On the relevance of modulation transfer function measurements in digital mammography quality control

被引:5
|
作者
Wigati, Kristina T. [1 ,2 ]
Marshall, Nicholas W. [1 ,3 ]
Lemmens, Kim [3 ]
Binst, Joke [3 ]
Jacobs, Annelies [3 ]
Cockmartin, Lesley [1 ,3 ]
Zhang, Guozhi [3 ]
Vancoillie, Liesbeth [1 ,3 ]
Petrov, Dimitar [1 ,3 ]
Vandenbroucke, Dirk A. N. [4 ]
Soejoko, Djarwani S. [2 ]
Bosmans, Hilde [1 ,3 ]
机构
[1] Katholieke Univ Leuven, Dept Imaging & Pathol, Leuven, Belgium
[2] Univ Indonesia, Dept Phys, Depok, Indonesia
[3] UZ Leuven, Dept Radiol, Leuven, Belgium
[4] Agfa Healthcare NV, Mortsel, Belgium
关键词
sharpness; modulation transfer function; image quality; digital mammography; quality control; IMAGE QUALITY; PERFORMANCE; DETECTORS; PHANTOM; MTF;
D O I
10.1117/1.JMI.8.2.023505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The relevance of presampling modulation transfer function (MTF) measurements in digital mammography (DM) quality control (QC) is examined. Two studies are presented: a case study on the impact of a reduction in MTF on the technical image quality score and analysis of the robustness of routine QC MTF measurements. Approach: In the first study, two needle computed radiography (CR) plates with identical sensitivities were used with differences in the 50% point of the MTF (f(MTF0.5)) larger than the limiting value in the European guidelines (>10% change between successive measurements). Technical image quality was assessed via threshold gold thickness of the CDMAM phantom and threshold microcalcification diameter of the L1 structured phantom. For the second study, presampling MTF results from 595 half-yearly QC tests of 55 DM systems (16 types, six manufacturers) were analyzed for changes from the baseline value and changes in fMTF0.5 between successive tests. Results: A reduction of 20% in f(MTF0.5) of the two CR plates was observed. There was a tendency to a lower score for task-based metrics, but none were significant. Averaging over 55 systems, the absolute relative change in f(MTF0.5) between consecutive tests (with 95% confidence interval) was 3% (2.5% to 3.4%). Analysis of the maximum relative change from baseline revealed changes of up to -10% for one a-Se based system and -15% for a group of CsI-based systems. Conclusions: A limit of 10% is a relevant action level for investigation. If exceeded, then the impact on performance has to be verified with extra metrics. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:26
相关论文
共 50 条
  • [21] Digital mammography and the Mammography Quality Standards Act
    Chakrabarti, K
    Showalter, CK
    Fischer, RA
    JOURNAL OF DIGITAL IMAGING, 1997, 10 (03) : 140 - 141
  • [22] Digital mammography and the mammography quality standards act
    Kish Chakrabarti
    Charles K. Showalter
    Ruth A. Fischer
    Journal of Digital Imaging, 1997, 10 : 140 - 141
  • [23] Digital mammography and the Mammography Quality Standards Act
    Chakrabarti, Kish
    Showalter, Charles K.
    Fischer, Ruth A.
    Journal of Digital Imaging, 1997, 10 (3 Suppl 1): : 140 - 141
  • [24] A task-based quality control metric for digital mammography
    Bloomquist, A. K. Maki
    Mainprize, J. G.
    Mawdsley, G. E.
    Yaffe, M. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21): : 6621 - 6635
  • [25] Implementation of the 2016 ACR Digital Mammography Quality Control Manual
    Butler, Priscilla
    Pfeiffer, D.
    Berns, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 3237 - 3237
  • [26] Method of measuring NEQ as a quality control metric for digital mammography
    Bloomquist, Aili K.
    Mainprize, James G.
    Mawdsley, Gordon E.
    Yaffe, Martin J.
    MEDICAL PHYSICS, 2014, 41 (03)
  • [27] A first experience of quality control in full field digital mammography
    Gennaro, G
    Baldelli, P
    di Maggio, C
    Taibi, A
    Gambaccini, M
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 81 - 84
  • [28] Mammography Accreditation Phantom Variation: Effects On Quality Control Measurements
    Fisher, R.
    Hulme, K.
    MEDICAL PHYSICS, 2017, 44 (06) : 3103 - 3103
  • [29] Study on Chromatic Modulation Transfer Function of Digital Camera
    Liu, Wei
    Chen, Guangxue
    Jin, Yang
    Song, Yuehong
    ADVANCED GRAPHIC COMMUNICATIONS, PACKAGING TECHNOLOGY AND MATERIALS, 2016, 369 : 285 - 294
  • [30] Interlaboratory comparison of photographic modulation transfer function measurements
    Thompson, AD
    Kane, PJ
    OPTICAL ENGINEERING, 1998, 37 (05) : 1627 - 1632