Multi-objective optimization of an innovative power-cooling integrated system based on gas turbine cycle with compressor inlet air precooling, Kalina cycle and ejector refrigeration cycle

被引:16
|
作者
Du, Yang [1 ,2 ]
Jiang, Nan [1 ]
Zhang, Yicen [1 ]
Wang, Xu [1 ]
Zhao, Pan [1 ]
Wang, Jiangfeng [1 ]
Dai, Yiping [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Sch Energy & Power Engn, Xian 710049, Shaanxi, Peoples R China
[2] Tech Univ Denmark, Dept Energy Convers & Storage, DK-4000 Roskilde, Denmark
关键词
Ejector refrigeration cycle; Kalina cycle; Air precooling; Multi-objective optimization; Gas turbine; WASTE HEAT-RECOVERY; PERFORMANCE ANALYSIS; THERMODYNAMIC ANALYSIS; DESIGN; DRIVEN; ORC;
D O I
10.1016/j.enconman.2021.114473
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, an innovative power-cooling integrated system based on gas turbine, Kalina cycle system, ejector refrigeration cycle (GT-KCS-ERC) is proposed. The ERC driven by GT flue gas and KCS low concentration liquid waste heat is utilized to precool GT inlet air for producing extra power from GT and provide some cooling capacity for users, simultaneously. The comprehensive thermodynamic and thermo-economic analyses are conducted to demonstrate the feasibility of novel GT-KCS-ERC hybrid system by comparing with standalone GT-KCS system. Furthermore, the effects of seven key operation parameters on the system performances are investigated. The multi-objective optimization of GT-KCS-ERC hybrid system and standalone GT-KCS system is carried out through Non-dominated Sorting Genetic Algorithm-II, in which the objectives are maximum total energy efficiency and minimum levelized cost of energy (LCOE). The results show that the total energy efficiency of GTKCS-ERC increases with increasing pinch point temperature difference of boiler Delta TKCS,boi and decreasing ammonia concentration of working solution in KCS, while that of standalone GT-KCS shows opposite trends. The LCOE of GT-KCS-ERC is lower than that of standalone GT-KCS as Delta TKCS,boi is larger than 21 degrees C or turbine inlet pressure of KCS is higher than 6.6 MPa. The optimal saturated evaporator temperature and pressure ratio of vapor generator to condenser in ERC with optimal refrigerant of R290 are 0 degrees C and 4, respectively. Under the optimal condition, the GT-KCS-ERC with an ERC secondary flow split ratio of 0.162 for precooling GT inlet air presents 219.4 kW more net power and 764.2 kW more cooling capacity than standalone GT-KCS system. The LCOE decreases by 0.802% and total energy efficiency increases by 5.347% in novel GT-KCS-ERC system comparing with standalone GT-KCS system.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Thermo-economic evaluation and multi-objective optimization of a waste heat driven combined cooling and power system based on a modified Kalina cycle
    Kalan, Ali Shokri
    Ghiasirad, Hamed
    Saray, Rahim Khoshbakhti
    Mirmasoumi, Siamak
    ENERGY CONVERSION AND MANAGEMENT, 2021, 247 (247)
  • [22] Multi-objective optimization and life cycle assessment of an integrated system combining LiBr/H2O absorption chiller and Kalina cycle
    Xie, Nan
    Liu, Zhiqiang
    Luo, Zhengyi
    Ren, Jingzheng
    Deng, Chengwei
    Yang, Sheng
    ENERGY CONVERSION AND MANAGEMENT, 2020, 225
  • [23] Multi-objective optimization of hydrogen production system based on the combined supercritical cycle and gas turbine plant
    Li Z.
    Qi X.
    Huang M.
    Ma Z.
    Kochan O.
    Yang C.
    Siarry P.
    Chemosphere, 2023, 338
  • [24] Multi-objective Optimization of Cogeneration of Power and Heat in a Combined Gas Turbine and Organic Rankine Cycle
    Mansureh, Khaljani
    Rahim, Khoshbakhti Saray
    Keyvan, Bahlouli
    EXERGY FOR A BETTER ENVIRONMENT AND IMPROVED SUSTAINABILITY 1: FUNDAMENTALS, 2018, : 843 - 861
  • [25] Exergoeconomic and Exergoenvironmental Analysis of a Novel Power and Cooling Cogeneration System Based on Organic Rankine Cycle and Ejector Refrigeration Cycle
    Tao, Jinke
    Wang, Huitao
    Wang, Jianjun
    Feng, Chaojun
    ENERGIES, 2022, 15 (21)
  • [26] Exergoeconomic analysis and multi-objective optimization of an ejector refrigeration cycle powered by an internal combustion (HCCI) engine
    Sadeghi, Mohsen
    Mahmoudi, S. M. S.
    Saray, R. Khoshbakhti
    ENERGY CONVERSION AND MANAGEMENT, 2015, 96 : 403 - 417
  • [27] Sensitivity analysis and multi-objective optimization of organic Rankine cycle integrated with vapor compression refrigeration system
    Ashwni
    Ahmad, Sherwani
    Tiwari, Deepak
    Anil, Kumar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021,
  • [28] Multi-objective particle swarm optimization of regenerative intercooled gas turbine cycle
    1600, Science and Engineering Research Support Society, 20 Virginia Court, Sandy Bay, Tasmania, Australia (06):
  • [29] INTEGRATED MODELLING AND MULTI-OBJECTIVE OPTIMIZATION OF ORGANIC RANKINE CYCLE BASED ON RADIAL INFLOW TURBINE
    Rahbara, K.
    Mahmoud, S.
    Al-Dadah, R. K.
    Moazami, N.
    ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2015, VOL 3, 2015,
  • [30] Energy, exergy, exergoeconomic, economic, and environmental analyses and multi-objective optimization of a novel combined cooling and power system with dual-pressure Kalina cycle-absorption refrigeration
    Yang, Xinle
    Yan, Zhenchao
    Bu, Shujuan
    Li, Weikang
    Yu, Ning
    Su, Chang
    Lu, Shengdong
    Wang, Xin
    Energy Conversion and Management, 315