Dual-energy X-ray absorptiometry (DXA) is rapidly gaining acceptance as a reference method for analyzing body composition. An important and unresolved concern is whether and to what extent variation in soft tissue hydration causes errors in DXA fat estimates. The present study aim was to develop and validate a DXA physical hydration model, and then to apply this model by simulating errors arising from hypothetical overhydration states. The DXA physical hydration model was developed by first linking biological substance elemental content with photon attenuation. The validated physical model was next extended to describe photon attenuation changes anticipated when predefined amounts of two known composition components are mined, as would occur when overhydration develops. Two overhydration models were developed in the last phase of study, formulated on validated physical models, and error was simulated for fluid surfeit states. Results indicate that systematic errors in DXA percent fat arise with added fluids when fractional masses are varied as a percentage of combined fluid + soft tissue mass. Three independent determinants of error magnitude were established: elemental content of overhydration fluid, fraction of combined fluid + soft tissue as overhydration fluid, and initial soft tissue composition. Small but systematic and predictable errors in DXA soft tissue composition analysis thus: can arise with fluid balance changes.
引用
收藏
页码:E808 / E816
页数:9
相关论文
共 50 条
  • [31] Measurement of soft tissue composition by dual energy X-ray absorptiometry
    Jebb, SA
    [J]. BRITISH JOURNAL OF NUTRITION, 1997, 77 (02) : 151 - 163
  • [32] Analysis Of Visceral Fat Tissue Via Dual-energy X-ray Absorptiometry And Magnetic Resonance Imaging
    Hyde, Parker N.
    Lamba, Nathan
    Crabtree, Christopher
    Scandling, Debbie
    Short, Jay A.
    LaFountain, Richard A.
    Sapper, Teryn N.
    Bowling, Madison L.
    Miller, Vincent J.
    Mc Swiney, Fionn T.
    Dickerson, Ryan M.
    Simonetti, Orlando P.
    Volek, Jeff S.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 484 - 485
  • [33] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [34] Accuracy of measurements of small changes in soft-tissue mass by dual-energy x-ray absorptiometry
    Lands, LC
    Hornby, L
    Hohenkerk, JM
    Glorieux, FH
    [J]. CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1996, 19 (04): : 279 - 285
  • [35] Dual-energy X-ray absorptiometry for body composition estimation in Chinese women
    M He
    ETS Li
    AWC Kung
    [J]. European Journal of Clinical Nutrition, 1999, 53 : 933 - 937
  • [36] SIMULATION STUDIES OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SORENSON, JA
    DUKE, PR
    SMITH, SW
    [J]. MEDICAL PHYSICS, 1989, 16 (01) : 75 - 80
  • [37] Dual-energy X-ray absorptiometry in early life
    Lapillonne, A
    Braillon, PM
    Delmas, PD
    Salle, BL
    [J]. HORMONE RESEARCH, 1997, 48 : 43 - 49
  • [38] Dual-energy X-ray absorptiometry scan: Guidelines
    Haymann, Jean-Philippe
    [J]. PROGRES EN UROLOGIE, 2010, 20 (04): : F119 - F122
  • [39] DUAL-ENERGY X-RAY ABSORPTIOMETRY - INTEREST IN ORTHOPEDICS
    MAUGARS, Y
    BERTHELOT, JM
    DELECRIN, J
    TRECANT, M
    PASSUTI, N
    DACULSI, G
    PROST, A
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1995, 81 (04): : 326 - 332
  • [40] Technical standardization for dual-energy X-ray absorptiometry
    Leib, E
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (01) : 27 - 36