods: For this study we used 181 saliva samples from our routine diagnostic laboratory. The HPLC-MS/MS method was based on a Waters Quattro Premier tandem mass spectrometer with an electrospray probe. After derivatization with hydroxylamine transitions monitored included cortisol and cortisone. An in-house radioimmunoassay (RIA) was used for salivary cortisol results comparison. Results: Functional sensitivity was 24 ng/dL for cortisol and linearity from 24 to 1929 ng/dL. Saliva cortisol values obtained in the 181 samples presented a median of 52 ng/dL with 5-95% percentile of 24 and 374 ng/dL. With the RIA the results were 86, 25 and 436 ng/dL, respectively, with values for RIA being significantly higher (P < 0.0001) and high correlation (r = 0.8312, P < 0.0001). Cortisone measured in 159 samples showed a median of 278 ng/dL, with 5-95% percentile of 100 and 1,133 ng/dL. Correlation with cortisol values was significant (r = 0.820, P < 0.0001). Conclusion: We conclude that the HPLC-MS/MS method compares favorably with the RIA for salivary cortisol measurement, with the additional possibility of concomitant cortisone measurement and the evaluation of 11 beta HSD2 activity.
引用
收藏
页码:844 / 850
页数:7
相关论文
共 50 条
  • [31] Determination of cortisol in hair using liquid chromatography-tandem mass spectrometry: a short review
    Decker Soares, Daniella Rheingantz
    Antunes, Marina Venzon
    Linden, Rafael
    [J]. BIOANALYSIS, 2021, 13 (14) : 1145 - 1155
  • [32] Determination of telmisartan in human plasma by liquid chromatography-tandem mass spectrometry
    Li, PF
    Wang, YW
    Wang, Y
    Tang, YB
    Fawcett, JP
    Cui, YM
    Gu, JK
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2): : 126 - 129
  • [33] Determination of captopril in human plasma by liquid chromatography-tandem mass spectrometry
    Gu, Jingkai
    Cui, Yimin
    [J]. DRUG METABOLISM REVIEWS, 2006, 38 : 142 - 142
  • [34] Determination of captopril in human plasma by liquid chromatography-tandem mass spectrometry
    Zhao Limei
    Hu Ligang
    Jiang Yao
    Wang Jiang
    Wang Ling
    Gu Jingkai
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (11) : 1599 - 1602
  • [35] Determination of olanzapine in human blood by liquid chromatography-tandem mass spectrometry
    Berna, A
    Ackermann, B
    Ruterbories, K
    Glass, S
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (01): : 163 - 168
  • [36] Determination of solifenacin in human plasma by liquid chromatography-tandem mass spectrometry
    Macek, Jan
    Ptacek, Pavel
    Klima, Josef
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3327 - 3330
  • [37] Determination of celecoxib in human plasma by liquid chromatography-tandem mass spectrometry
    Ptacek, Pavel
    Klima, Josef
    Macek, Jan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 899 : 163 - 166
  • [38] Determination of free and total cortisol in plasma and urine by liquid chromatography-tandem mass spectrometry
    Huang, Weili
    Kalhorn, Thomas F.
    Baillie, Mark
    Shen, Danny D.
    Thummel, Kenneth E.
    [J]. THERAPEUTIC DRUG MONITORING, 2007, 29 (02) : 215 - 224
  • [39] Determination of cetirizine in human plasma by liquid chromatography-tandem mass spectrometry
    Eriksen, H
    Houghton, R
    Green, R
    Scarth, J
    [J]. CHROMATOGRAPHIA, 2002, 55 (Suppl 1) : S145 - S149
  • [40] Determination of Tirofiban in human serum by liquid chromatography-tandem mass spectrometry
    Oertel, R
    Köhler, A
    Koster, A
    Kirch, W
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 181 - 185