Use of an Electronic Nose for Indoor Air Quality Monitoring

被引:16
|
作者
Sironi, Selena [1 ]
Eusebio, Lidia [1 ]
Capelli, Laura [1 ]
Remondini, Marco [2 ]
Del Rosso, Renato [1 ]
机构
[1] Politecn Milan, Dept Chem Mat & Chem Engn Giulio Natta, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[2] Sacmi sc, I-40026 Imola, Italy
关键词
VOLATILE ORGANIC-COMPOUNDS; SENSOR ARRAYS; RECOGNITION;
D O I
10.3303/CET1440013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor air quality is important to occupant health because it affects the health and comfort of occupants. Ventilation is the technique used for regulating indoor air quality. Currently, CO2 is the pollutant that is taken as the reference to calculate the makeup air rate and recirculation air rate of indoor spaces. Indeed, the quality of indoor air is affected by all microclimate components of the environment, concentration of odours and toxic materials, number of aerosols and microbes in the air, contamination by radioactive gases, static electricity etc. Regarding air quality, pleasant or unpleasant odours dominate the perception of the environment by the occupant and, among other pollutants that may be present in indoor environments, odour has been considered as one of the causes of different symptoms of the Sick Building Syndrome. This paper discusses the laboratory and indoor field tests conducted measuring both CO2 and odour in order to compare the concentration trends of these two parameters. The indoor air monitoring trial was conducted for a three month period in a university room used by students as a break room. Moreover, the performance of an innovative electronic nose, designed specifically for indoor applications (EOS 101), was evaluated. The tests prove the simplified electronic nose EOS 101 to be effective in the detection of odours in an indoor environment.
引用
收藏
页码:73 / +
页数:2
相关论文
共 50 条
  • [1] Analysis of indoor air quality using an electronic nose
    Schreiber, F
    Fitzner, K
    [J]. RECENT DEVELOPMENTS IN MEASUREMENT AND ASSESSMENT OF AIR POLLUTION, 1999, 1443 : 361 - 370
  • [2] Indoor Air Monitoring in Restaurant Using Portable Electronic Nose
    Pobkrut, Theerapat
    Siyang, Satetha
    Thepodum, Treenet
    Kerdcharoen, Teerakiat
    [J]. 2018 IEEE 7TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE 2018), 2018, : 451 - 452
  • [3] Electro-Optical Nose for Indoor Air Quality Monitoring
    Gonzalez, Victor
    Melendez, Felix
    Arroyo, Patricia
    Godoy, Javier
    Diaz, Fernando
    Suarez, Jose Ignacio
    Lozano, Jesus
    [J]. CHEMOSENSORS, 2023, 11 (10)
  • [4] Aerial Robot with Electronic Nose for Air Quality Monitoring
    Arroyo, Patricia
    Gomez-Suarez, Jaime
    Luis Herrero, Jose
    Lozano, Jesus
    [J]. ROBOT2022: FIFTH IBERIAN ROBOTICS CONFERENCE: ADVANCES IN ROBOTICS, VOL 2, 2023, 590 : 95 - 104
  • [5] Multi-purpose Connected Electronic Nose System for Health Screening and Indoor Air Quality Monitoring
    Choi, Jongwoo
    Park, Jun Seok
    Chang, SungJune
    Lee, Hae Ryong
    [J]. 2017 31ST INTERNATIONAL CONFERENCE ON INFORMATION NETWORKING (ICOIN), 2017, : 495 - 499
  • [6] Application of Electronic Nose Stations for Air Quality Monitoring in a Brewery
    Wai, Nandar Nyein
    Siyang, Satetha
    Pobkrut, Theerapat
    Thepudom, Treenet
    Kunarak, Chayanin
    Kerdcharoen, Teerakiat
    [J]. 2019 4TH IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - ASIA (IEEE ICCE-ASIA 2019), 2019, : 88 - 89
  • [7] A Wireless Electronic Nose for Emergency Indoor Monitoring
    Di Lecce, Vincenzo
    Daria, Rita
    Uva, Jessica
    [J]. PROCEEDINGS OF SENSORCOMM 2011, THE FIFTH INTERNATIONAL CONFERENCE ON SENSOR TECHNOLOGIES AND APPLICATIONS, 2011, : 274 - 279
  • [8] Air monitoring by means of electronic nose
    Kravchenko, Elena I.
    Petrov, Victor V.
    [J]. ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 864-867 : 908 - +
  • [9] An electronic nose based on solid state sensor arrays for low-cost indoor air quality monitoring applications
    Zampolli, S
    Elmi, I
    Ahmed, F
    Passini, M
    Cardinali, GC
    Nicoletti, S
    Dori, L
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (1-2) : 39 - 46
  • [10] Electronic cigarette use and indoor air quality in a natural setting
    Soule, Eric K.
    Maloney, Sarah F.
    Spindle, Tory R.
    Rudy, Alyssa K.
    Hiler, Marzena M.
    Cobb, Caroline O.
    [J]. TOBACCO CONTROL, 2017, 26 (01) : 109 - 112