Use of low-coherence speckled speckles for bioflow measurements

被引:9
|
作者
Ulyanov, SS [1 ]
Tuchin, VV [1 ]
机构
[1] Saratov NG Chernyshevskii State Univ, Dept Opt, Saratov 410026, Russia
关键词
D O I
10.1364/AO.39.006385
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Formation of speckled speckles in the case of biflow perfusion by partially coherent light was considered. Dependencies of statistical characteristics of low-coherence biospeckles with a small number of scatterers on the scattering properties of the how and on the coherence length of incident light were analyzed. It was shown that the value of the Doppler bandwidth in the scattered light essentially depends on the ratio between the coherence length and the average size of the dow's inhomogeneities. A procedure for reconstructing velocity distribution in a single blood vessel was suggested. (C) 2000 Optical Society of America. OCIS codes: 170.0170, 290.0290.
引用
收藏
页码:6385 / 6389
页数:5
相关论文
共 50 条
  • [41] Dynamically enhanced low-coherence interferometry
    Mitsui, Takahisa
    Aoki, Kenichiro
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (09):
  • [42] Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers
    Can, Ertugrul
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (04) : 288 - 292
  • [43] New remote length measurements with optical fiber using a low-coherence tandem interferometer
    Hirai, A
    Matsumoto, H
    [J]. OPTICS FOR THE QUALITY OF LIFE, PTS 1 AND 2, 2003, 4829 : 930 - 931
  • [44] Comparability of anterior chamber depth measurements with partial coherence interferometry and optical low-coherence reflectometry in pseudophakic eyes
    Luft, Nikolaus
    Hirnschall, Nino
    Farrokhi, Sanaz
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08): : 1678 - 1684
  • [45] In vivo low-coherence spectroscopic measurements of local hemoglobin absorption spectra in human skin
    Bosschaart, Nienke
    Faber, Dirk J.
    van Leeuwen, Ton G.
    Aalders, Maurice C. G.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (10)
  • [46] Intrasession Repeatability of Biometric Measurements Obtained with a Low-Coherence Interferometry System in Pseudophakic Eyes
    Fukumitsu, Hideki
    Camps, Vicent J.
    Pinero, David P.
    [J]. CURRENT EYE RESEARCH, 2020, 45 (02) : 221 - 226
  • [47] Low-coherence fiber-optic sensor with a large numerical aperture for topographic measurements
    Windecker, R
    Fleischer, M
    Tiziani, HJ
    [J]. APPLIED OPTICS, 1998, 37 (19): : 4080 - 4083
  • [48] The use of thin diamond films in fiber-optic low-coherence interferometers
    Milewska, D.
    Karpienko, K.
    [J]. 39TH INTERNATIONAL MICROELECTRONICS AND PACKAGING IMAPS POLAND 2015 CONFERENCE, 2016, 104
  • [49] Accurate remote distance sensing by use of low-coherence interferometry: An industrial application
    Laser Research Center, Vilnius University, Saulétekio al. 10, Vilnius LT-2040, Lithuania
    不详
    [J]. Appl. Opt., 28 (6729-6733):
  • [50] The use of parabolic mirrors in combined low-coherence and confocal refractive index measurement
    Francis, Daniel
    Ford, Helen D.
    Hallam, Jonathan M.
    Tatam, Ralph P.
    [J]. OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION XI, 2019, 11056