Topography and longitudinal chromatic aberration characterizations of refractive-diffractive multifocal intraocular lenses

被引:41
|
作者
Loicq, Jerome [1 ]
Willet, Nicolas [2 ]
Gatinel, Damien [3 ]
机构
[1] Univ Liege, STAR Inst, Ctr Spatial Liege, Av Pre Aily, B-4031 Angleur, Belgium
[2] Univ Liege, Dept Chem, Liege, Belgium
[3] Fdn Rothschild Hosp, Paris, France
来源
关键词
EXTENDED DEPTH; PERFORMANCE;
D O I
10.1016/j.jcrs.2019.06.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Most optical systems present chromatic aberration quantified along the optical axis by the longitudinal chromatic aberration (LCA). LCA is controlled by the biomaterial Abbe number combined with diffractive effects, driven by the intraocular lens (IOL) topography. This study experimentally aimed at describing the effect in vitro of LCA in diffractive multifocal IOLs, with the help of dedicated optical benches and topographic characterization. Setting: Centre Spatial de Liege, Belgium. Design: Optical and topology analysis of various multifocal diffractive IOLs. Methods: Seven diffractive multifocal IOLs, available on the market and exhibiting different diffractive profiles, made from various biomaterials, were characterized under different wavelengths. Results: Through-focus modulation transfer function (MTF) curves and IOL diffraction efficiency depends on the incident light wavelength. In this study, the topology properties of various multi-focal IOLs were investigated and their characteristics were correlated to their optical behavior for various wavelengths. Chromatic properties and their origins were then compared. As expected, diffractive and refractive effects were found to act in opposite ways, and could be partially or completely compensated. Conclusions: The LCA of each of the IOLs was evaluated in vitro. In most of the multifocal IOLs studied, some of the foci were found to be refractive, whereas others were diffractive. Although the results were not extrapolated to clinical relevance, it was shown, in some of the cases, that LCA could be fully compensated. (C) 2019 ASCRS and ESCRS
引用
收藏
页码:1650 / 1659
页数:10
相关论文
共 50 条
  • [41] Assessing the optical performance of multifocal (diffractive) intraocular lenses
    Eppig, Timo
    Scholz, Katja
    Langenbucher, Achim
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (05) : 467 - 474
  • [42] Autorefraction after implantation of diffractive multifocal intraocular lenses
    Bissen-Miyajima, Hiroko
    Minami, Keiichiro
    Yoshino, Mami
    Nishimura, Mariko
    Oki, Shinchi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04): : 553 - 556
  • [43] Near vision restoration with refractive lens exchange and pseudoaccommodating and multifocal refractive and diffractive intraocular lenses -: Comparative clinical study
    Alió, JL
    Tavolato, M
    De la Hoz, F
    Claramonte, P
    Rodríguez-Prats, JL
    Galal, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12): : 2494 - 2503
  • [44] Differences of Longitudinal Chromatic Aberration (LCA) between Eyes with Intraocular Lenses from Different Manufacturers
    Nakajima, Masashi
    Hiraoka, Takahiro
    Yamamoto, Toshiya
    Takagi, Seiu
    Hirohara, Yoko
    Oshika, Tetsuro
    Mihashi, Toshifumi
    PLOS ONE, 2016, 11 (06):
  • [45] Spatio-chromatic vision with multifocal diffractive intraocular lens
    Maria S. Millan
    Laura Clavé
    Aurora Torrents
    Jesús Armengol
    Fidel Vega
    Eye and Vision, 10
  • [46] Spatio-chromatic vision with multifocal diffractive intraocular lens
    Millan, Maria S. S.
    Clave, Laura
    Torrents, Aurora
    Armengol, Jesus
    Vega, Fidel
    EYE AND VISION, 2023, 10 (01)
  • [47] LIGA technology for the synthesis of diffractive refractive intraocular lenses
    Reznikova E.F.
    Goldenberg B.G.
    Kondratyev V.I.
    Kulipanov G.N.
    Korolkov V.P.
    Nasyrov R.K.
    Reznikova, E.F. (E.F.Reznikova@inp.nsk.su), 1600, Allerton Press Incorporation (77): : 111 - 115
  • [48] Diffractive-Refractive Intraocular Lenses with Binary Structures
    Lenkova G.A.
    Optoelectronics, Instrumentation and Data Processing, 2018, 54 (5) : 469 - 476
  • [49] The combination of diffractive and refractive multifocal intraocular lenses to provide full visual function after cataract surgery
    Huetz, Werner W.
    Bahner, Katarzyna
    Roehrig, Bernd
    Hengerer, Fritz
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (02) : 370 - 375
  • [50] Long-term experience with mixing and matching refractive array and diffractive CeeOn multifocal intraocular lenses
    Gunenc, Uzeyir
    Celik, Lider
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) : 233 - 242