Seismic Reassessment of the Leaning Tower of Pisa: Dynamic Monitoring, Site Response, and SSI

被引:9
|
作者
Fiorentino, Gabriele [1 ]
Quaranta, Giuseppe [2 ]
Mylonakis, George [3 ,4 ,5 ]
lavorato, Davide [1 ]
Pagliaroli, Alessandro [6 ]
Carlucci, Giorgia [7 ]
Sabetta, Fabio [8 ]
Della Monica, Giuseppe [7 ]
Lanzo, Giuseppe [2 ]
Aprile, Victoria [6 ]
Marano, Giuseppe Carlo [6 ,8 ,9 ]
Briseghella, Bruno [8 ]
Monti, Giorgio [2 ,10 ]
Squeglia, Nunziante [11 ]
Bartelletti, Raffaello [11 ]
Nuti, Camillo [1 ,2 ]
机构
[1] Roma Tre Univ, Dept Architecture, Rome, Italy
[2] Sapienza Univ Rome, Dept Struct & Geotech Engn, Rome, Italy
[3] Univ Bristol, Dept Civil Engn, Bristol, Avon, England
[4] Univ Patras, Dept Civil Engn, Patras, Greece
[5] Univ Calif Los Angeles, Dept Civil & Environm Engn, Los Angeles, CA USA
[6] Univ G dAnnunzio, Dept Engn & Geol, Pescara, Italy
[7] Roma Tre Univ, Dept Sci, Rome, Italy
[8] Fuzhou Univ, Coll Civil Engn, Fuzhou, Fujian, Peoples R China
[9] Tech Univ Bari, Dept Sci Civil Engn & Architecture, Bari, Italy
[10] Nanjing Tech Univ, Coll Civil Engn, Nanjing, Jiangsu, Peoples R China
[11] Univ Pisa, Dept Civil & Ind Engn, Pisa, Italy
关键词
SOIL-STRUCTURE INTERACTION; GROUND-MOTION; SYSTEM-IDENTIFICATION; HAZARD; BUILDINGS; ALGORITHM; PREDICTION; INVERSION; FOOTINGS; MODEL;
D O I
10.1193/021518EQS037M
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Tower of Pisa survived several strong earthquakes undamaged over the last 650 years, despite its leaning and limited strength and ductility. No credible explanation for its remarkable seismic performance exists to date. A reassessment of this unique case history in light of new seismological, geological, structural, and geotechnical information is reported, aiming to address this question. The following topics are discussed: (1) dynamic structural identification based on recorded earthquake data; (2) geophysical site characterization using a two-dimensional array; (3) seismic hazard and site response analysis considering horizontal and vertical motions; and (4) soil-structure interaction (SSI) analysis calibrated using lab and field data. A substantial shift in natural period, from about 0.35 s to over 1 s (a threefold increase, the largest known for a building of that height) caused by SSI, a wave parameter (1/sigma) of about 0.3, and a minor effect of vertical ground motion are identified and may explain the lack of earthquake damage on the Tower. Recommendations for future research, including the need to establish a seismic bedrock deeper than 500 m, are provided.
引用
收藏
页码:703 / 736
页数:34
相关论文
共 50 条
  • [1] Role of Monitoring in Historical Building Restoration: The Case of Leaning Tower of Pisa
    Squeglia, Nunziante
    Bentivoglio, Giuseppe
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2014, 9 (01) : 38 - 47
  • [2] Analysis of Dynamic Property and Seismic Response on Leaning Arch Bridge
    Wu, Zeyu
    Wang, Fuming
    Wang, Dongwei
    [J]. 2010 INTERNATIONAL CONFERENCE ON ENGINEERING COMPUTATION (ICEC 2010), 2010, : 145 - 148
  • [3] One-Dimensional Nonlinear Seismic Response Analysis Using Strength-Controlled Constitutive Models: The Case of the Leaning Tower of Pisa's Subsoil
    Fiorentino, Gabriele
    Nuti, Camillo
    Squeglia, Nunziante
    Lavorato, Davide
    Stacul, Stefano
    [J]. GEOSCIENCES, 2018, 8 (07)
  • [4] Nonlinear interaction of initial leaning of r/c slender tower with its seismic response
    Bonkowski, P.
    Zembaty, Z.
    Minch, M. Y.
    [J]. INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 303 - 308
  • [5] Dynamic and seismic health monitoring of a historic masonry tower
    Saisi, Antonella
    Gentile, Carmelo
    Guidobaldi, Marco
    [J]. Ingegneria Sismica, 2014, 31 (03):
  • [6] Dynamic and Seismic Health Monitoring of a Historic Masonry Tower
    Saisi, Antonella
    Gentile, Carmelo
    Guidobaldi, Marco
    [J]. INGEGNERIA SISMICA, 2014, 31 (3-4): : 45 - 58
  • [7] Dynamic characteristics and seismic response of rectangular aqueduct with baffle considering SSI effect
    Ying, Lei
    Zhou, Ding
    Wang, Jue
    Fang, Zhong-Jie
    Zhou, Wen-Ling
    [J]. Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2017, 30 (06): : 1001 - 1011
  • [8] Structural Dynamic Response Monitoring of Power Transmission Tower
    Xia, Kaiquan
    Liu, Xuewu
    Liu, Yun
    [J]. VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT I, PTS 1-3, 2012, 105-107 : 986 - +
  • [9] Seismic response and dynamic characteristic analysis of the complex intake tower structure
    Ma, Chenggang
    Lai, Yongxing
    Liu, Minshan
    [J]. INTEGRATED APPROACHES FOR MATERIALS AND STRUCTURAL SAFETY, 2007, : 229 - 237
  • [10] Dynamic Response of Tower Cranes Under Seismic Actions. Case Study
    Alamoreanu, Mircea
    Vasilescu, Andrei
    [J]. ROMANIAN JOURNAL OF ACOUSTICS AND VIBRATION, 2011, 8 (02): : 85 - 90