4D in-vivo dosimetry in radiotherapy

被引:1
|
作者
Cygler, J.
Saoudi, A.
Cherpak, A.
Ding, W.
Ashton, R.
机构
[1] Ottawa Hosp, Reg Canc Ctr, Ottawa, ON, Canada
[2] Best Med Canada Ltd, Ottawa, ON, Canada
关键词
D O I
10.1118/1.2760651
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a novel concept of 4D in‐vivo dosimetry in radiotherapy. Method and Materials: A prototype of a new system capable of simultaneous measurement of dose and spatial position has been developed. The device, controlled by a computer, consists of a probe combining two technologies: MOSFET radiation detector coupled with a magnetic positioning device. Special software that allows sampling position and dose in user defined time intervals has been developed. The preliminary tests of the new device have been performed. The tests included measurements of spatial position accuracy as well as a dosimetric evaluation of the device in [formula omitted] beam from a Theratron teletherapy unit. In addition, some tests were performed in a 6 MV beam from a Siemens linear accelerator to assess if the electromagnetic field from the linac interferes with the performance of the 4D dosimeter system. Results: Measurements of the angular response of the probe over 3600 range in a [formula omitted] beam have been found isotropic within +/− 7%. Measurements of dose profiles in air in a [formula omitted] beam have been performed. They agree very well with the measurements performed using RFA300 dosimeter system and a high quality photon diode. Tests conducted in a 6 MV beam indicate that there is no interference from the linac electromagnetic field on the performance of this new 4D dosimeter system. Conclusion: The results of the preliminary tests indicate that the device can be used for in‐vivo dosimetry in a [formula omitted] and high energy beams from linear accelerators. Future work will involve technical improvements to the device, experiments in a 4D phantom and finally patient in‐vivo dosimetry. This project has been supported by HTX‐OCE‐IRAP grant. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2402 / 2402
页数:1
相关论文
共 50 条
  • [41] Comparison of RADPOS 4D in Vivo Dosimetry System with Phillips Bellows and Varian RPM Systems
    Cherpak, A.
    Andrusyk, S.
    Pourmoghaddas, A.
    Wells, G.
    Cygler, J.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2540 - +
  • [42] 3D AND TIME RESOLVED (4D) DOSIMETRY
    Mijnheer, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S126 - S126
  • [43] A tool for the interactive analysis and exploration of in-vivo haemodynamics from 4D PC MRI
    Johann B Drexl
    Anja Hennemuth
    Sebastian Meier
    Ramona Lorenz
    Jelena Bock
    Andreas Harloff
    Michael Markl
    Horst K Hahn
    [J]. Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [44] In-Vivo Clinical Validation of Cardiac Deformation and Strain Measurements from 4D Ultrasound
    Po, Ming Jack
    Lorsakul, Auranuch
    Duan, Qi
    Yeroushalmi, Kevin J.
    Hyodo, Eiichi
    Oe, Yukiko
    Homma, Shunichi
    Laine, Andrew F.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 41 - 44
  • [45] A deformable head and neck phantom with in-vivo dosimetry for adaptive radiotherapy quality assurance
    Graves, Yan Jiang
    Smith, Arthur-Allen
    Mcilvena, David
    Manilay, Zherrina
    Lai, Yuet Kong
    Rice, Roger
    Mell, Loren
    Jia, Xun
    Jiang, Steve B.
    Cervino, Laura
    [J]. MEDICAL PHYSICS, 2015, 42 (04) : 1490 - 1497
  • [46] Comparison of pre-treatment and in-vivo dosimetry for advanced radiotherapy of prostate cancer
    Bartnikowska, Agnieszka
    Cieslik, Grzegorz
    Mlodzik, Mateusz
    Garcia-Argibay, Miguel
    Pract, Rep
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (02) : 189 - 197
  • [47] Dose mapping: Validation in 4D dosimetry with measurements and application in radiotherapy follow-up evaluation
    Zhang, Geoffrey G.
    Huang, Tzung-Chi
    Forster, Ken M.
    Lin, Kang-Ping
    Stevens, Craig
    Harris, Eleanor
    Guerrero, Thomas
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2008, 90 (01) : 25 - 37
  • [48] Time-resolved dosimetry for validation of 4D dose calculation in PBS proton beam radiotherapy
    Kostiukhina, N.
    Palmans, H.
    Stock, M.
    Georg, D.
    Knaeusl, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S122 - S123
  • [49] Establishing a framework to implement 4D XCAT Phantom for 4D radiotherapy research
    Panta, Raj K.
    Segars, Paul
    Yin, Fang-Fang
    Cai, Jing
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2012, 8 (04) : 565 - 570
  • [50] In-vivo dosimetry: Possibilities and Pitfalls
    Hansen, V. N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S233 - S233