Structural Dynamic Response Monitoring of Power Transmission Tower

被引:0
|
作者
Xia, Kaiquan [1 ]
Liu, Xuewu [1 ]
Liu, Yun [2 ]
机构
[1] China Elect Power Res Inst, Beijing 100055, Peoples R China
[2] Hohai Univ, Nanjing 210098, Jiangsu, Peoples R China
关键词
Transmission Line; Steel Tower; Structural Dynamics Response; Real-Time Monitoring;
D O I
10.4028/www.scientific.net/AMM.105-107.986
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to study the dynamic response of power transmission lines under mechanical fault, the structural dynamic response monitoring indexes based on the requirement of field measurement were determined according to the structural characteristics of steel towers. The monitoring program was put forward in terms of the monitoring principle and basis of the sensors. The vibration characteristic, dynamic alignment and stress/strain are chosen to be the monitoring indexes. Considering the synchronization function of GPS system, the three monitoring indexes of the large span high voltage tower can be simultaneously monitored by using vibration sensor, GPS and strain sensor. The monitoring scheme can provide the theoretical base for the establishment of early warning system and the collection of dynamic response of steel tower during line break or tower collapse.
引用
收藏
页码:986 / +
页数:2
相关论文
共 50 条
  • [1] DYNAMIC STRUCTURAL HEALTH MONITORING OF A TRANSMISSION TOWER USING INTERFEROMETRIC RADAR
    Paiva, Fabio
    de Barros, Rui Carneiro
    Guerreiro, Luis
    [J]. IRF2018: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON INTEGRITY-RELIABILITY-FAILURE, 2018, : 1301 - 1302
  • [2] Wind-induced dynamic response analysis for power transmission tower by PDEM
    Zhang, LL
    Li, J
    [J]. TALL BUILDINGS: FROM ENGINEERING TO SUSTAINABILITY, 2005, : 462 - 467
  • [3] Wind-induced dynamic response of transmission tower
    Sun, BN
    Lou, WJ
    Tang, JC
    [J]. WIND ENGINEERING INTO THE 21ST CENTURY, VOLS 1-3, 1999, : 577 - 582
  • [4] Monitoring the structural dynamic response of a masonry tower: comparing classical and time-frequency analyses
    Rocco Ditommaso
    Marco Mucciarelli
    Stefano Parolai
    Matteo Picozzi
    [J]. Bulletin of Earthquake Engineering, 2012, 10 : 1221 - 1235
  • [5] Monitoring the structural dynamic response of a masonry tower: comparing classical and time-frequency analyses
    Ditommaso, Rocco
    Mucciarelli, Marco
    Parolai, Stefano
    Picozzi, Matteo
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2012, 10 (04) : 1221 - 1235
  • [6] Dynamic Analysis of Power Transmission Tower Collapse with Wind Load
    Wang, Liang
    Qu, Weilian
    Li, Yanfei
    Wang, Yifei
    [J]. CIVIL, STRUCTURAL AND ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 838-841 : 494 - +
  • [7] Structural Response of a Large Transmission Tower to a Tornado in East China
    Zhang, Nai-Long
    Qiu, Gang
    Tan, Xiao
    Chen, Jie
    Sun, Rong
    Wu, Bai-Jian
    Cheng, Xiao-Xiang
    [J]. SHOCK AND VIBRATION, 2024, 2024
  • [8] Dynamic Response Analysis of Transmission Tower under Thunderstorm Downburst
    Jin, Y. J.
    Xu, Y. L.
    Xia, Y.
    Qu, W. L.
    [J]. DYNAMICS FOR SUSTAINABLE ENGINEERING, VOL 2, 2011, : 556 - 563
  • [9] Structural health monitoring of transmission tower based on inclinometer sensing system
    Ma, Jun
    Lu, Bo
    Zhang, Tianming
    Zhang, Liang
    Zhao, Xuefeng
    [J]. HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS XV, 2021, 11593
  • [10] Structural health monitoring oriented stability and dynamic analysis of a long-span transmission tower-line system
    Fei, Qingguo
    Zhou, Honggang
    Han, Xiaolin
    Wang, Jiang
    [J]. ENGINEERING FAILURE ANALYSIS, 2012, 20 : 80 - 87