Photon dose calculations in homogeneous media for a treatment planning system using a collapsed cone superposition convolution algorithm

被引:22
|
作者
Lydon, JM [1 ]
机构
[1] E Melbourne Radiat Oncol Ctr, Melbourne, Vic 3002, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 06期
关键词
D O I
10.1088/0031-9155/43/6/031
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work reports on some of the initial tests that were conducted during the commissioning of a commercially available 3D treatment planning system. The system (Pinnacle 3.0d-u1) uses a collapsed cone implementation of the superposition convolution algorithm. Calculated and measured dose in homogeneous media were compared for wedged and unwedged fields for both symmetric and asymmetric collimator settings. Results show agreement of 2% or 2 mm in most cases. Where larger differences were found, further investigation was undertaken to explain these differences. These tests demonstrate the correct behaviour of the collapsed cone implementation of the algorithm in homogeneous media and its ability to characterize the beam.
引用
收藏
页码:1813 / 1822
页数:10
相关论文
共 50 条
  • [2] Photon Beam Modeling and Verification of Collapsed Cone Convolution Algorithm for Dose Calculation in a Radiation Treatment Planning System
    Jung, J.
    Cho, W.
    Lee, J.
    Kim, D.
    Kim, M.
    Suh, T.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3829 - 3829
  • [3] Dosimetric test of collapsed cone convolution superposition algorithm in a heterogeneous media
    Oliveira e Silva, L. F.
    Mangueira, T. F.
    Dias, J. R.
    Avelino, S. R.
    [J]. EUROPEAN JOURNAL OF CANCER, 2013, 49 : S231 - S232
  • [4] Experimental verification of convolution /superposition photon dose calculations for radiotherapy treatment planning
    Aspradakis, MM
    Morrison, RH
    Richmond, ND
    Steele, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (17): : 2873 - 2893
  • [5] The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy
    Carlsson, ÅK
    Ahnesjö, A
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2320 - 2332
  • [6] Comparison of Collapsed Cone Convolution Superposition and Monte Carlo Dose Calculations for Spine SBRT Dose
    Parenica, H.
    Rembish, J.
    Saenz, D.
    Rasmussen, K.
    Kirby, N.
    Shi, Z.
    Li, Y.
    Fakhreddine, M.
    Crownover, R.
    Ha, C.
    Papanikolaou, N.
    Stathakis, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E163 - E164
  • [7] Evaluation and Validation of a Set of Dosimetric and Geometric Accuracy Tests of the Collapsed Cone Convolution Superposition Dose Calculation Algorithm for the RefleXion Treatment Planning System
    Bassalow, R.
    Zaks, D.
    Maganti, S.
    Voronenko, Y.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E159 - E159
  • [8] Practical Implementation of a Collapsed Cone Convolution Algorithm for a Radiation Treatment Planning System
    Cho, Woong
    Suh, Tae-Suk
    Park, Jeong-Hoon
    Xing, Lei
    Lee, Jeong-Woo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (12) : 2073 - 2083
  • [9] Practical implementation of a collapsed cone convolution algorithm for a radiation treatment planning system
    Woong Cho
    Tae-Suk Suh
    Jeong-Hoon Park
    Lei Xing
    Jeong-Woo Lee
    [J]. Journal of the Korean Physical Society, 2012, 61 : 2073 - 2083
  • [10] A collapsed-cone convolution/superposition dose computation algorithm for sliding window beams
    Moreau, M
    Gibbons, J
    Bzdusek, K
    McNutt, T
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2161 - 2161