Vascular complications of liver transplantation: Evaluation with gadolinium-enhanced MR angiography

被引:71
|
作者
Stafford-Johnson, DB
Hamilton, BH
Dong, Q
Cho, KJ
Turcotte, JG
Fontana, RJ
Prince, MR
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Med Ctr, Dept Transplant Surg, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Med Ctr, Dept Gastroenterol, Ann Arbor, MI 48109 USA
关键词
gadolinium; liver; transplantation; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.207.1.9530311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate use of gadolinium-enhanced magnetic resonance (MR) angiography in detection of vascular complications of liver transplantation. MATERIALS AND METHODS: Thirteen liver transplant recipients suspected to have vascular complications were evaluated with gadolinium-enhanced MR angiography by using a three-dimensional spoiled gradient-echo breath-hold technique during the arterial and venous phases of;a high-dose (42 mt) bolus injection of gadolinium contrast material. Conventional angiography (n = 11) and surgery (n = 3) were used as the standard of reference. The transplant hepatic artery, celiac trunk, superior mesenteric artery, portal vein, superior mesenteric Vein, splenic vein. hepatic veins, and inferior vena cava (IVC) were evaluated for thrombosis or stenosis is by two radiologists. RESULTS: Ten vascular complications were identified with conventional angiography or surgery: transplant hepatic artery thrombosis (n = 3) or stenosis (n = 3), portal vein stenosis (n = 1) or occlusion (n = 2), and suprahepatic IVC stenosis n = 1, All 10 complications were correctly diagnosed with MR angiography. There was agreement between results of MR angiography and conventional angiography or surgery In 58 of 62 vessels evaluated (94%). There was minor disagreement in four vessels (6%). CONCLUSION: Three-dimensional gadolinium-enhanced MR angiography may have the potential to enable accurate diagnosis of Vascular Complications of liver transplantation.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [31] Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta
    Prince, MR
    Narasimham, DL
    Jacoby, WT
    Williams, DM
    Cho, KJ
    Marx, MV
    Deeb, GM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) : 1387 - 1397
  • [32] Review of source images is necessary for the evaluation of gadolinium-enhanced MR angiography for renal artery stenosis
    Wehrschuetz, M
    Aschauer, M
    Portugaller, H
    Stix, A
    Wehrschuetz-Sigl, E
    Hausegger, K
    Ebner, F
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 27 (05) : 441 - 446
  • [33] Review of Source Images is Necessary for the Evaluation of Gadolinium-Enhanced MR Angiography for Renal Artery Stenosis
    M. Wehrschuetz
    M. Aschauer
    H. Portugaller
    A. Stix
    E. Wehrschuetz-Sigl
    K. Hausegger
    F. Ebner
    CardioVascular and Interventional Radiology, 2004, 27 : 441 - 446
  • [34] Cardiac-synchronized gadolinium-enhanced MR angiography: preliminary experience for the evaluation of the thoracic aorta
    Goldfarb, JW
    Holland, AE
    Heijstraten, FMJ
    Skotnicki, S
    Barentsz, JO
    MAGNETIC RESONANCE IMAGING, 2006, 24 (03) : 241 - 248
  • [35] Gadolinium-enhanced three-dimensional MR angiography of Takayasu arteritis
    Nastri, MV
    Baptista, LPS
    Baroni, RH
    Blasbalg, R
    de Avila, LF
    Leite, CC
    de Castro, CC
    Cerri, GG
    RADIOGRAPHICS, 2004, 24 (03) : 773 - 786
  • [36] GADOLINIUM-ENHANCED MAGNITUDE CONTRAST MR ANGIOGRAPHY OF POPLITEAL AND TIBIAL ARTERIES
    LOSSEF, SV
    RAJAN, SS
    PATT, RH
    CARVLIN, M
    CALCAGNO, D
    GOMES, MN
    BARTH, KH
    RADIOLOGY, 1992, 184 (02) : 349 - 355
  • [37] 3D gadolinium-enhanced MR angiography of the carotid arteries
    Cloft, HJ
    Murphy, KJ
    Prince, MR
    Brunberg, JA
    MAGNETIC RESONANCE IMAGING, 1996, 14 (06) : 593 - 600
  • [38] Determination of optimal injection parameters for intraarterial gadolinium-enhanced MR angiography
    Frayne, R
    Omary, RA
    Unal, O
    Strother, CM
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (10) : 1277 - 1284
  • [39] Gadolinium-enhanced MR angiography for the evaluation of inferior vena caval tumor thrombus in renal carcinoma
    Kato, K
    Togami, I
    Sasai, N
    Hiraki, Y
    RADIOLOGY, 1996, 201 : 177 - 177
  • [40] Contrast-enhanced MR angiography (CE-MRA) in the evaluation of vascular complications of renal transplantation
    Jain, R
    Sawhney, S
    CLINICAL RADIOLOGY, 2005, 60 (11) : 1171 - 1181