4D in-vivo dosimetry in radiotherapy

被引:1
|
作者
Cygler, J.
Saoudi, A.
Cherpak, A.
Ding, W.
Ashton, R.
机构
[1] Ottawa Hosp, Reg Canc Ctr, Ottawa, ON, Canada
[2] Best Med Canada Ltd, Ottawa, ON, Canada
关键词
D O I
10.1118/1.2760651
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a novel concept of 4D in‐vivo dosimetry in radiotherapy. Method and Materials: A prototype of a new system capable of simultaneous measurement of dose and spatial position has been developed. The device, controlled by a computer, consists of a probe combining two technologies: MOSFET radiation detector coupled with a magnetic positioning device. Special software that allows sampling position and dose in user defined time intervals has been developed. The preliminary tests of the new device have been performed. The tests included measurements of spatial position accuracy as well as a dosimetric evaluation of the device in [formula omitted] beam from a Theratron teletherapy unit. In addition, some tests were performed in a 6 MV beam from a Siemens linear accelerator to assess if the electromagnetic field from the linac interferes with the performance of the 4D dosimeter system. Results: Measurements of the angular response of the probe over 3600 range in a [formula omitted] beam have been found isotropic within +/− 7%. Measurements of dose profiles in air in a [formula omitted] beam have been performed. They agree very well with the measurements performed using RFA300 dosimeter system and a high quality photon diode. Tests conducted in a 6 MV beam indicate that there is no interference from the linac electromagnetic field on the performance of this new 4D dosimeter system. Conclusion: The results of the preliminary tests indicate that the device can be used for in‐vivo dosimetry in a [formula omitted] and high energy beams from linear accelerators. Future work will involve technical improvements to the device, experiments in a 4D phantom and finally patient in‐vivo dosimetry. This project has been supported by HTX‐OCE‐IRAP grant. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2402 / 2402
页数:1
相关论文
共 50 条
  • [21] Anorectal irradiation in pelvic radiotherapy: An assessment using in-vivo dosimetry
    Hayne, D
    Johnson, U
    D'Souza, D
    Payne, H
    Boulos, PB
    [J]. BRITISH JOURNAL OF CANCER, 2000, 83 : 46 - 46
  • [22] DETECTION OF ERRORS IN INDIVIDUAL PATIENTS IN RADIOTHERAPY BY SYSTEMATIC IN-VIVO DOSIMETRY
    NOEL, A
    ALETTI, P
    BEY, P
    MALISSARD, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 1995, 34 (02) : 144 - 151
  • [23] Anorectal irradiation in pelvic radiotherapy: An assessment using in-vivo dosimetry
    Hayne, D
    Johnson, U
    D'Souza, D
    Boulos, PB
    Payne, H
    [J]. CLINICAL ONCOLOGY, 2001, 13 (02) : 126 - 129
  • [24] Impact of Intrafractional Motion On TomoTherapy Stereotactic Body Radiotherapy (SBRT) 4D Dosimetry
    Lian, J.
    Matney, J.
    Chao, E.
    Chang, S.
    Zagar, T.
    Wang, A.
    Chera, B.
    Das, S.
    Schreiber, E.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3204 - 3204
  • [25] Respiratory gated radiotherapy: the 4D radiotherapy
    Giraud, P
    Simon, L
    Saliou, M
    Reboul, F
    Garcia, R
    Carrie, C
    Lerolle, U
    Rosenwald, JC
    Cosset, JM
    [J]. BULLETIN DU CANCER, 2005, 92 (01) : 83 - 89
  • [26] A new radiotherapy technique: the 4D radiotherapy
    Simon, L
    Giraud, P
    Servois, V
    Rosenwald, J
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S231 - S232
  • [27] Implementing 4D XCAT Phantom for 4D Radiotherapy Research
    Panta, R.
    Segars, W.
    Yin, F.
    Cai, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3686 - 3686
  • [28] THE ROLE OF IN-VIVO DOSIMETRY
    GARAVAGLIA, G
    JOHANSSON, KA
    LEUNENS, G
    MIJNHEER, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 281 - 282
  • [29] IN-VIVO DOSIMETRY IN RAPIDARC
    Slosarek, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : XXIII - XXIV
  • [30] In-vivo dosimetry in brachytherapy
    Cygler, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S55 - S55