Topography and longitudinal chromatic aberration characterizations of refractive-diffractive multifocal intraocular lenses

被引:41
|
作者
Loicq, Jerome [1 ]
Willet, Nicolas [2 ]
Gatinel, Damien [3 ]
机构
[1] Univ Liege, STAR Inst, Ctr Spatial Liege, Av Pre Aily, B-4031 Angleur, Belgium
[2] Univ Liege, Dept Chem, Liege, Belgium
[3] Fdn Rothschild Hosp, Paris, France
来源
关键词
EXTENDED DEPTH; PERFORMANCE;
D O I
10.1016/j.jcrs.2019.06.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Most optical systems present chromatic aberration quantified along the optical axis by the longitudinal chromatic aberration (LCA). LCA is controlled by the biomaterial Abbe number combined with diffractive effects, driven by the intraocular lens (IOL) topography. This study experimentally aimed at describing the effect in vitro of LCA in diffractive multifocal IOLs, with the help of dedicated optical benches and topographic characterization. Setting: Centre Spatial de Liege, Belgium. Design: Optical and topology analysis of various multifocal diffractive IOLs. Methods: Seven diffractive multifocal IOLs, available on the market and exhibiting different diffractive profiles, made from various biomaterials, were characterized under different wavelengths. Results: Through-focus modulation transfer function (MTF) curves and IOL diffraction efficiency depends on the incident light wavelength. In this study, the topology properties of various multi-focal IOLs were investigated and their characteristics were correlated to their optical behavior for various wavelengths. Chromatic properties and their origins were then compared. As expected, diffractive and refractive effects were found to act in opposite ways, and could be partially or completely compensated. Conclusions: The LCA of each of the IOLs was evaluated in vitro. In most of the multifocal IOLs studied, some of the foci were found to be refractive, whereas others were diffractive. Although the results were not extrapolated to clinical relevance, it was shown, in some of the cases, that LCA could be fully compensated. (C) 2019 ASCRS and ESCRS
引用
收藏
页码:1650 / 1659
页数:10
相关论文
共 50 条
  • [1] In vivo measurement of longitudinal chromatic aberration with multifocal diffractive intraocular lenses.
    Vinas, Maria
    Gonzalez-Ramos, Ana
    Dorronsoro, Carlos
    Akondi, Vyas
    Garzon, Nuria
    Poyales, Francisco
    Marcos, Susana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [2] Chromatic aberration and polychromatic image quality with diffractive multifocal intraocular lenses
    Ravikumar, Sowmya
    Bradley, Arthur
    Thibos, Larry N.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07): : 1192 - 1204
  • [3] Optics design of refractive-diffractive elimination chromatic aberration system
    Shen Junxin
    Liu Dong mei
    Sun Yanjun
    DESIGN, MANUFACTURING, AND TESTING OF MICRO- AND NANO-OPTICAL DEVICES AND SYSTEMS, 2007, 6724
  • [4] On the longitudinal chromatic aberration of the intraocular lenses
    Siedlecki, Damian
    Ginis, Harilaos S.
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (10) : 984 - 989
  • [5] Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs
    Artigas, Jose M.
    Menezo, Jose L.
    Peris, Cristina
    Felipe, Adelina
    Diaz-Llopis, Manuel
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12): : 2111 - 2117
  • [6] In Vivo Measurement of Longitudinal Chromatic Aberration in Patients Implanted With Trifocal Diffractive Intraocular Lenses
    Vinas, Maria
    Gonzalez-Ramos, Ana
    Dorronsoro, Carlos
    Akondi, Vyas
    Garzon, Nuria
    Poyales, Francisco
    Marcos, Susana
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (11) : 736 - +
  • [7] Polychromatic Image Performance of Diffractive Bifocal Intraocular Lenses: Longitudinal Chromatic Aberration and Energy Efficiency
    Millan, Maria S.
    Vega, Fidel
    Rios-Lopez, Inmaculada
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (04) : 2021 - 2028
  • [8] In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: Impact of tilt and decentration
    Montes-Mico, Robert
    Lopez-Gil, Norberto
    Perez-Vives, Cari
    Bonaque, Sergio
    Ferrer-Blasco, Teresa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09): : 1657 - 1663
  • [9] Combining Zonal Refractive and Diffractive Aspheric Multifocal Intraocular Lenses
    Munoz, Gonzalo
    Albarran-Diego, Cesar
    Javaloy, Jaime
    Sakla, Hani F.
    Cervino, Alejandro
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) : 174 - 181
  • [10] Comparison of Diffractive and Refractive Multifocal Intraocular Lenses in Presbyopia Treatment
    Barisic, Ante
    Dekaris, Iva
    Gabric, Nikica
    Bohac, Maja
    Romac, Ivana
    Mravicic, Ivana
    Lazic, Ratimir
    COLLEGIUM ANTROPOLOGICUM, 2008, 32 : 27 - 31