Use of an Electronic Nose for Indoor Air Quality Monitoring

被引:16
|
作者
Sironi, Selena [1 ]
Eusebio, Lidia [1 ]
Capelli, Laura [1 ]
Remondini, Marco [2 ]
Del Rosso, Renato [1 ]
机构
[1] Politecn Milan, Dept Chem Mat & Chem Engn Giulio Natta, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[2] Sacmi sc, I-40026 Imola, Italy
关键词
VOLATILE ORGANIC-COMPOUNDS; SENSOR ARRAYS; RECOGNITION;
D O I
10.3303/CET1440013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor air quality is important to occupant health because it affects the health and comfort of occupants. Ventilation is the technique used for regulating indoor air quality. Currently, CO2 is the pollutant that is taken as the reference to calculate the makeup air rate and recirculation air rate of indoor spaces. Indeed, the quality of indoor air is affected by all microclimate components of the environment, concentration of odours and toxic materials, number of aerosols and microbes in the air, contamination by radioactive gases, static electricity etc. Regarding air quality, pleasant or unpleasant odours dominate the perception of the environment by the occupant and, among other pollutants that may be present in indoor environments, odour has been considered as one of the causes of different symptoms of the Sick Building Syndrome. This paper discusses the laboratory and indoor field tests conducted measuring both CO2 and odour in order to compare the concentration trends of these two parameters. The indoor air monitoring trial was conducted for a three month period in a university room used by students as a break room. Moreover, the performance of an innovative electronic nose, designed specifically for indoor applications (EOS 101), was evaluated. The tests prove the simplified electronic nose EOS 101 to be effective in the detection of odours in an indoor environment.
引用
收藏
页码:73 / +
页数:2
相关论文
共 50 条
  • [21] Polymer-carbon black composite sensors in an electronic nose for air-quality monitoring
    Ryan, MA
    Shevade, AV
    Zhou, H
    Homer, ML
    [J]. MRS BULLETIN, 2004, 29 (10) : 714 - 719
  • [22] Development of mobile electronic nose for beef quality monitoring
    Wijaya, Dedy Rahman
    Sarno, Riyanarto
    Zulaika, Enny
    Sabila, Shoffi Izza
    [J]. 4TH INFORMATION SYSTEMS INTERNATIONAL CONFERENCE (ISICO 2017), 2017, 124 : 728 - 735
  • [23] An electronic nose system for monitoring the quality of potable water
    Gardner, JW
    Shin, HW
    Hines, EL
    Dow, CS
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) : 336 - 341
  • [24] Indoor air quality monitoring universal device
    Panaitescu, M.
    Dumitrescu, M., V
    Panaitescu, F., V
    [J]. MODTECH INTERNATIONAL CONFERENCE - MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING VIII, 2020, 916
  • [25] Health Informatics for Indoor Air Quality Monitoring
    Marques, Goncalo
    Pitarma, Rui
    [J]. 2016 11TH IBERIAN CONFERENCE ON INFORMATION SYSTEMS AND TECHNOLOGIES (CISTI), 2016,
  • [26] A wireless system for indoor air quality monitoring
    du Plessis, R.
    Kumar, A.
    Hancke, G. P.
    Silva, B. J.
    [J]. PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 5409 - 5414
  • [27] Monitoring indoor air quality in the Czech Republic
    Drahonovska, H
    Gajdos, P
    [J]. INDOOR AND BUILT ENVIRONMENT, 1997, 6 (04) : 198 - 203
  • [28] A Movable Indoor Air Quality Monitoring System
    Liu Peng
    Fu Danni
    Jiang Shengqian
    Wang Mingjie
    [J]. 2017 2ND INTERNATIONAL CONFERENCE ON CYBERNETICS, ROBOTICS AND CONTROL (CRC 2017), 2017, : 126 - 129
  • [29] Monitoring of biofiltration efficiency of bioreactor exhaust air by an electronic nose
    Martinelli, E
    Pennazza, G
    Paolesse, R
    Miliàn, E
    Albiol, J
    Godìa, F
    Van Ras, N
    Van der Waarde, J
    Demey, D
    Di Natale, C
    D'Amico, A
    [J]. PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 368 - 371
  • [30] An E-Nose-based indoor air quality monitoring system: prediction of combustible and toxic gas concentrations
    Mumyakmaz, Bekir
    Karabacak, Kerim
    [J]. TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2015, 23 (03) : 729 - 740