Electro-Optical Nose for Indoor Air Quality Monitoring

被引:5
|
作者
Gonzalez, Victor [1 ]
Melendez, Felix [1 ]
Arroyo, Patricia [1 ]
Godoy, Javier [1 ]
Diaz, Fernando [1 ]
Suarez, Jose Ignacio [1 ]
Lozano, Jesus [1 ]
机构
[1] Univ Extremadura, Ind Engn Sch, Badajoz 06006, Spain
关键词
electronic nose; electro-optical nose; indoor air quality; metal oxide; non-dispersive infrared detector; PCA; PLS; CO2; CH4; VOCS; ELECTRONIC NOSE;
D O I
10.3390/chemosensors11100535
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays, indoor air pollution is a major problem that affects human health. For that reason, measuring indoor air quality has an increasing interest. Electronic noses are low-cost instruments (compared with reference methods) capable of measuring air components and pollutants at different concentrations. In this paper, an electro-optical nose (electronic nose that includes optical sensors) with non-dispersive infrared sensors and metal oxide semiconductor sensors is used to measure gases that affect indoor air quality. To validate the developed prototype, different gas mixtures (CH4 and CO2) with variable concentrations and humidity values are generated to confirm the discrimination capabilities of the device. Principal Component Analysis (PCA) was used for dimensionality reduction purposes to show the measurements in a plot. Partial Least Squares Regression (PLS) was also performed to calculate the predictive capabilities of the device. PCA results using all the measurements from all the sensors obtained PC1 = 47% and PC2 = 10%; results are improved using only the relevant information of the sensors obtaining PC1 = 79% and PC2 = 9%. PLS results with CH4 using only MOX sensors received an RMSE = 118.8. When using NDIR and MOX sensors, RMSE is reduced to 19.868; this tendency is also observed in CO2 (RMSE = 116.35 with MOX and RMSE = 20.548 with MOX and NDIR). The results confirm that the designed electro-optical nose can detect different gas concentrations and discriminate between different mixtures of gases; also, a better correlation and dispersion is achieved. The addition of NDIR sensors gives better results in measuring specific gases, discrimination, and concentration prediction capabilities in comparison to electronic noses with metal oxide gas sensors.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] An integrated electro-optical nose
    Tibuzzi, A
    Soncini, G
    D'Amico, A
    Di Natale, C
    Paolesse, R
    Macagnano, A
    Zen, A
    [J]. SENSORS AND MICROSYSTEMS, PROCEEDINGS, 2004, : 300 - 305
  • [2] Use of an Electronic Nose for Indoor Air Quality Monitoring
    Sironi, Selena
    Eusebio, Lidia
    Capelli, Laura
    Remondini, Marco
    Del Rosso, Renato
    [J]. NOSE2014: 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ODOUR MONITORING AND CONTROL, 2014, 40 : 73 - +
  • [3] Electro-Optical Monitoring of Human Cognitive Processes
    Vavrinsky, Erik
    Stopjakova, Viera
    Brezina, Igor
    Tvarozek, Vladimir
    Majer, Libor
    Solarikova, Petra
    [J]. ASDAM 2008, CONFERENCE PROCEEDINGS, 2008, : 279 - +
  • [4] Analysis of indoor air quality using an electronic nose
    Schreiber, F
    Fitzner, K
    [J]. RECENT DEVELOPMENTS IN MEASUREMENT AND ASSESSMENT OF AIR POLLUTION, 1999, 1443 : 361 - 370
  • [5] An Electro-Optical Approach for Monitoring the Fabrication of Slicon Nanopores
    Yang, Jianxin
    Ho, Aaron Ho-Pui
    [J]. 2022 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE, ACP, 2022, : 2060 - 2061
  • [6] Electro-optical modules for space monitoring of transportation systems
    Buchirin, VG
    Inozemtsev, VG
    Shilin, VA
    Karasev, VI
    Kolotkov, VV
    Kondratin, TV
    [J]. THIRD CONFERENCE ON PHOTONIC SYSTEMS FOR ECOLOGICAL MONITORING, 1997, 3200 : 19 - 22
  • [7] A high precise E-nose for daily indoor air quality monitoring in living environment
    He, Jie
    Xu, Liyuan
    Wang, Peng
    Wang, Qin
    [J]. INTEGRATION-THE VLSI JOURNAL, 2017, 58 : 286 - 294
  • [8] Indoor Air Monitoring in Restaurant Using Portable Electronic Nose
    Pobkrut, Theerapat
    Siyang, Satetha
    Thepodum, Treenet
    Kerdcharoen, Teerakiat
    [J]. 2018 IEEE 7TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE 2018), 2018, : 451 - 452
  • [9] Indoor Air Quality Monitoring Improving Air Quality Perception
    Herberger, Simone
    Ulmer, Heiko
    [J]. CLEAN-SOIL AIR WATER, 2012, 40 (06) : 578 - 585
  • [10] AN IMPROVED ELECTRO-OPTICAL IMAGE QUALITY SUMMARY MEASURE
    BLUMENTHAL, AH