Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method

被引:27
|
作者
Butson, MJ
Elferink, R
Cheung, T
Yu, PKN
Stokes, M
Quach, KY
Metcalfe, P
机构
[1] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
[2] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon Tong, Hong Kong, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2000年 / 45卷 / 11期
关键词
D O I
10.1088/0031-9155/45/11/402
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Verification of calculated lung dose in an anthropomorphic phantom is performed using two dosimetry media. Dosimetry is complicated by factors such as variations in density at slice interfaces and appropriate position on CT scanning slice to accommodate these factors. Dose in lung for a 6 MV and 10 MV anterior-posterior field was calculated with a collapsed cone convolution method using an ADAC Pinnacle, 3D planning system. Up to 5% variations between doses calculated at the centre and near the edge of the 2 cm phantom slice positioned at the beam central axis were seen, due to the composition of each phantom slice. Validation of dose was performed with LiF thermoluminescent dosimeters (TLDs) and X-Omat V radiographic film. Both dosimetry media produced dose results which agreed closely with calculated results nearest their physical positioning in the phantom. The collapsed cone convolution method accurately calculates dose within inhomogeneous lung regions at 6 MV and 10 MV x-ray energy.
引用
收藏
页码:N143 / N149
页数:7
相关论文
共 50 条
  • [21] A collapsed-cone convolution/superposition dose computation algorithm for sliding window beams
    Moreau, M
    Gibbons, J
    Bzdusek, K
    McNutt, T
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2161 - 2161
  • [22] Technical Note: Experimental verification of EGSnrc calculated depth dose within a parallel magnetic field in a lung phantom
    Ghila, Andrei
    Fallone, B. Gino
    Rathee, Satyapal
    [J]. MEDICAL PHYSICS, 2018, 45 (12) : 5653 - 5658
  • [23] Portal dose image verification:: the collapsed cone superposition method applied with different electronic portal imaging devices
    Dahlgren, CV
    Eilertsen, K
    Jorgensen, TD
    Ahnesjö, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02): : 335 - 349
  • [24] Dosimetric Evaluation of Collapsed Cone Convolution (CCC) Algorithm in Predicting Dose Beyond Air Gap
    Oyewale, S.
    Rana, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [25] Acuros(R)dose verification of ultrasmall lung lesions with EBT-XD film in a homogeneous and heterogeneous anthropomorphic phantom setup
    Ollers, Michel C.
    Swinnen, Ans C. C.
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2020, 47 (11) : 5829 - 5837
  • [26] Precise dosimetric comparison between GAMOS and the collapsed cone convolution algorithm of 4D DOSE accumulated in lung SBRT treatments
    Arce, Pedro
    Lagares, Juan Ignacio
    Azcona, Juan Diego
    Huesa-Berral, Carlos
    Burguete, Javier
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [27] Experimental verification of the calculated dose for Stereotactic Radiosurgery with specially designed white polystyrene phantom
    Casar, B.
    Sarvari, A.
    [J]. 11TH MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2007, VOLS 1 AND 2, 2007, 16 (1-2): : 887 - 890
  • [28] Assessment of the dose distribution of Minibeam radiotherapy for lung tumors in an anthropomorphic phantom: A feasibility study
    Zeinali-Rafsanjani, Banafsheh
    Mosleh-Shirazi, Mohammad Amin
    Haghighatafshar, Mahdi
    Jalli, Reza
    Saeedi-Moghadam, Mahdi
    [J]. TECHNOLOGY AND HEALTH CARE, 2017, 25 (04) : 683 - 692
  • [29] Radiation dose evaluation of dental cone beam computed tomography using an anthropomorphic adult head phantom
    Wu, Jay
    Shih, Cheng-Ting
    Ho, Chang-hung
    Liu, Yan-Lin
    Chang, Yuan-Jen
    Chao, Max Min
    Hsu, Jui-Ting
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 287 - 291
  • [30] On the Quantification of the Dosimetric Accuracy of Collapsed Cone Convolution Superposition Algorithm for Small Lung Volumes Using IMRT
    Gutierrez, A.
    Calvo, O.
    Stathakis, S.
    Rassiah-Szegedi, P.
    Esquivel, C.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)