3D Breast Volume Estimation

被引:8
|
作者
Gouveia, Pedro F. [1 ,2 ]
Oliveira, Helder P. [3 ,4 ]
Monteiro, Joao P. [3 ]
Teixeira, Joao F. [3 ]
Silva, Nuno L. [5 ]
Pinto, David [1 ,5 ]
Mavioso, Carlos [1 ]
Anacleto, Joao [1 ]
Martinho, Marta [1 ]
Duarte, Ines [6 ]
Cardoso, Jaime S. [3 ,7 ]
Cardoso, Fatima [1 ]
Cardoso, Maria Joao [1 ,5 ]
机构
[1] Champalimaud Fdn, Breast Unit, Champalimaud Clin Ctr, Lisbon, Portugal
[2] Lisbon Univ, Fac Med, Lisbon, Portugal
[3] INESCTEC, Porto, Portugal
[4] Univ Porto, Fac Sci, Porto, Portugal
[5] NOVA Med Sch, Lisbon, Portugal
[6] Inst Super Tecn, Lisbon, Portugal
[7] Univ Porto, Fac Engn, Porto, Portugal
关键词
Breast cancer; Breast volume; 3D surface scan; Breast MRI; Experimental study; Surgery; CANCER SURGERY; CLASSIFICATION;
D O I
10.1159/000516357
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Breast volume estimation is considered crucial for breast cancer surgery planning. A single, easy, and reproducible method to estimate breast volume is not available. This study aims to evaluate, in patients proposed for mastectomy, the accuracy of the calculation of breast volume from a low-cost 3D surface scan (Microsoft Kinect) compared to the breast MRI and water displacement technique. Material and Methods: Patients with a Tis/T1-T3 breast cancer proposed for mastectomy between July 2015 and March 2017 were assessed for inclusion in the study. Breast volume calculations were performed using a 3D surface scan and the breast MRI and water displacement technique. Agreement between volumes obtained with both methods was assessed with the Spearman and Pearson correlation coefficients. Results: Eighteen patients with invasive breast cancer were included in the study and submitted to mastectomy. The level of agreement of the 3D breast volume compared to surgical specimens and breast MRI volumes was evaluated. For mastectomy specimen volume, an average (standard deviation) of 0.823 (0.027) and 0.875 (0.026) was obtained for the Pearson and Spearman correlations, respectively. With respect to MRI annotation, we obtained 0.828 (0.038) and 0.715 (0.018). Discussion: Although values obtained by both methodologies still differ, the strong linear correlation coefficient suggests that 3D breast volume measurement using a low-cost surface scan device is feasible and can approximate both the MRI breast volume and mastectomy specimen with sufficient accuracy. Conclusion: 3D breast volume measurement using a depth-sensor low-cost surface scan device is feasible and can parallel MRI breast and mastectomy specimen volumes with enough accuracy. Differences between methods need further development to reach clinical applicability. A possible approach could be the fusion of breast MRI and the 3D surface scan to harmonize anatomic limits and improve volume delimitation.
引用
收藏
页码:3 / 8
页数:6
相关论文
共 50 条
  • [1] Segmentation-free estimation of volume changes in 3D ultrasound of breast lesion phantoms
    Narayanasamy, Ganesh
    Narayanan, R.
    Fowlkes, J. Brian
    Roubidoux, Marilyn
    Carson, Paul L.
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [2] 3D Reconstruction Methods Purporting 3D Visualization and Volume Estimation of Brain Tumors
    Joseph, Sushitha Susan
    Aju, D.
    [J]. INTERNATIONAL JOURNAL OF E-COLLABORATION, 2022, 18 (01)
  • [3] Object Volume Estimation Based on 3D Point Cloud
    Chang, Wen-Chung
    Wu, Chia-Hung
    Tsai, Ya-Hui
    Chiu, Wei-Yao
    [J]. 2017 INTERNATIONAL AUTOMATIC CONTROL CONFERENCE (CACS), 2017,
  • [4] Volume Estimation of Pathology Zones in 3D Medical Images
    Krechetova, K.
    Glazs, A.
    [J]. 4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 617 - 620
  • [5] Current status of 3D/4D volume ultrasound of the breast
    Weismann, C.
    Hergan, K.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2007, 28 (03): : 273 - 282
  • [6] Breast volume estimation from systematic series of CT scans using the Cavalieri principle and 3D reconstruction
    Eric, Mirela
    Anderla, Andras
    Stefanovic, Darko
    Drapsin, Miodrag
    [J]. INTERNATIONAL JOURNAL OF SURGERY, 2014, 12 (09) : 912 - 917
  • [7] Left ventricle volume estimation from 3D SPECT reconstruction
    Garcia-Panyella, O
    Susin, A
    [J]. COMPUTERS IN CARDIOLOGY 2002, VOL 29, 2002, 29 : 621 - 624
  • [8] 3D echocardiography pre-processing for ventricular volume estimation
    Brancaleoni, F
    Mikula, K
    Sarti, A
    Lamberti, C
    [J]. COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 311 - 314
  • [9] Estimation of 3D Sphericity by Volume Measurement - Application to Coarse Aggregates
    Bhattacharya, Sumana
    Subedi, Sudip
    Lee, Seung Jae
    Pradhananga, Nipesh
    [J]. TRANSPORTATION GEOTECHNICS, 2020, 23
  • [10] 3D Medical Image Visualization and Volume Estimation of Pathology Zones
    Krechetova, K.
    Glaz, A.
    Platkajis, A.
    [J]. 14TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS, 2008, 20 : 532 - +