A collapsed-cone convolution/superposition dose computation algorithm for sliding window beams

被引:0
|
作者
Moreau, M [1 ]
Gibbons, J [1 ]
Bzdusek, K [1 ]
McNutt, T [1 ]
机构
[1] Philips Radiat Oncol Syst, Madison, WI USA
关键词
D O I
10.1118/1.1998657
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An algorithm was developed to compute the incident energy fluence array used when computing dose for a Sliding Window beam using the collapsed‐cone convolution/superposition (CCCS) dose computation algorithm. Method and Materials: The first step of a CCCS dose computation is the computation of the energy fluence array incident on the patient. The incident energy fluence array computation for a Sliding Window beam is the product of an opening density array (an integration over space‐time of the multi‐leaf collimator (MLC) leaf trajectories) and an open‐field energy fluence array. An opening density represents the fraction of the time a pixel is exposed during treatment (i.e. not covered by the MLC leaves). Models of the MLC leaf end shape, tongue‐and‐groove and interleaf leakage effects are used by the algorithm. For an MLC with rounded leaf ends, partial transmission based on the leaf end profile model is applied to the areas that are covered by the rounded tip of an MLC leaf. Transmission corresponding to half of the leaf thickness is applied to the areas that are covered by only the tongue or the groove of a leaf. Interleaf leakage is applied to the areas that are covered by the tongue of a leaf and the groove of an adjacent (or opposing adjacent) leaf. Linear accelerator head scatter effects are also taken into account by convolving the head scatter array by the total transmission array (opening density array + leaf transmission array). Results: The algorithm to compute dose for a Sliding Window was implemented and released in a commercial treatment planning system. Validation results showed point dose measurement accuracy of 4 % or better in the high dose areas. Conclusion: The Sliding Window CCCS dose computation algorithm meets the AAPM TG 53 dose accuracy criteria (Med Phys, 25, 1773–1829). © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2161 / 2161
页数:1
相关论文
共 50 条
  • [1] Collapsed-cone convolution superposition for improved accuracy of voxelwise dosimetry
    Graves, Stephen
    Tiwari, Ashok
    Sunderland, John
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [2] Minimum Segment Size for the Collapsed Cone Convolution Superposition Algorithm
    Buckey, C.
    Stathakis, S.
    Calvo, O.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Dosimetric test of collapsed cone convolution superposition algorithm in a heterogeneous media
    Oliveira e Silva, L. F.
    Mangueira, T. F.
    Dias, J. R.
    Avelino, S. R.
    [J]. EUROPEAN JOURNAL OF CANCER, 2013, 49 : S231 - S232
  • [4] A Study of Dose Calculation Based on Collapsed Cone Convolution Algorithm
    Zhou, Zhengdong
    Song, Wei
    [J]. 2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1331 - 1335
  • [5] Comparison of Collapsed Cone Convolution Superposition and Monte Carlo Dose Calculations for Spine SBRT Dose
    Parenica, H.
    Rembish, J.
    Saenz, D.
    Rasmussen, K.
    Kirby, N.
    Shi, Z.
    Li, Y.
    Fakhreddine, M.
    Crownover, R.
    Ha, C.
    Papanikolaou, N.
    Stathakis, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E163 - E164
  • [6] Photon dose calculations in homogeneous media for a treatment planning system using a collapsed cone superposition convolution algorithm
    Lydon, JM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06): : 1813 - 1822
  • [7] Commissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free beams
    Foster, Ryan D.
    Speiser, Michael P.
    Solberg, Timothy D.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (02): : 39 - 49
  • [8] The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy
    Carlsson, ÅK
    Ahnesjö, A
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2320 - 2332
  • [9] Accelerating Collapsed Cone Convolution/Superposition Dose Calculation On GPU Using Spatial Decomposition
    Xiao, K.
    Zhou, B.
    Hu, X. S.
    Chen, D. Z.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Evaluation of the Advanced Collapsed-cone Engine dose calculation algorithm for COMS eye plaques
    Morrison, H.
    Menon, G.
    Larocque, M.
    Weis, E.
    Sloboda, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S191 - S192