Dual-energy x-ray absorptiometry: fat estimation errors due to variation in soft tissue hydration

被引:156
|
作者
Pietrobelli, A
Wang, ZM
Formica, C
Heymsfield, SB
机构
[1] Columbia Univ, St Lukes Roosevelt Hosp, Coll Phys & Surg, Obes Res Ctr, New York, NY 10025 USA
[2] Helen Hayes Hosp, Regional Bone Ctr, W Haverstraw, NY 10993 USA
关键词
body composition; physical model; fluid compartments;
D O I
10.1152/ajpendo.1998.274.5.E808
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-energy X-ray absorptiometry (DXA) is rapidly gaining acceptance as a reference method for analyzing body composition. An important and unresolved concern is whether and to what extent variation in soft tissue hydration causes errors in DXA fat estimates. The present study aim was to develop and validate a DXA physical hydration model, and then to apply this model by simulating errors arising from hypothetical overhydration states. The DXA physical hydration model was developed by first linking biological substance elemental content with photon attenuation. The validated physical model was next extended to describe photon attenuation changes anticipated when predefined amounts of two known composition components are mined, as would occur when overhydration develops. Two overhydration models were developed in the last phase of study, formulated on validated physical models, and error was simulated for fluid surfeit states. Results indicate that systematic errors in DXA percent fat arise with added fluids when fractional masses are varied as a percentage of combined fluid + soft tissue mass. Three independent determinants of error magnitude were established: elemental content of overhydration fluid, fraction of combined fluid + soft tissue as overhydration fluid, and initial soft tissue composition. Small but systematic and predictable errors in DXA soft tissue composition analysis thus: can arise with fluid balance changes.
引用
收藏
页码:E808 / E816
页数:9
相关论文
共 50 条
  • [41] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN NEUROMUSCULAR DISEASES
    KANDA, F
    FUJII, Y
    TAKAHASHI, K
    FUJITA, T
    [J]. MUSCLE & NERVE, 1994, 17 (04) : 431 - 435
  • [42] ERRORS DUE TO NONUNIFORM DISTRIBUTION OF FAT IN DUAL X-RAY ABSORPTIOMETRY OF THE LUMBAR SPINE
    TOTHILL, P
    PYE, DW
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (777): : 807 - 813
  • [43] Indications and reporting for dual-energy X-ray absorptiometry
    Leib, E
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (01) : 37 - 44
  • [44] LIMITATIONS OF DUAL-ENERGY X-RAY ABSORPTIOMETRY - REPLY
    ROUBENOFF, R
    KEHAYIAS, JJ
    DAWSONHUGHES, B
    HEYMSFIELD, SB
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (02): : 399 - 400
  • [45] Dual-energy X-ray absorptiometry and body composition
    Laskey, MA
    [J]. NUTRITION, 1996, 12 (01) : 45 - 51
  • [46] ENHANCED PRECISION WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    MAZESS, R
    CHESNUT, CH
    MCCLUNG, M
    GENANT, H
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (01) : 14 - 17
  • [47] The use of dual-energy x-ray absorptiometry in animals
    Grier, SJ
    Turner, AS
    Alvis, MR
    [J]. INVESTIGATIVE RADIOLOGY, 1996, 31 (01) : 50 - 62
  • [48] Dual-energy X-ray Absorptiometry Quality Matters
    Krueger, Diane
    Binkley, Neil
    Morgan, Sarah
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2018, 21 (02) : 155 - 156
  • [49] Dual-energy X-ray absorptiometry for body composition estimation in Chinese women
    He, M
    Li, ETS
    Kung, AWC
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1999, 53 (12) : 933 - 937
  • [50] Common errors in dual-energy X-ray absorptiometry scans in imaging centers in Ecuador
    Maldonado, Genessis
    Intriago, Maria
    Larroude, Maria
    Aguilar, Gabriel
    Moreno, Mario
    Gonzalez, Jose
    Vargas, Sara
    Vera, Claudia
    Rios, Karla
    Rios, Carlos
    [J]. ARCHIVES OF OSTEOPOROSIS, 2020, 15 (01)