Vascular complications of liver transplantation: Evaluation with gadolinium-enhanced MR angiography

被引:71
|
作者
Stafford-Johnson, DB
Hamilton, BH
Dong, Q
Cho, KJ
Turcotte, JG
Fontana, RJ
Prince, MR
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Med Ctr, Dept Transplant Surg, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Med Ctr, Dept Gastroenterol, Ann Arbor, MI 48109 USA
关键词
gadolinium; liver; transplantation; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.207.1.9530311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate use of gadolinium-enhanced magnetic resonance (MR) angiography in detection of vascular complications of liver transplantation. MATERIALS AND METHODS: Thirteen liver transplant recipients suspected to have vascular complications were evaluated with gadolinium-enhanced MR angiography by using a three-dimensional spoiled gradient-echo breath-hold technique during the arterial and venous phases of;a high-dose (42 mt) bolus injection of gadolinium contrast material. Conventional angiography (n = 11) and surgery (n = 3) were used as the standard of reference. The transplant hepatic artery, celiac trunk, superior mesenteric artery, portal vein, superior mesenteric Vein, splenic vein. hepatic veins, and inferior vena cava (IVC) were evaluated for thrombosis or stenosis is by two radiologists. RESULTS: Ten vascular complications were identified with conventional angiography or surgery: transplant hepatic artery thrombosis (n = 3) or stenosis (n = 3), portal vein stenosis (n = 1) or occlusion (n = 2), and suprahepatic IVC stenosis n = 1, All 10 complications were correctly diagnosed with MR angiography. There was agreement between results of MR angiography and conventional angiography or surgery In 58 of 62 vessels evaluated (94%). There was minor disagreement in four vessels (6%). CONCLUSION: Three-dimensional gadolinium-enhanced MR angiography may have the potential to enable accurate diagnosis of Vascular Complications of liver transplantation.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [21] Noninvasive imaging of living related kidney donors: Evaluation with CT angiography and gadolinium-enhanced MR angiography
    Rankin, SC
    Jan, W
    Koffman, CG
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) : 349 - 355
  • [22] Classification of cirrhotic liver in Gadolinium-enhanced MR images
    Lee, Gobert
    Uchiyama, Yoshikazu
    Zhang, Xuejun
    Kanematsu, Masayuki
    Zhou, Xiangrong
    Hara, Takeshi
    Kato, Hiroki
    Kondo, Hiroshi
    Fijita, Hiroshi
    Hoshi, Hiroaki
    MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2007, 6514
  • [23] Gadolinium-enhanced CT angiography
    Karcaaltincaba, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) : 1083 - 1083
  • [24] Gadolinium-enhanced three-dimensional MR angiography with MR Smart Prep
    Isogai, S
    Takehara, Y
    Isoda, H
    Kodaira, N
    Furutani, K
    Kaneko, M
    RADIOLOGY, 1997, 205 : 1240 - 1240
  • [25] Superior diagnostic strength of gadolinium-enhanced MR angiography compared to intra-arterial DSA in orthotopic liver transplantation candidates
    Boeve, WJ
    Haagsma, EB
    Kok, T
    Slooff, MJ
    Kamman, RL
    RADIOLOGY, 1999, 213P : 438 - 438
  • [26] GADOLINIUM-ENHANCED MR AORTOGRAPHY
    PRINCE, MR
    RADIOLOGY, 1994, 191 (01) : 155 - 164
  • [27] GADOLINIUM-ENHANCED MR IN THE EVALUATION OF PREOPERATIVE MENINGIOMA EMBOLIZATION
    GRAND, C
    BANK, WO
    BALERIAUX, D
    MATOS, C
    DEWITTE, O
    BROTCHI, J
    DELCOUR, C
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (03) : 563 - 569
  • [28] Evaluation of Clinically Significant Renal Artery Stenosis with Gadolinium-Enhanced MR Angiography: Comparison with Digital Subtraction Angiography
    Law, Y.
    Tay, K.
    Gan, Y.
    Cheah, F.
    Tan, B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [29] Gadolinium-enhanced three-dimensional MR angiography of the thoracoabdominal aorta
    Krinsky, G
    Weinreb, J
    SEMINARS IN ULTRASOUND CT AND MRI, 1996, 17 (04) : 280 - 303
  • [30] Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography
    Davis, CP
    Hany, TF
    Wildermuth, S
    Schmidt, M
    Debatin, JF
    RADIOGRAPHICS, 1997, 17 (05) : 1061 - 1077