4D in-vivo dosimetry in radiotherapy

被引:1
|
作者
Cygler, J.
Saoudi, A.
Cherpak, A.
Ding, W.
Ashton, R.
机构
[1] Ottawa Hosp, Reg Canc Ctr, Ottawa, ON, Canada
[2] Best Med Canada Ltd, Ottawa, ON, Canada
关键词
D O I
10.1118/1.2760651
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a novel concept of 4D in‐vivo dosimetry in radiotherapy. Method and Materials: A prototype of a new system capable of simultaneous measurement of dose and spatial position has been developed. The device, controlled by a computer, consists of a probe combining two technologies: MOSFET radiation detector coupled with a magnetic positioning device. Special software that allows sampling position and dose in user defined time intervals has been developed. The preliminary tests of the new device have been performed. The tests included measurements of spatial position accuracy as well as a dosimetric evaluation of the device in [formula omitted] beam from a Theratron teletherapy unit. In addition, some tests were performed in a 6 MV beam from a Siemens linear accelerator to assess if the electromagnetic field from the linac interferes with the performance of the 4D dosimeter system. Results: Measurements of the angular response of the probe over 3600 range in a [formula omitted] beam have been found isotropic within +/− 7%. Measurements of dose profiles in air in a [formula omitted] beam have been performed. They agree very well with the measurements performed using RFA300 dosimeter system and a high quality photon diode. Tests conducted in a 6 MV beam indicate that there is no interference from the linac electromagnetic field on the performance of this new 4D dosimeter system. Conclusion: The results of the preliminary tests indicate that the device can be used for in‐vivo dosimetry in a [formula omitted] and high energy beams from linear accelerators. Future work will involve technical improvements to the device, experiments in a 4D phantom and finally patient in‐vivo dosimetry. This project has been supported by HTX‐OCE‐IRAP grant. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2402 / 2402
页数:1
相关论文
共 50 条
  • [1] 4D in-vivo dosimetry in radiotherapy
    Cherpak, A. J.
    Buckley, L.
    Ding, W.
    Ashton, R.
    Cygler, J. E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S52 - S52
  • [2] CLINICAL EVALUATION OF A NOVEL 4D IN-VIVO DOSIMETRY SYSTEM FOR LUNG CANCER RADIOTHERAPY
    Perry, G.
    Cherpak, A.
    Cygler, J. E.
    Andrusyk, S.
    Panarotto, J.
    Macrae, R.
    Lochrin, C.
    [J]. LUNG CANCER, 2009, 64 : S51 - S51
  • [3] 4D dosimetry and motion management in clinical radiotherapy
    Back, S. A. J.
    Franich, R. D.
    Edvardsson, A.
    Ceberg, S.
    [J]. 10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [4] Development of a 4D dosimetry simulation system in radiotherapy
    Wu, Q. Jackie
    Thongphiew, Danthai
    Wang, Zhiheng
    Willett, Christopher
    Marks, Lawrence
    Yin, Fang-Fang
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 230 - 244
  • [5] Evaluation of a novel 4D in vivo dosimetry system
    Cherpak, A.
    Ding, W.
    Hallil, A.
    Cygler, J. E.
    [J]. MEDICAL PHYSICS, 2009, 36 (05) : 1672 - 1679
  • [6] CAPABILITIES OF RADPOS, 4D IN VIVO DOSIMETRY SYSTEM
    Cygler, J.
    Cherpak, A.
    Monica, S.
    Seuntjens, J.
    MacRae, R.
    Pantarotto, J.
    Perry, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S213 - S214
  • [7] Evaluation of a Novel 4D In-Vivo Dosimeter
    Cherpak, A.
    Hallil, A.
    Ding, W.
    Cygler, J.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [8] 4D TIME-RESOLVED IN-VIVO MICROTOMOGRAPHY
    Sasov, Alexander
    Liu, Xuan
    Salmon, Phil
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 582 - 585
  • [9] 3D In-vivo Dosimetry for Photon Radiotherapy Based on Pair Production
    Kormoll, Thomas
    Kunath, Daniela
    Enghardt, Wolfgang
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2969 - 2975
  • [10] Development of a patient specific quantitative 4D Dosimetry for internal radiotherapy
    Celler, A. M.
    Shcherbinin, S.
    Driedger, A.
    Belhocine, T.
    Vanderwerf, B.