3D echocardiography pre-processing for ventricular volume estimation

被引:1
|
作者
Brancaleoni, F [1 ]
Mikula, K [1 ]
Sarti, A [1 ]
Lamberti, C [1 ]
机构
[1] Univ Bologna, DEIS, I-40136 Bologna, Italy
来源
关键词
D O I
10.1109/CIC.1997.647893
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A method for left ventricular volume estimation based on 3D Echographic data is presented Pre-preocessing of 3D data is performed by means of two different non linear diffusion techniques: anisotropic diffusion and geometrical diffusion (mean curvature motion). Anisotropic diffusion, which assumes a high diffusion velocity, in region with low brigthness gradient and vice-versa, produces a filterig effect without smoothing the edges. On the contrary, geometrical diffusion, which assumes a diffusion velocity according to local curvature, produces a smoothing of surfaces. The ventricular volume is estimated through a flood-fill operation and divergence theorem.
引用
收藏
页码:311 / 314
页数:4
相关论文
共 50 条
  • [21] Pre-Processing of Point-Data from Contact and Optical 3D Digitization Sensors
    Budak, Igor
    Vukelic, Djordje
    Bracun, Drago
    Hodolic, Janko
    Sokovic, Mirko
    [J]. SENSORS, 2012, 12 (01) : 1100 - 1126
  • [22] A combined pre-processing and H.264-compression scheme for 3D integral images
    Olsson, Roger
    Sjostrom, Marten
    Xu, Youzhi
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 513 - +
  • [23] Evaluation of right ventricular volume and function by 2D and 3D echocardiography compared to MRI
    Kjaergaard, Jesper
    Petersen, Claus Leth
    Kjaer, Andreas
    Schaadt, Bente Krogsgaard
    Oh, Jae K.
    Hassager, Christian
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (06): : 430 - 438
  • [24] Assessment of fetal ventricular volume by dynamic 3D/4D echocardiography in normal fetuses
    Hui, L
    Sahn, CS
    Niemann, PS
    Wyatt, S
    Sahn, DJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 243A - 243A
  • [25] 3D Breast Volume Estimation
    Gouveia, Pedro F.
    Oliveira, Helder P.
    Monteiro, Joao P.
    Teixeira, Joao F.
    Silva, Nuno L.
    Pinto, David
    Mavioso, Carlos
    Anacleto, Joao
    Martinho, Marta
    Duarte, Ines
    Cardoso, Jaime S.
    Cardoso, Fatima
    Cardoso, Maria Joao
    [J]. EUROPEAN SURGICAL RESEARCH, 2022, 63 (01) : 3 - 8
  • [26] A closer look at right ventricular 3D volume quantification by transthoracic echocardiography and cardiac MRI
    Greiner, S.
    Andre, F.
    Heimisch, M.
    Aurich, M.
    Steen, H.
    Katus, H. A.
    Mereles, D.
    [J]. CLINICAL RADIOLOGY, 2019, 74 (06) : 490.e7 - 490.e14
  • [27] Preliminary analysis of thorax CT image pre-processing and 3D modeling of patients with pectus excavatum
    Tang, Bo
    Jiang, Li
    [J]. ADVANCED RESEARCH ON INDUSTRY, INFORMATION SYSTEM AND MATERIAL ENGINEERING, 2012, 459 : 465 - +
  • [28] Evaluation of a combined pre-processing and H.264-compression scheme for 3D integral images
    Olsson, Roger
    Sjostrom, Marten
    Xu, Youzhi
    [J]. VISUAL COMMUNICATIONS AND IMAGE PROCESSING 2007, PTS 1 AND 2, 2007, 6508
  • [29] Fast motion estimation from pre-processing algorithm
    Hu, Zhao-Zheng
    Li, Na
    Tan, Zheng
    [J]. Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2006, 38 (10): : 1709 - 1711
  • [30] 3D fusion echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography
    Augustine, D.
    Yaqub, M.
    Szmigielski, C.
    Lima, E.
    Neubauer, S.
    Petersen, S. E.
    Becher, H.
    Noble, A.
    Leeson, P.
    [J]. EUROPEAN HEART JOURNAL, 2013, 34 : 1100 - 1100