On the relevance of modulation transfer function measurements in digital mammography quality control

被引:5
|
作者
Wigati, Kristina T. [1 ,2 ]
Marshall, Nicholas W. [1 ,3 ]
Lemmens, Kim [3 ]
Binst, Joke [3 ]
Jacobs, Annelies [3 ]
Cockmartin, Lesley [1 ,3 ]
Zhang, Guozhi [3 ]
Vancoillie, Liesbeth [1 ,3 ]
Petrov, Dimitar [1 ,3 ]
Vandenbroucke, Dirk A. N. [4 ]
Soejoko, Djarwani S. [2 ]
Bosmans, Hilde [1 ,3 ]
机构
[1] Katholieke Univ Leuven, Dept Imaging & Pathol, Leuven, Belgium
[2] Univ Indonesia, Dept Phys, Depok, Indonesia
[3] UZ Leuven, Dept Radiol, Leuven, Belgium
[4] Agfa Healthcare NV, Mortsel, Belgium
关键词
sharpness; modulation transfer function; image quality; digital mammography; quality control; IMAGE QUALITY; PERFORMANCE; DETECTORS; PHANTOM; MTF;
D O I
10.1117/1.JMI.8.2.023505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The relevance of presampling modulation transfer function (MTF) measurements in digital mammography (DM) quality control (QC) is examined. Two studies are presented: a case study on the impact of a reduction in MTF on the technical image quality score and analysis of the robustness of routine QC MTF measurements. Approach: In the first study, two needle computed radiography (CR) plates with identical sensitivities were used with differences in the 50% point of the MTF (f(MTF0.5)) larger than the limiting value in the European guidelines (>10% change between successive measurements). Technical image quality was assessed via threshold gold thickness of the CDMAM phantom and threshold microcalcification diameter of the L1 structured phantom. For the second study, presampling MTF results from 595 half-yearly QC tests of 55 DM systems (16 types, six manufacturers) were analyzed for changes from the baseline value and changes in fMTF0.5 between successive tests. Results: A reduction of 20% in f(MTF0.5) of the two CR plates was observed. There was a tendency to a lower score for task-based metrics, but none were significant. Averaging over 55 systems, the absolute relative change in f(MTF0.5) between consecutive tests (with 95% confidence interval) was 3% (2.5% to 3.4%). Analysis of the maximum relative change from baseline revealed changes of up to -10% for one a-Se based system and -15% for a group of CsI-based systems. Conclusions: A limit of 10% is a relevant action level for investigation. If exceeded, then the impact on performance has to be verified with extra metrics. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Modulation transfer function of a selenium-based digital mammography system
    Hoheisel, M.
    Baetz, L.
    Mertelmeier, T.
    Giersch, J.
    Korn, A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1118 - 1122
  • [2] Modulation transfer function of a selenium-based digital mammography system
    Hoheisel, M
    Bätz, L
    Mertelmeier, T
    Giersch, J
    Korn, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3589 - 3593
  • [3] Effect of the Edge Tool on Modulation Transfer Function Measurement in Digital Mammography
    Karaaslan, Melike Kaya
    Gundogdu, Ozcan
    Muzoglu, Nedim
    TIP TEKNOLOJILERI KONGRESI (TIPTEKNO'21), 2021,
  • [5] Digital mammography - Quality Control and guidelines
    Heid, Patrice
    IMAGERIE DE LA FEMME, 2006, 16 (03) : 175 - 180
  • [6] Digital mammography quality control and accreditation
    Butler, P.
    MEDICAL PHYSICS, 2006, 33 (06) : 2178 - 2178
  • [7] The modulation transfer function: A simplified procedure for computer- aided quality evaluation in mammography
    Department of Electrical Engineering, Escola de Engenharia de S. Carlos, Universidade de São Paulo
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    IEEE ENG. MED. BIOL. MAG., 4 (93-101):
  • [8] Automated quality control program for digital mammography
    Bloomquist, AK
    Yaffe, MJ
    Shen, S
    Hendrick, RE
    Pisano, ED
    RADIOLOGY, 2002, 225 : 546 - 546
  • [9] A harmonized quality control program for digital mammography
    Yaffe, Martin
    Mawdsley, Gordon
    Bloomquist, Aili
    DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 585 - 592
  • [10] Effect of X-Ray Tube Voltage and Radiation Dose on Modulation Transfer Function in Digital Mammography
    Karaaslan, Melike Kaya
    Avci, Onur Muhammed
    Muzoglu, Nedim
    Gundogdu, Ozcan
    2022 MEDICAL TECHNOLOGIES CONGRESS (TIPTEKNO'22), 2022,